Web Analytics Made Easy - StatCounter

Tender for Supply Of Various Lab Equipments Items For Govt. Pg College Guna District Guna (m.p.) - Supply Of Various Lab Equipments Items For Govt. P G College Guna District Guna (m.p.), Waterand Soil Testing Analysis Kit (digital) : Range Ph 0 To 14.00 Resolution Ph 0.01 Accuracy Ph 0.01 1 Digit Temp. Comp. 0 To 100 Deg. C., Water Bath (06holes) : 6 Hole8 Ltrs., Waterbath(12holes) :12 Hole 20 Ltrs., Water Distillation Apparatus(single Distillation Unit 2 Litre/hour) : Single Distillation 5 Litres, Analytical Balance : Least Cosunt 0.0002g, Analytical Weight Box : 1-100g, Fractional Weight Box : 1-500mg, Physical Balance : 250gm Accuracy 0.1g, Digital Balance : Least Count 1mg, Single Pandigital Balance : 0.1mg 200g, Digital Photoelectric Colorimeter : 8 Filter,1 Ml, Digital Potentiometer : With Hot Plate And Electrodes, Digital Conductometer : With Cell 1cc And 0.1cc, D.o. Meter : Polarographic Do Range: Typically 0 To 90 Mg/l (milligrams Per Liter) Or 0 To 600% Saturation.rdo (optical) Do Range: Usually 0 To 50 Mg/l Or 0 To 500% Saturation., Digital Naphelo/turbidity Meter : Digital Turbidity Cum Nephelometer Range:-, 200,1000 Ntu/jtu Resolution:- 0.01 Ntu/jtu Accuracy:- 3% Fs, 1digit Display:- 3 Digit 7-segment Led Light Source:- Ir Led Detector:- Photodiode Sample System:- 60 X 25mm Clear Glass Test Tubes Power:- 230 V 10% Ac, 50 Hz Accessories:- Test Tube Set Of 2, Operation Manual, Dust Cover, Polarimeter Half Shade : The Specific Rotation ( ) Is A Physical Property Defined As The Optical Rotation At A Path Length Of 1 Dm, A Concentration Of 10 G/l, A Temperature (usually 20 C), And A Light Wavelength (usually Sodium D Line At 589.3 Nm), Melting Point Apparatus :melting-point Measurement Range: Room Temperature - 400 C Setting Rate Of The Starting Temp. : 50 C~400 C 5 Min; 400 C~50 C 7 Min Minimum Digital Display: 0.1 C Size Of The Capillary: 1.4mm (outside Diameter) 1.0mm (inside Diameter), 90mm Equipped With Color Camera And Color Monitor To Observe Melting Point With Ease Validation Program For Standard Samples 8 Operator Names Can Be Storedgraphic Lcd Display To Display All Test Parameters & Test Instructions, Digital Melting Point Apparatus :melting Point Measurement Range : Ambient To 300 Deg C Starting Melting Point Temperature : Settable From 50 To 300 Deg C Heating Time : 3 Minutes (up To 300deg C) Cooling Time : 5 Minutes (from 300 Deg C) Accuracy : +/ 0.5 Deg Up To 200 +/ 0.8 Deg From 200 To 300 Temperature Display Resolution : 0.1 Deg C Rate Of Heating (deg C Per Minute), Abbe Refractometer : Safety Bs En 60950-1:11/2006 Emc En 55024 : 10/2003 En 55020 : 11/2005, Tlc Kit : Outstanding Standardization And Quality Control Exceptional Adherence, Hardness And Surface Homogeneity. Analyzing Samples With High Matrix- Load Without Sample Preparation. Multiple Samples Analyzed In Parallel.highly Cost-efficient, Fast And Economical, Centrifuge : 6000rpm, Corkboring Machine :adjustable Guide That Permits Holes To Be Bored In Any Part Of A Stopper, The Knurled Chuck - 9/16" (14mm) Shank Of The Eight, Plated-steel Borers Included With The Unit. The Steel Borers Range From 3/16" To 5/8" (4.8mm To 15.9mm) In 