Web Analytics Made Easy - StatCounter

Tender for Purchase Of Equipment, Configuration Design Multichannel Electrochemical Workstation Containing A Minimum Of 2 Channels With Impedance System Should Have A Minimum Of Two Potentiostat/galvanostat Modules In Single Cabinet To Operate Independently And Simultaneously1. General Description Chassis: Multichannel Single Chassis A Minimum Of Two Channels Should Have Electrochemical Impedance Spectroscopy (eis) Measurements2. Specification For Channels Cell Connection: 4 (we, S, Ce And Re) Channels Required: A Minimum Of 2 Channels Must Be Equipped With Eis Facility Compliance Voltage: 20 V Or Better Per Channel Applied Voltage: 10 V Or Better Per Channel Maximum Output Current: 400 Ma Or Better Current Ranges: 10 Na To 100 Ma Or Better Resolution Of Applied/measured Potential: 3 V Or Better Voltage Accuracy: 0.1 % Of Full-scale Range Or 3 V Or Better Measured Current Resolution: 800 Fa On Lowest Current Range Or Better Frequency Range: 10 Hz To 1 Mhz Or Better Impedance Accuracy/resolution: 1%& 1 At 1hz Or 0.003% Gain Bandwidth Range Of Amplifier: 1 Mhz Or Better Bandwidth Of Electrometer: 1mhz Or Better Input Bias Current: 20 Pa Or Better Possibility To Upgrade To High Current Up To 10 A Or Better Using Booster Provision To Connect External Devices Or Use Optional Accessories Internal Resistance Determination Acquisition Rate: 1000,000 Samples/second3. Complete Software With The Following Specification Software Should Be Capable Of Supporting A Wide Variety Of Electrochemical Techniques Especially Mentioned Below.4. Electrochemical Impedance Two Channel Should Have Eis Measurement Facility With Frequency Range 10 Hz To 1 Mhz Or Better5. Desktop Computer Pc I5 (or Higher), 8gb Ram, 1tb Hdd, 22" Led Monitor (or Higher), Ssd: 512 Gb, Windows 10 Os (or Higher), Wired Keyboard And Mouse. Should Be Procured From India6. Optional Accessories7. General Terms And Conditionswarranty: 3 Years Manufacturer S Warranty Certificate. Vendor Should Be An Authorized Provider Of Sophisticated High-precision Potentiostat/galvanostat Systems For Past 15 Years Or More With: A Proven Track Record In Multiple Countries And National Institutes Standard Quality Certifications Such (iso 9001) 5+ Past Installations Of Similar Systems In India. Compliance Statement Should Be Enclosed With The Quotation. Please Provide Cost Split Up Of Each Accessory. Mention The Cost Of Optional Accessories Separately. in Coimbatore - Tamil Nadu

Tender Details
Reference # :
39076322
Description :
Tenders for Purchase Of Equipment, Configuration Design Multichannel Electrochemical Workstation Containing A Minimum Of 2 Channels With Impedance System Should Have A Minimum Of Two Potentiostat/galvanostat Modules In Single Cabinet To Operate Independently And Simultaneously1. General Description Chassis: Multichannel Single Chassis A Minimum Of Two Channels Should Have Electrochemical Impedance Spectroscopy (eis) Measurements2. Specification For Channels Cell Connection: 4 (we, S, Ce And Re) Channels Required: A Minimum Of 2 Channels Must Be Equipped With Eis Facility Compliance Voltage: 20 V Or Better Per Channel Applied Voltage: 10 V Or Better Per Channel Maximum Output Current: 400 Ma Or Better Current Ranges: 10 Na To 100 Ma Or Better Resolution Of Applied/measured Potential: 3 V Or Better Voltage Accuracy: 0.1 % Of Full-scale Range Or 3 V Or Better Measured Current Resolution: 800 Fa On Lowest Current Range Or Better Frequency Range: 10 Hz To 1 Mhz Or Better Impedance Accuracy/resolution: 1%& 1 At 1hz Or 0.003% Gain Bandwidth Range Of Amplifier: 1 Mhz Or Better Bandwidth Of Electrometer: 1mhz Or Better Input Bias Current: 20 Pa Or Better Possibility To Upgrade To High Current Up To 10 A Or Better Using Booster Provision To Connect External Devices Or Use Optional Accessories Internal Resistance Determination Acquisition Rate: 1000,000 Samples/second3. Complete Software With The Following Specification Software Should Be Capable Of Supporting A Wide Variety Of Electrochemical Techniques Especially Mentioned Below.4. Electrochemical Impedance Two Channel Should Have Eis Measurement Facility With Frequency Range 10 Hz To 1 Mhz Or Better5. Desktop Computer Pc I5 (or Higher), 8gb Ram, 1tb Hdd, 22" Led Monitor (or Higher), Ssd: 512 Gb, Windows 10 Os (or Higher), Wired Keyboard And Mouse. Should Be Procured From India6. Optional Accessories7. General Terms And Conditionswarranty: 3 Years Manufacturer S Warranty Certificate. Vendor Should Be An Authorized Provider Of Sophisticated High-precision Potentiostat/galvanostat Systems For Past 15 Years Or More With: A Proven Track Record In Multiple Countries And National Institutes Standard Quality Certifications Such (iso 9001) 5+ Past Installations Of Similar Systems In India. Compliance Statement Should Be Enclosed With The Quotation. Please Provide Cost Split Up Of Each Accessory. Mention The Cost Of Optional Accessories Separately.
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
24,000
Doc. Cost :
NA
Important Dates
Due date :
08 Feb, 2025
Open date :
10 Feb, 2025
Publish date :
24 Jan, 2025
Location
Location :
Coimbatore - Tamil Nadu ( IN )
Connect us via What's Up