Description :
Tenders for High Frequency X-ray Machine-, , , High Frequency X-ray Machine Suitable For General Radiography., , X-ray Generator:, , High Frequency X-ray Generator Having Frequency Of 50khz Should Be Provided., , Oil Filled Based Generator For High Dielectric Strength, Better Heat Dissipation, And Easy Service Stability., , Power Output Of Generator Should Be 40 Kw., , Radiographic Kv Range Should Be 40 To 125kv., , Ma Range (rad.): Upto 500ma., , Exposure Time (rad.): 2ms To 2sec., , Mas Range (rad.): 1 To 200mas., , Control:, , A Very Compact, Soft Feather Touch Control Panel Having Following Functions & Indications Should Be Provided. The Panel Can Be Supplied In Floor Mount With Spill Proof Design., , Following Features Should Be Available On The Control Panel., , Machine On/off Switch., , Digital Display Of Kv & Mas., , Kv & Mas Increase And Decrease Switches., , Tube Focal Spot Selection Switch., , Ready And X-ray On Switch With Indicators, , Bucky Selection Switch., , Self Diagnostic Programme With Indicators For Earth Fault Error, Kv Error, Filament Error & Tube's Thermal Overload., , Anatomical Preprogrammed Parameters Of Human Anatomy Should Be Available To Select Exposure Parameters Based On Body Part, Examination View And Size Of The Patient., , Anatomical Programming Up To 200 Programmes Or More, , A Dual Action Hand Switch With Retractable Cord Should Be Provided For Radiation Protection Of Operator., , X-ray Tube:, , One No. Dual Focus Rotating Anode X-ray Tube Thermally Protected., , Anode Heat Storage Capacity Of Tube Should Be 140 Khu., , One Pair Of 8-meter H.v. Cable., , One No. Collimator With Auto Shut Off Facility, Should Be Provided., , Hv Tank:, , A Very Compact H.v. Tank Filled With High Dielectric Transformer Oil Should Be Provided. The H.v. Tank Should Contain H.v. Transformer, Filament Transformers, H.v. Rectifiers & H.v. Cable Receptacles., , Tube Stand:, , Floor Mounted Ceiling Free Tube Stand With Counter Balanced Movements & With Easy Installation At Site., , Manual Movements With Electromagnet Locks In Longitudinal, Transverse & Vertical Movements Are Provided With Release Switches On Electromagnet Panel Mounted On Tube Collimator Assembly., , Tilto Meter On Electromagnet Panel To Show Tube Angle Position., , Continuous Tube Rotation Around Horizontal Axis With Lock, , F. Table:, , Floatex Table With 4-way Movement Of The Table Top I.e. Along X Axis And Y Axis Is To Be Provided. Longitudinal Movement Of Tabletop Is 500mm Or More & Transverse Movement Is 180mm Or More., , The Table Should Consists Of Bucky Motorized Reciprocating Grid Of Ratio 8:1 - 85 Lines/inch., , The Bucky Should Be Locked At Any Desired Length Position By An Electromagnetic Lock., , The Tabletop Should Be Made Of Low Radiation Absorption, Waterproof Material., , Table Accessories Like Stainless Steel Cassette Tray, Compression Band Is To Be Provided., , G. Vertical Bucky Stand:-, , Vertical Bucky Stand With Oscillating Grid Of Ratio 8:1, 85 Lines / Inch Is Provided., , The Bucky Moves Up & Down & Is Equipped With A Stainless Steel Cassette Tray., , The Stand Is Floor-mounted Type & Can Accommodate Cassettes Up To 14" X 17". The Bucky Is Tilted In 6 Steps Of 15 Degree Angle Each For Various Radiographs., , Vbs Should Have Provision For Without Grid Exposure., , Power Requirement: The Unit Should Be, , Operable On 3 Phase, 400 Volts Ac 50hz With Line Resist Less Than 0.2 Ohms. Line Regulation 10%., , Other Requirements:, , The Company Should Be Iso & Icmed Certified Company., , The Unit Should Be Approved By Aerb., , The Company Should Be European Ce Certified From Notified Body., , The Equipment Should Have Import/manufacturing, ,