Description :
Tenders for Corrigendum : Arthroplasty Implants For Dh Dausa - Total Hip Replacement (thr) All Sizesun Cemented: -(metal On Poly) All Should Be Of Same Makeimplant Should Be Usfda Approved Only, The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Lengthoptions, Two Offset Options Minimum And Made Up Of Ti6al4v Material., The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws., Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28mm, 32mm, And 36mm Heads., Femoral Heads Should Be Cocr Metal Head With All Sizes 28mm/32mm/36mm, Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter., Total Hip Replacement (thr) All Sizesun Cemented: -(ceramic On Poly)all Should Be Of Same Makeimplant Should Be Usfda Approved Only, The Femoral Stem Should Have Morphometric Wedge Geometry And Ha Coating/ Porous Coating. Coating Of Minimum 50-micron Thick, Proximal Body Should Be Circumferentially Plasma Sprayed ( Optional ) , Incremental Neck Length Options, Two Offset Options Minimum And Made Up Of Ti6al4v Material., The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws., Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28mm, 32mm, And 36mm Heads., Femoral Heads Should Be Ceramic With All Sizes 28mm/32mm/36mm., Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter., Total Hip Replacement (thr) All Sizescemented: - With Metal On Poly. Note: - All Should Be Of Same Make Except Cementimplant Should Be Usfda Approved Only, Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design., The Cemented Cup Should Have Ultra-high Molecular Weight Polyethylene With Pmma Cement Spacer Easily Identifiable The Cup Position On An X-ray. Cup Should Be Available In The I.d 28 /32 / 36 Mm With Od 46 60 Mm With Two Packets Of Bone Cement., Femoral Heads Should Be Cocr Metal Head With All Sizes 28mm/32mm/36mm, Total Hip Replacement (thr) All Sizeshybrid ( Metal On Poly ) Note: - All Should Be Of Same Make Except Cementimplant Should Be Usfda Approved Onlynote:- All Should Be Of Same Make Except Cement, The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabular Shell Should Feature Two Independent Locking Mechanisms For Polyethylene Liners And Ceramic Liners ( Optional). The Acetabular Shell Should Have Minimum 3 Hole Options.. The Acetabular Shell Sizes Should Come In Sizes From 44 To 62 Mm With Required Cancellous Bone Screws., Insert Should Be Highly Cross Linked Polyethylene. The Polyethylene Has 10-degree Or More Posterior Superior Lip. The Polyethylene Is Compatible To Accommodate 28mm, 32mm, And 36mm Heads., Cemented Femoral Stem Should Highly Polished, Double Tapered With Collarless Design With Required Bone Cement., Femoral Heads Should Be Cocr Metal With All Sizes 28mm/32mm/36mm, Cancellous Bone Screws Of 6.5 Mm In Length And 20 To 60 Mm In Diameter., Total Hip Replacement (thr) All Sizes -hybrid: (ceramic On Poly) Note: - All Should Be Of Same Make Except Cementimplant Should Be Usfda Approved Only, The Acetabular Shell Should Ha Coated/ Porous Coating. The Acetabu