Tender for Supply, Installation, Commissioning And Testing Of Shell And Tube Type Heat Exchanger For 12.5m Va Areva Make Transformers Located At Electric Arc Furnace (eaf) Transformer Room. Required Specification: Capacity - 250kw, Type - Single Tube/wall, Mounting - Horizontal, Tube Material - Cu Ni 90 10, Other Moc - Cs Of Is 2062, Design Pressure (kg/cm2) Shell/tube - 5/5, Test Pressure (kg/cm2) Shell/tube - 7.5/7.5, Design Te Mperature Degree Celsius Shell/tube - 100/100, Oil Flow - 800 Lpm, Water Flow - 600 Lpm Of Thermo Engi Neers Private Limited Make Or Equivalent In All Respects. Note: - (1) Two Coat Epoxy Paint Will Be Applied On Outer Shell. (2) Supplied Heat-exchanger Should Be 1:1 Replacement Of Existing Heat-exchanger. So, No Modific Ation Should Be Required In The Existing System For The Installation Of The Supplied Heat-exchanger. However, If Any Minor Changes Are Required In Existing Foundation And Flange Fitment During Installation It Will Be Under Firm's Scop E. (3) The Drawing Attached Is For General Guidance Only. Manufacturer/supplier Should Study The Site Con Ditions Before Supply For The Fitment And Efficient Working Of The Product. Rwp Approved Drawing Number Rwp/m Ms/elec./01 Attached For Reference. 4) All Additional Parameters Which Are Not Mentioned In Description Or In Att Ached Drawing Should Be As Per Is 6088:1988 Standards Or Latest. No. Of Stage Inspection:1 (excluding Final Lot I Nspection). Description Of Stage-1 Inspection: As Per Approved Qap (as 100% Of Po Qty.) [ Warranty Period: 2 4 Months After The Date Of Delivery ] in Multi City - Bihar

Tender Details
Reference # :
36152326
Description :
Tenders for Supply, Installation, Commissioning And Testing Of Shell And Tube Type Heat Exchanger For 12.5m Va Areva Make Transformers Located At Electric Arc Furnace (eaf) Transformer Room. Required Specification: Capacity - 250kw, Type - Single Tube/wall, Mounting - Horizontal, Tube Material - Cu Ni 90 10, Other Moc - Cs Of Is 2062, Design Pressure (kg/cm2) Shell/tube - 5/5, Test Pressure (kg/cm2) Shell/tube - 7.5/7.5, Design Te Mperature Degree Celsius Shell/tube - 100/100, Oil Flow - 800 Lpm, Water Flow - 600 Lpm Of Thermo Engi Neers Private Limited Make Or Equivalent In All Respects. Note: - (1) Two Coat Epoxy Paint Will Be Applied On Outer Shell. (2) Supplied Heat-exchanger Should Be 1:1 Replacement Of Existing Heat-exchanger. So, No Modific Ation Should Be Required In The Existing System For The Installation Of The Supplied Heat-exchanger. However, If Any Minor Changes Are Required In Existing Foundation And Flange Fitment During Installation It Will Be Under Firm's Scop E. (3) The Drawing Attached Is For General Guidance Only. Manufacturer/supplier Should Study The Site Con Ditions Before Supply For The Fitment And Efficient Working Of The Product. Rwp Approved Drawing Number Rwp/m Ms/elec./01 Attached For Reference. 4) All Additional Parameters Which Are Not Mentioned In Description Or In Att Ached Drawing Should Be As Per Is 6088:1988 Standards Or Latest. No. Of Stage Inspection:1 (excluding Final Lot I Nspection). Description Of Stage-1 Inspection: As Per Approved Qap (as 100% Of Po Qty.) [ Warranty Period: 2 4 Months After The Date Of Delivery ]
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
NA
Doc. Cost :
NA
Important Dates
Due date :
06 Jun, 2024
Open date :
06 Jun, 2024
Publish date :
08 May, 2024
Location
Location :
Multi City - Bihar ( IN )
Connect us via What's Up