Description :
Tenders for Engineering Defect Rectification - Defect Rectification Of Various Engineering Defects As Per Rfp, E-678: Aft Ac Sea Water Pump Not Developing Sufficient Pressure And Excessive Vibration Observed. Suspect Pump Impeller, Shaft And Bearing Worn Out. Defect To Be Rectified And Pump To Be Proved For Satisfactory Operation. In Way Job Includes Removal And Re-fitment Of Pump In Position., E-763: Abnormal Noise/ Vibration Observed From Stbd Sea Water Pump Of Ref Plant View Pump Shaft And Bearing Worn Out. Defect To Be Rectified And Proved For Satisfactory Operation. In Way Job Includes Removal And Fitment Of Pump., E-764:lub Oil Leakage Observed From Port Gearbox Built On Sea Water Pump Tell Tale Hole. Suspect Oil Seal Worn Out. Defect To Be Rectified And Pump To Be Proved For Satisfactory Operation. In Way Job Includes Removal And Re-fitment Of Pump In Position.