Description :
Tenders for Implementation Of Lt Auxiliary Items For Smart Metering Works In Sikkim Under Revamped Reforms-based And Results-linked, Distribution Sector Scheme - Through Main Service Distribution Box, Smc Main Service Distribution Box (msdb) For Ug (10% Of Msdbs For 17652 Consumers- 6 Per Msdb), Smc Main Service Distribution Box (msdb) For Over Head (1 Msdb Per 6 Consumers For 50% Consumers), 4 Core 25 Sq Mm Xlpe Cable From Oh Line To Msdb [@ 2 Meter Per Msdb], Piercing Connectors From Lt Ab Cable (for 10587 Msdbs @4 Per Msdb), Dt Cable, 4cx35 Sq Mm Cable,1.1kv Grade, Xlpe Insulated, Armoured, Frls Type For 16kva, 25kva Xmer [1,564 Dts @ 6 Meter Per Dtr], 4cx50 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated, Armoured, Frls Type For 50kva And 63kva Xmer [686 Dts @ 6 Meter Per Dtr], 4x1c*120 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated, Armoured Frls Type For 100kva Xmer [277 Dts @ 6 Meter Per Dtr], 4cx185 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated, Armoured Frls Type For 150kva -200kva Xmer [203 Dts. @ 6 Meter Per Dtr], 2rx4cx120 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated Armoured, Frls Type For 250kva - 315 Kva Xmer [222 Dts @ 6 Meter Per Dtr], 2rx4cx240 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated Armoured, Frls Type For 400kva - 500kva Xmer [196 Dts @ 6 Meter Per Dtr], 2rx4cx300 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated Armoured, Frls Type For 630kva Xmer [9 Dts @ 6 Meter Per Dtr], 2rx4cx400 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated Armoured, Frls Type For 700kva - 800kva Xmer [19 Dts @ 6 Meter Per Dtr], 2rx4cx630 Sq Mm Cable, 1.1kv Grade, Xlpe Insulated Armoured, Frls Type For 1000kva Xmer [53 Dts @ 6 Meter Per Dtr], Sundry Items Such As Lugs, Tapes Etc. For Proper Terminations/ Ct Connections Etc., Aluminum Thimble 35 Sq Mm For Dt Meter [1,564 Dts @ 8 Nos.per Dtr], Aluminum Thimble 50 Sq Mm For Dt Meter [686 Dts @ 8 Nos. Per Dtr], Aluminum Thimble 120 Sq Mm For Dt Meter [277 Dts @ 8 Nos. Per Dtr, 222 Dts @ 16 Nos. Per Dtr For Double Run Cable], Aluminum Thimble 185 Sq Mm For Dt Meter [203 Dts. @ 8 Nos. Per Dtr, For Double Run Cable], Aluminum Thimble 240 Sq Mm For Dt Meter [196 Dts @16 Nos. Per Dtr For Double Run Cable], Aluminum Thimble 300 Sq Mm For Dt Meter [9 Dts @16 Nos. Per Dtr For Double Run Cable], Aluminum Thimble 400 Sq Mm For Dt Meter [19 Dts @ 16 Nos. Per Dtr For Double Run Cable], Aluminum Thimble 630 Sq Mm For Dt Meter [53 Dts @ 16 Nos. Per Dtr For Double Run Cable], L.t. Distribution Board, Ltdb 63 A, Ltdb 100 A, Ltdb 200 A, Ltdb 400 A, Ltdb 630 A, Ltdb 800 A, Ltdb 1000 A, Ltdb 1600 A