Web Analytics Made Easy - StatCounter

Tender for Supply Of Low Maintenance Lead Acid Stationary Secondary Cell 2v 80 Ah. With Hard Rubb Er Container With Accessories Inter Cell Connectors , Nuts Bolts And Washers, Micro Poro Us Ceramic Vent Plug In Dry And Uncharged Condition,conforming To Rdso . Specification Ir S-s-88/2004 With Latest Amendments. A Wall Mounting Type "tool Board" Of Suitable Material And Prote Cted Against Acid Fumes Shall Be Supplied Along With Set Of 12 Nos. Each Battery. The Tool Board Shall Com Prise: I) One Syringe For Adding Or Taking Out Electrolyte From The Cells. Ii) One Syringe Type Hydrometer Of Requisite Range For Measuring The Specific Gravity Of Electrolyte In The Cells .this Shall Be Provided With A Gr Aduated Scale, On Division Of Which Representing At The Most 0.005 Unit Of Specific Gravity With Accuracy Of Calibration Not Less Than 0.005 Units Of Specific Gravity. Iii) One Cell- Testing %u2013voltmeter, 0 %u2013 3 V Of Accuracy, Class 0.5 In Accordance With Is:1248-1968.the Resistance Of The Voltmeter Shall Be 1000 Oh Ms/volt. Iv) One Thermometer With An Appropriate Scale For Measuring Temperature Of Electrolyte .one Div Ision Of Graduated Scale Of The Thermometer Shall Represent At The Most 1deg.c, The Accuracy Of Calibration Being Not Less Than 0.5deg.c. [ Warranty Period: 48 Months After The Date Of Delivery ] in Bhubaneswar - Odisha

Tender Details
Reference # :
40699342
Description :
Tenders for Supply Of Low Maintenance Lead Acid Stationary Secondary Cell 2v 80 Ah. With Hard Rubb Er Container With Accessories Inter Cell Connectors , Nuts Bolts And Washers, Micro Poro Us Ceramic Vent Plug In Dry And Uncharged Condition,conforming To Rdso . Specification Ir S-s-88/2004 With Latest Amendments. A Wall Mounting Type "tool Board" Of Suitable Material And Prote Cted Against Acid Fumes Shall Be Supplied Along With Set Of 12 Nos. Each Battery. The Tool Board Shall Com Prise: I) One Syringe For Adding Or Taking Out Electrolyte From The Cells. Ii) One Syringe Type Hydrometer Of Requisite Range For Measuring The Specific Gravity Of Electrolyte In The Cells .this Shall Be Provided With A Gr Aduated Scale, On Division Of Which Representing At The Most 0.005 Unit Of Specific Gravity With Accuracy Of Calibration Not Less Than 0.005 Units Of Specific Gravity. Iii) One Cell- Testing %u2013voltmeter, 0 %u2013 3 V Of Accuracy, Class 0.5 In Accordance With Is:1248-1968.the Resistance Of The Voltmeter Shall Be 1000 Oh Ms/volt. Iv) One Thermometer With An Appropriate Scale For Measuring Temperature Of Electrolyte .one Div Ision Of Graduated Scale Of The Thermometer Shall Represent At The Most 1deg.c, The Accuracy Of Calibration Being Not Less Than 0.5deg.c. [ Warranty Period: 48 Months After The Date Of Delivery ]
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
NA
Doc. Cost :
NA
Important Dates
Due date :
07 Jul, 2025
Open date :
07 Jul, 2025
Publish date :
12 Jun, 2025
Location
Location :
Bhubaneswar - Odisha ( IN )
Connect us via What's Up