Web Analytics Made Easy - StatCounter

Tender for Corrigendum : Provision Of Power Supply Infra Items For Implementation Of Leh-chushul-thakung Itbp Link In Ba Leh. (rate Contract For 06 Sites) - Sub Head-i:- (dg Set), Supply Of Diesel Engine Alternator Set Suitable To Generate 5 Kva At Site Conditions, Cpcb-iv, Totally Enclosed Diesel Engine Of Suitable To Deliver Minimum 8.0 Bhp (at Ntp) , Factory Assembled And Factory Tested Single/multi Cylinder Air / Water Cooled Electric Start Ready To Use (rtu) Type, Housed In A Sound Proof Canopy With Manual Control Panel And Coupled With 5 Kva Single Phase, 230 Volts Alternator At 1500 / 3000 Rpm, 0.8 Lagging Power Factor, H-class Insulated Winding, Mounted On Rigid Ms Sheet Channel Base-frame Of Sturdy Design With Necessary Reinforcement And With In-built Fuel Tank Of Sheet Metal, Suitable Enough For Minimum 8 Hours Running Of Dg, Complete With Drain Valve, Air Vent, Inlet, Outlet Connections And Gauge. Complete With All Accessories, Battery, Engine Control Panel And Having Lube Oil Pressure Meter, Fuel Level Gauge, Voltmeter, Ammeter, Frequency Meter, Engine Rpm Meter Complete As Per Specifications Attached., Supplying , Installation, Testing And Commissioning Of Maintenance Free Chemical Earth Station As Per Latest Rdso Specifications Consisting Of :-a) Copper Bonded Steel Electrode Of 3 Meter Long, 17 Mm Dia With Copper Bonded Thickness Of Minimum 250 Microns And Ul Listed And Marked - 1no.b) Maintenance Free, Environmental Friendly, Mineral Compounds, Semi Soluble , Non Corrosive , Conductivity Improving Material Of Rdso Approved- 35 Kgc) Polyplastic , Heavy Duty, Weatherproof, Environmetle Free Earth Pit Chamber With Cover Size Approx. Top Dia 250mm, Bottom Dia 330 Mm And Height 260 Mm Heavy Duty Of 7 Ton Load Capacity, The Base Unit Should Have Knockouts For Interconnecting Of Strips- 1no., Providing And Fixing 32 Mm X 3 Mm G.i. Strip Direct In Ground Including Digging The Trench, Laying Of Strip And Refilling The Trench, Making Good The Damages, Connections Etc. As Required., Supplying Installation, Testing And Commissioning Of 32 A Rating, Double Pole, Side Handle Type Changeover Switch In Sheet Steel Enclosure Suitable For Operation On 240 V,1-phase, 50 Hz Ac Supply Including Interconnections , Complete As Required (bsnl Approved Makes)., Replacement / Supplying & Laying Of 2 X 6 Sq Mm Pvc Insulated, Pvc Sheathed Copper Conductor Armoured Cable Of 1.1kv Grade On Surface/wall I/c Making Connections, Testing Etc Complete As Reqd. (isi Make), Supplying And Fixing Of Fire Bucket Set( Set Of 3 Buckets) Of 9 Litre Capacity Coloured With Fire Red Paint And Written "fire On It Including Supplying And Fixing Suitable Size Ms Angle Iron Frame Suitable For 3 Buckets Having Hooks Etc. Including Fixing On Wall And Filling Soft Sand In Buckets Complete As Required., Supplying And Fixing Of Abc Type Fire Extinguishers Of 2 Kg (abc Powder Type Map-90) Complete With Delivery Hose, Squeeze Grip Release Valve, Locking Arrangement, Pressure Gauge, Operation Manual And Bracket Complete With Installation At Site With Suitable Bracket Complete As Required (isi), Acceptance Testing Of The 5 Kva Dg Set With Initial Testing After Commissioning Of Dg Set At Site For 4 Hrs In Presence Of Bsnl Representative And Final Acceptance Testing After The Initial Testing For 8 Hours On Full Load And 1 Hour On 10% Over Load At Site As Per Bsnl A/t Performa. All Resources (fuel, Artificial Load Arrangement, Skilled Manpower Etc.) Required For This Acceptance Testing Shall Be Arranged By Vendor., Sub Head - Ii: ( Solar Power Plant), Supplying, Installation, Testing And Commissioning Of Mono Perc Solar Pv Panels For 12.5 Kwp Solar Generation System Rating Complete As Required As Per The Attached Specifications., Supplying, Installation, Testing And Commissioning Of Battery Bank Of 180 V Suitable For 12.5kwp Solar Pv System Comprising Of 90 Nos.. 2v - 200 Ah Rating Vrla Batteries, Battery Rack, Protections, Dc Distribution Board, Suitable Teflon Cabling For Inte in Leh - Jammu And Kashmir

Tender Details
Reference # :
38354542
Description :
