Description :
Tenders for Providing Of Is Required To Be Carried Out On Gpu 90 Kva Statcon An-32 S No. 10772 (uid No. 13/gpu-90(f)/i/0044) Of 49 Sqn To Maintained Its Serviceability Through Lrp. (a) (b) Rotary Switch Is Required To Be Replaced With New One. Rpm/hour Meter To Be Replaced With New One And Setting To Be Carried Out. (c) Lcd Display & Keypad To Be Replaced With New One And Necessary Configuration As Per Specification To Be Reset. (d) Charging Contractor To Be Replaced And Charging Circuit To Be Repaired. (e) Relay 24v 3 C/o & 230v 3 C/o To Be Replaced With New One. (1) Bleeder Resistance Wom Out, Required To Be Replaced With New One. (g) Transducer Assy Required To Be Replaced With New One And Required Setting Of Voltage And Current To Be Reset. (h) Functional Check Of Gpu On Load To Be Carried Out After Repair