Web Analytics Made Easy - StatCounter

Tender for Supply Of Title 1 To 12 - Providing, Installing, Testing And Commissioning Of silent Type Diesel Generating Setcomplying With Cpcb Iv+ Alongwith Having Prime Power Rating Of 250 Kva, 415 Volts At 1500rpm, 0.8 Lagging Power Factor At 415v Suitable For 50 Hz, 3 Phase System & For 0.85 Loadfactor Including Credit For Dismantle Material Of Old Unserviceble Dg Set And Consisting Of Thefollowings , Fabricating, Installing, Testing & Commissioning Of Automatic Mains Failure Control Suitable For250 Kva Silent Type Dg Set With Credit For Dismantle Material Of Amf Complete With Relays,timers, Set Of Cts For Metering & Protection And Energy Analyser To Indicate Currents, Phase Andline Voltages, Frequency, Power Factor, Kwh, Kvarh & Provision For Overload, Short Circuit,earth Fault, Under Frequency, Control Cabling From Amf Panel To Diesel Engine And Elsewhere Ifrequired, All Complete And Interlocking Including The Followin , Supplying And Fixing Exhaust Gas Piping Of Suitable Dia. Welded Black Ms, B Class Pipeconforming To Is:3589 Cut To Required Lengths And Installed With Necessary Bends, Supports Andclamps, Anti-vibration Mountings, Insulation Of Exhaust System With Mineral Wool/rockwool, 50mm Thick Wiremesh & Aluminum Cladding Etc., As Required As Per Specification , Supply And Laying Of Of 3.5 X 185 Sq Mm Sizes Of Xlpe Insulated Pvc Sheathed Aluminiumconductor Armoured Power Cable Of 1.1 Kv Grade Confirming To Is:7098 (part 1) Includingmaking Connection With Suitable Size Of Aluminum Lugs, Laying On Wall/surface, Testing Etc. Asrequired. , Supply, Installation, Commissioning & Testing Of Complete Set Of Maintenance Free Chemicalearthing With Copper Bonded Electrode suitable Dia & Length 50 X 6 Mm Pure Copper Internalstrip With Suitable Terminal, Ground Enhancement Material / Back Fill Compound / Groundingcompound Of Permanent & Maintenance Free Nature. (50 Kg. For Each Earth Pit) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. Asrequired. , Sitc Of Clean Agent Based Tube Fire Suppression System 2 Kg 10 Mtr. Heat Sensing Ul Listedtube With Ul Listed Fk5-1-12 Clean Agent Gas , Supply & Laying Of 10 Core X 2.5 Sq Mm Copper Conductor Control Cable Of Insulation:-xlpe(cross Linked Polyethylene / Pvc), Inner Sheath:- Pvc (polyvinyl Chloride) St-2 / Frls,armouring:- Galvanized Steel Flat Strip Or Round Wire, Outer Sheath:-pvc (polyvinyl Chloride)st-2 / Frls I/c Making Connection, Testing, Laying On Wall/surface & Commisioning Etc Completeas Required , Supply & Laying Of 3 Core X 2.5 Sq Mm Copper Conductor Control Cable Of Insulation:-xlpe(cross Linked Polyethylene / Pvc), Inner Sheath:- Pvc (polyvinyl Chloride) St-2 / Frls,armouring:- Galvanized Steel Flat Strip Or Round Wire, Outer Sheath:-pvc (polyvinyl Chloride)st-2 / Frls I/c Making Connection, Testing, Laying On Wall/surface & Commisioning Etc Completeas Required , Supplying And Making End Termination Of Size 3 X 185 Sq. Mm (57mm) With Brass Compressiongland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpealuminium Conductor Cable Of 1.1 Kv Grade As Required. , 1 Supply Installation Testing And Commissioning Of Avm Pads Ecs 25x400 Suitable For Dg Set. 1 , Supply Of High Speed Diesel For Operation Of Dg Set I/c Cartage Filling Etc. Complete As Require in Delhi - Delhi

Tender Details
Reference # :
39383830
Description :
