Description :
Tenders for Corrigendum : Supply Of Control Valves For Lara Singrauli And Talcher Projects - Lara-cv-asv-8, Dea Pegging From Aux. Steam Header , Lara-cv-crhv-6, Dea Pegging From Crh Line , Lara-cvcdv-25, Low Load Condensate Control , Lara-cvcdv-39, Gsc Min. Flow Recirculation , Lara-cv-cdv65, Cep-a Min. Flow Recirculation , Lara-cv-cdv-67, Cep-b Min. Flow Recirculation , Lara-cv-cdv-69, Cep-c Min. Flow Recirculation , Lara-cv-cdv-43, Excess Dump Control , Lara-cv-cdv-72, Condensate For Valve Gland Sealing And Flash Tank , Lara-cv-cdv84, Condensate Spray For Flash Tank , Lara-cv-cdv94, Condensate Spray For Unit Flash Tank , Lara-cvdrv-53, Hph-9a Normal Drain To Hph-8a , Lara-cv-drv59, Hph-9b Normal Drain To Hph-8b , Lara-cv-drv-56, Hph-9a Alt Drain To Flash Tank , Lara-cv-drv-62, Hph9b Alt Drain To Flash Tank , Lara-cv-drv-2, Hph-8a Normal Drain To Hph-7a , Lara-cv-drv-8, Hph-8b Normal Drain To Hph-7b , Lara-cv-drv-5, Hph-8a Alt Drain To Flash Tank , Lara-cv-drv-11, Hph-8b Alt Drain To Flash Tank , Lara-cv-drv-15, Hph-7a Normal Drain To Deaerator , Lara-cv-drv-22, Hph-7b Normal Drain To Deaerator , Lara-cv-drv-18, Hph-7a Alt Drain To Flash Tank , Lara-cv-drv-25, Hph-7b Alt Drain To Flash Tank , Lara-cv-drv-82, Lph-5 Normal Drain To Lph-4 , Lara-cv-drv-85, Lph-5 Alt. Drain To Flash Tank-b , Lara-cv-drv-65, Lph-4 Normal Drain To Lph-3 , Lara-cv-drv-68, Lph-4 Alt. Drain To Flash Tank-b , Lara-cv-drv-77, Drip Pump Discharge Control , Lara-cv-drv-31, Lph-3 Alt. Drain To Flash Tank-b , Lara-cv-drv-48, Deaerator Overflow To Flash Tank-b , Lara-cv-dmv-43, Normal Dm Mu To Hotwell , Lara-cv-dmv-78, Emergency Dm Mu To Hotwell , Lara-cv-asv-16, Drain Of Aux Steam From Existing Unit Header To Unit Flash Tank , Lara-cvdmcwsg12, Dmcw System For Sg Aux , Lara-cvdmcw18, Dmcw System For Tg Aux , Lara- One Fourth Inch Ss Tubing -12 Meter For Each Tag , Lara- Ss Fittings For Connection To Air Filter Regulator- For Each Tag , Lara- Ss Fittings For Connection To Air Lock Relayfor Each Tag , Lara- Ss Fittings For Connection To Ia Header Isolation Valve - For Each Tag , Lara- Ss Equal Tee - For Each Tag , Lara- Ss Half Inch Npt M X One Fourth Inch Od Tube Connector- For Each Tag , Lara- Commissioning Spares Gaskets And Gland Packing Set For Each Valve , Lara- Valve Diagnostic And Configuration Software , Lara- Cv Test Charges , Lara- Mandatory Spares- Pneumatic And Electro Hydraulic Actuator Assembly Or Equivalent Item Applicable For Selected Actuator Type Shall Be Provided, 1 No. Of Each Type Model And Rating , Lara- Mandatory Spares- Diaphragms, O Rings, Seals Etc.- 5 Nos. Of All Types Make Etc. , Lara- Mandatory Spares- Solenoid Valves If Applicable - 1 No. Of Each Type , Lara- Mandatory Spares- Smart Positioners Complete Unit And Accessories Link Assembly - 2 Nos. Of Each Type, Model And Rating , Lara- Mandatory Spares- Pneumatic Air Filter Or Regulator- 2 Nos. Of Each Type, Make Rating Etc. , Laramandatory Spares- Air Lock Relays- 1 No. Of Each Type, Model And Rating , Lara- Mandatory Spares- Valve Trim - Including Cage, Plug, Stem, Seat Rings, Guide Bushings Etc. - 1 Set For Each Type,class,size Of Control Valve , Lara- Mandatory Spares- Gland Packing- 5 Sets , Lara- Mandatory Sparesgaskets- 5 Sets , Lara- Mandatory Spares- Cep Recirculation Valve Trim Which Includes Spindle With Cone, Seat Ring, Guide Bush, Cage- 1 Set , Lara- Mandatory Spares- Cep Recirculation Valve Soft Parts I.e. Gland Packing, Seals, Orings, Gaskets Etc.- 3 Sets , Lara- Mandatory Spares- Ss Fittings For Connection To Air Filter Regulator- For Each Tag- 100 Nos. Of Each Type , Lara- Mandatory Spares- Ss Fittings For Connection To Air Lock Relay- For Each Tag100 Nos. Of Each Type , Lara- Mandatory Spares- Ss Fittings For Connection To Ia Header Isolation Valve- For Each Tag- 100 Nos. Of Each Type , Lara- Mandatory Spares- Ss Equal Tee- For Each Tag- 100 Nos. Of Each Type , Lara- Mandatory Spares- Pneumatic Air Filter Or Regulator- 20 Nos. Of Each Type And Model , Laramandatory Spares- V