Web Analytics Made Easy - StatCounter

Tender for One Coach Set Of Roof, Sidewall And End Wall For Amrit Bharat Lws/pp2 (754) 1. Roof Ass Embly To Drg No 75416001, Alt 'nil' - 1 No, 2. End Roof Assembly To Drg No 97216008, Alt 'a' - 2 Nos 3. Side Wall To Drg No 75414001, Alt 'a' - 1 No 4. End Wall To Drg No 75415001, Alt 'b' - 2 Nos Welding Pin Arrangement To Drg No 58110037, Alt 'nil' Had To Be Assembled On Roof And Sidewall. The Firm Shall Ful Fil The Requirement As Per Icf//md/specn.200, Issue Status01, Rev 04 With Amendment No 01. The Firm Shall Fulfil The Requirement As Per Icf/md/spec-315,issue Status-01,rev.00 Firm Ha S To Supply Roof And Sidewall Without Applying Etch Primer And The Firm Has To Apply Etch Primer On Roof And Sidewall In Icf After Shell Assembly. To Be Supplied In Coach Set Special Condition : This Is A New Build And There Will Be Minor Changes In Drawing. Firm Shall Obtain Final Drawing F Rom Icf Before Start Of Manufacturing. Packing For Roof And Side Wall As Per Icf/j&t/mis C-2201, Alt "e" Safety Instruction As Per Icf/j&t/sk-1867, Alt 'nil' Packing For End Wall As P Er Drg.icf/j&t/sk 1809, Alt "a".[safety Item ] in Multi City - Multi State

Tender Details
Reference # :
39549593
Description :
Tenders for One Coach Set Of Roof, Sidewall And End Wall For Amrit Bharat Lws/pp2 (754) 1. Roof Ass Embly To Drg No 75416001, Alt 'nil' - 1 No, 2. End Roof Assembly To Drg No 97216008, Alt 'a' - 2 Nos 3. Side Wall To Drg No 75414001, Alt 'a' - 1 No 4. End Wall To Drg No 75415001, Alt 'b' - 2 Nos Welding Pin Arrangement To Drg No 58110037, Alt 'nil' Had To Be Assembled On Roof And Sidewall. The Firm Shall Ful Fil The Requirement As Per Icf//md/specn.200, Issue Status01, Rev 04 With Amendment No 01. The Firm Shall Fulfil The Requirement As Per Icf/md/spec-315,issue Status-01,rev.00 Firm Ha S To Supply Roof And Sidewall Without Applying Etch Primer And The Firm Has To Apply Etch Primer On Roof And Sidewall In Icf After Shell Assembly. To Be Supplied In Coach Set Special Condition : This Is A New Build And There Will Be Minor Changes In Drawing. Firm Shall Obtain Final Drawing F Rom Icf Before Start Of Manufacturing. Packing For Roof And Side Wall As Per Icf/j&t/mis C-2201, Alt "e" Safety Instruction As Per Icf/j&t/sk-1867, Alt 'nil' Packing For End Wall As P Er Drg.icf/j&t/sk 1809, Alt "a".[safety Item ]
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
NA
Doc. Cost :
NA
Important Dates
Due date :
16 Apr, 2025
Open date :
16 Apr, 2025
Publish date :
03 Mar, 2025
Location
Location :
Multi City - Multi State ( IN )
Connect us via What's Up