Tenders for Corrigendum : Provision Of Power Supply Infra Items For Implementation Of Leh-chushul-thakung Itbp Link In Ba Leh. (rate Contract For 06 Sites) - Sub Head-i:- (dg Set), Supply Of Diesel Engine Alternator Set Suitable To Generate 5 Kva At Site Conditions, Cpcb-iv, Totally Enclosed Diesel Engine Of Suitable To Deliver Minimum 8.0 Bhp (at Ntp) , Factory Assembled And Factory Tested Single/multi Cylinder Air / Water Cooled Electric Start Ready To Use (rtu) Type, Housed In A Sound Proof Canopy With Manual Control Panel And Coupled With 5 Kva Single Phase, 230 Volts Alternator At 1500 / 3000 Rpm, 0.8 Lagging Power Factor, H-class Insulated Winding, Mounted On Rigid Ms Sheet Channel Base-frame Of Sturdy Design With Necessary Reinforcement And With In-built Fuel Tank Of Sheet Metal, Suitable Enough For Minimum 8 Hours Running Of Dg, Complete With Drain Valve, Air Vent, Inlet, Outlet Connections And Gauge. Complete With All Accessories, Battery, Engine Control Panel And Having Lube Oil Pressure Meter, Fuel Level Gauge, Voltmeter, Ammeter, Frequency Meter, Engine Rpm Meter Complete As Per Specifications Attached., Supplying , Installation, Testing And Commissioning Of Maintenance Free Chemical Earth Station As Per Latest Rdso Specifications Consisting Of :-a) Copper Bonded Steel Electrode Of 3 Meter Long, 17 Mm Dia With Copper Bonded Thickness Of Minimum 250 Microns And Ul Listed And Marked - 1no.b) Maintenance Free, Environmental Friendly, Mineral Compounds, Semi Soluble , Non Corrosive , Conductivity Improving Material Of Rdso Approved- 35 Kgc) Polyplastic , Heavy Duty, Weatherproof, Environmetle Free Earth Pit Chamber With Cover Size Approx. Top Dia 250mm, Bottom Dia 330 Mm And Height 260 Mm Heavy Duty Of 7 Ton Load Capacity, The Base Unit Should Have Knockouts For Interconnecting Of Strips- 1no., Providing And Fixing 32 Mm X 3 Mm G.i. Strip Direct In Ground Including Digging The Trench, Laying Of Strip And Refilling The Trench, Making Good The Damages, Connections Etc. As Required., Supplying Installation, Testing And Commissioning Of 32 A Rating, Double Pole, Side Handle Type Changeover Switch In Sheet Steel Enclosure Suitable For Operation On 240 V,1-phase, 50 Hz Ac Supply Including Interconnections , Complete As Required (bsnl Approved Makes)., Replacement / Supplying & Laying Of 2 X 6 Sq Mm Pvc Insulated, Pvc Sheathed Copper Conductor Armoured Cable Of 1.1kv Grade On Surface/wall I/c Making Connections, Testing Etc Complete As Reqd. (isi Make), Supplying And Fixing Of Fire Bucket Set( Set Of 3 Buckets) Of 9 Litre Capacity Coloured With Fire Red Paint And Written "fire On It Including Supplying And Fixing Suitable Size Ms Angle Iron Frame Suitable For 3 Buckets Having Hooks Etc. Including Fixing On Wall And Filling Soft Sand In Buckets Complete As Required., Supplying And Fixing Of Abc Type Fire Extinguishers Of 2 Kg (abc Powder Type Map-90) Complete With Delivery Hose, Squeeze Grip Release Valve, Locking Arrangement, Pressure Gauge, Operation Manual And Bracket Complete With Installation At Site With Suitable Bracket Complete As Required (isi), Acceptance Testing Of The 5 Kva Dg Set With Initial Testing After Commissioning Of Dg Set At Site For 4 Hrs In Presence Of Bsnl Representative And Final Acceptance Testing After The Initial Testing For 8 Hours On Full Load And 1 Hour On 10% Over Load At Site As Per Bsnl A/t Performa. All Resources (fuel, Artificial Load Arrangement, Skilled Manpower Etc.) Required For This Acceptance Testing Shall Be Arranged By Vendor., Sub Head - Ii: ( Solar Power Plant), Supplying, Installation, Testing And Commissioning Of Mono Perc Solar Pv Panels For 12.5 Kwp Solar Generation System Rating Complete As Required As Per The Attached Specifications., Supplying, Installation, Testing And Commissioning Of Battery Bank Of 180 V Suitable For 12.5kwp Solar Pv System Comprising Of 90 Nos.. 2v - 200 Ah Rating Vrla Batteries, Battery Rack, Protections, Dc Distribution Board, Suitable Teflon Cabling For Inte
Ownership :
Sector :
Tender Values
Value :
9,315,442
EMD :
186,309
Doc. Cost :
1,180
Important Dates
Due date :
06 Jan, 2025
Open date :
10 Jan, 2025
Publish date :
26 Nov, 2024
Location
Location :
Leh - Jammu And Kashmir ( IN )
Connect us via What's Up