Description :
Tenders for Procurement Of Electrical Material For Day To Day Repair And Maintenance At Various Ctcs (community Toilet Complexes) And Pts (public Toilets) Under South Zone (for Swachhta Survekshan - 2025) - Rewiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.mm. Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existing Surface/ Recessed Steel/pvc Conduit Including Dismantling As Required.group C, Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm, Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3x1.5 Sq. Mm, Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3x2.5 Sq. Mm, Supplying And Fixing Following Piano Type Switch/ Socket On Theexisting Switch Box/ Cover Including Connections Etc. As Required. (a)5/6 Amps Switch, Supplying And Fixing Following Piano Type Switch/ Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required. (a) 3 Pin 5/6 A Socket Outlet, Supplying And Fixing Metal Box Of 180mm X 100mm X 60mm Deep (nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 6 Pin 5/6 & 15/16 A Socket Outlet And 15/16 A Piano Type Switch, Connections, Painting Etc. As Required., Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage Connection Testing, Commissioning Etc. As Required.upto 450 Mm Sweep, Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, "c" Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.single Pole, Supplying And Fixing Following Rating ,double Pole,240 Volt,isolator In The Existing Mcb Db Complete With Connections,testing And Commissioning Etc. As Required.(b) 63 Amps, Supply Of 250 Mm (10 Inch) Sweep 1250 Rpm Exhaust Fan Fresh Air Type Complete With Shutter Blades Etc. As Required., Supplying, Installation, Testing & Commissioning Of Led Surface Mountedbatten Light Of Following Body Material And Construction As Per Is : 10322with Driver (replaceable) As Per The Requirement With Driver Efficiency>85% ,operating Voltage Ac 140-270 Volt, Freq 50/60 Hz, Operating Temprange -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv Withshort & Open Circuit Protection ,thd 10% , P. F. 0.95, Ip20, Cri >80,flicker Free, (flicker Should Be Below 5 %), Life Time (led,driver & Electricalcircuitary), Of Minimum 50000 Burning Hours With , 70% Of Initiallumen Maintained Till Life Ends, Cct 3000 K / 4000 K / 5700 K/6000 K/6500 K (as Per Ansi Bin), Sdcm(standard Deviation Colormatching) 3, Maximum Power Consumption Should Not More Than Thespecified Rating And Fixture Shall Be Of Relevant Bis Standard And Trademark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/embossing/ Screen Printing On Housing. Complete In All Respect I/cconnections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductorsingle Core Cable And Earthing Etc. As Required With Minimum 5 Year Oemwarranty. System Lumen Efficacy 105 120 Lm/watt Output . Lm79 & Lm80test Report From Nabl Lab For All Testing Required For Led Fixtures Asper Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved Byengineer-in-charge As Per Requirement. (thermal Management: Heat Sinkof Aluminum Housing Such That Led Junction Temperature Shall Not Riseabove 90 C). 18- 22 Watt, Supply,installation,testing And Commissioning Of Single /three Phase Monoblock Pumpset Complete With All Accessories Workable On 240/