Tenders for Supply Of Title 1 To 12 - Providing, Installing, Testing And Commissioning Of silent Type Diesel Generating Setcomplying With Cpcb Iv+ Alongwith Having Prime Power Rating Of 250 Kva, 415 Volts At 1500rpm, 0.8 Lagging Power Factor At 415v Suitable For 50 Hz, 3 Phase System & For 0.85 Loadfactor Including Credit For Dismantle Material Of Old Unserviceble Dg Set And Consisting Of Thefollowings , Fabricating, Installing, Testing & Commissioning Of Automatic Mains Failure Control Suitable For250 Kva Silent Type Dg Set With Credit For Dismantle Material Of Amf Complete With Relays,timers, Set Of Cts For Metering & Protection And Energy Analyser To Indicate Currents, Phase Andline Voltages, Frequency, Power Factor, Kwh, Kvarh & Provision For Overload, Short Circuit,earth Fault, Under Frequency, Control Cabling From Amf Panel To Diesel Engine And Elsewhere Ifrequired, All Complete And Interlocking Including The Followin , Supplying And Fixing Exhaust Gas Piping Of Suitable Dia. Welded Black Ms, B Class Pipeconforming To Is:3589 Cut To Required Lengths And Installed With Necessary Bends, Supports Andclamps, Anti-vibration Mountings, Insulation Of Exhaust System With Mineral Wool/rockwool, 50mm Thick Wiremesh & Aluminum Cladding Etc., As Required As Per Specification , Supply And Laying Of Of 3.5 X 185 Sq Mm Sizes Of Xlpe Insulated Pvc Sheathed Aluminiumconductor Armoured Power Cable Of 1.1 Kv Grade Confirming To Is:7098 (part 1) Includingmaking Connection With Suitable Size Of Aluminum Lugs, Laying On Wall/surface, Testing Etc. Asrequired. , Supply, Installation, Commissioning & Testing Of Complete Set Of Maintenance Free Chemicalearthing With Copper Bonded Electrode suitable Dia & Length 50 X 6 Mm Pure Copper Internalstrip With Suitable Terminal, Ground Enhancement Material / Back Fill Compound / Groundingcompound Of Permanent & Maintenance Free Nature. (50 Kg. For Each Earth Pit) , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. Asrequired. , Sitc Of Clean Agent Based Tube Fire Suppression System 2 Kg 10 Mtr. Heat Sensing Ul Listedtube With Ul Listed Fk5-1-12 Clean Agent Gas , Supply & Laying Of 10 Core X 2.5 Sq Mm Copper Conductor Control Cable Of Insulation:-xlpe(cross Linked Polyethylene / Pvc), Inner Sheath:- Pvc (polyvinyl Chloride) St-2 / Frls,armouring:- Galvanized Steel Flat Strip Or Round Wire, Outer Sheath:-pvc (polyvinyl Chloride)st-2 / Frls I/c Making Connection, Testing, Laying On Wall/surface & Commisioning Etc Completeas Required , Supply & Laying Of 3 Core X 2.5 Sq Mm Copper Conductor Control Cable Of Insulation:-xlpe(cross Linked Polyethylene / Pvc), Inner Sheath:- Pvc (polyvinyl Chloride) St-2 / Frls,armouring:- Galvanized Steel Flat Strip Or Round Wire, Outer Sheath:-pvc (polyvinyl Chloride)st-2 / Frls I/c Making Connection, Testing, Laying On Wall/surface & Commisioning Etc Completeas Required , Supplying And Making End Termination Of Size 3 X 185 Sq. Mm (57mm) With Brass Compressiongland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpealuminium Conductor Cable Of 1.1 Kv Grade As Required. , 1 Supply Installation Testing And Commissioning Of Avm Pads Ecs 25x400 Suitable For Dg Set. 1 , Supply Of High Speed Diesel For Operation Of Dg Set I/c Cartage Filling Etc. Complete As Require
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
109,000
Doc. Cost :
NA
Important Dates
Due date :
11 Mar, 2025
Open date :
11 Mar, 2025
Publish date :
18 Feb, 2025
Location
Location :
Delhi - Delhi ( IN )
Connect us via What's Up