1/16" (1.6mm) Increments,, Distillation Apparatus : Single Distillation 5 Litres, Oven Hot Air : 14" 14" 14 , Voltage Stabilizer : 2kv, Vertex Shaker : 6 Tube Capacity, Mixer Small : Moter Capacity 900 Watt, Water Bath(cu) : 4 , Heating Mantle With Energy Regulator : 500 W,2litre, Single Crucible Heater : Helical Wire Coil Moldatherm Insulation Platinel Ii Thermocouple With 10tm Compensated Lead Wire And Polarized Plug Ceramic Fiber Hearthplate Programmable Heat-up To Setpoint Temperature Indicates Setpoint And Process Temperatures Temperature: 1200 C (2192 F) Maximum Crucible Sizes: 5 (top Vestibule Id) X 8 (heated Depth), Water Bath Rectangularsingle Walled : 6 Hole 8 Ltrs., Water Bath Rectangular :2 Hole, Kjeldahl Distillation Unit : Unit Of 3 Tests, Microwave Oven : 30 Ltr Convection Compatible, Soleextractionunit Apparat in Guna - Madhya Pradesh

Tender Details
Reference # :
41856221
Description :
Tenders for Supply Of Various Lab Equipments Items For Govt. Pg College Guna District Guna (m.p.) - Supply Of Various Lab Equipments Items For Govt. P G College Guna District Guna (m.p.), Waterand Soil Testing Analysis Kit (digital) : Range Ph 0 To 14.00 Resolution Ph 0.01 Accuracy Ph 0.01 1 Digit Temp. Comp. 0 To 100 Deg. C., Water Bath (06holes) : 6 Hole8 Ltrs., Waterbath(12holes) :12 Hole 20 Ltrs., Water Distillation Apparatus(single Distillation Unit 2 Litre/hour) : Single Distillation 5 Litres, Analytical Balance : Least Cosunt 0.0002g, Analytical Weight Box : 1-100g, Fractional Weight Box : 1-500mg, Physical Balance : 250gm Accuracy 0.1g, Digital Balance : Least Count 1mg, Single Pandigital Balance : 0.1mg 200g, Digital Photoelectric Colorimeter : 8 Filter,1 Ml, Digital Potentiometer : With Hot Plate And Electrodes, Digital Conductometer : With Cell 1cc And 0.1cc, D.o. Meter : Polarographic Do Range: Typically 0 To 90 Mg/l (milligrams Per Liter) Or 0 To 600% Saturation.rdo (optical) Do Range: Usually 0 To 50 Mg/l Or 0 To 500% Saturation., Digital Naphelo/turbidity Meter : Digital Turbidity Cum Nephelometer Range:-, 200,1000 Ntu/jtu Resolution:- 0.01 Ntu/jtu Accuracy:- 3% Fs, 1digit Display:- 3 Digit 7-segment Led Light Source:- Ir Led Detector:- Photodiode Sample System:- 60 X 25mm Clear Glass Test Tubes Power:- 230 V 10% Ac, 50 Hz Accessories:- Test Tube Set Of 2, Operation Manual, Dust Cover, Polarimeter Half Shade : The Specific Rotation ( ) Is A Physical Property Defined As The Optical Rotation At A Path Length Of 1 Dm, A Concentration Of 10 G/l, A Temperature (usually 20 C), And A Light Wavelength (usually Sodium D Line At 589.3 Nm), Melting Point Apparatus :melting-point Measurement Range: Room Temperature - 400 C Setting Rate Of The Starting Temp. : 50 C~400 C 5 Min; 400 C~50 C 7 Min Minimum Digital Display: 0.1 C Size Of The Capillary: 1.4mm (outside Diameter) 1.0mm (inside Diameter), 90mm Equipped With Color Camera And Color Monitor To Observe Melting Point With Ease Validation Program For Standard Samples 8 Operator Names Can Be Storedgraphic Lcd Display To Display All Test Parameters & Test Instructions, Digital Melting Point Apparatus :melting Point Measurement Range : Ambient To 300 Deg C Starting Melting Point Temperature : Settable From 50 To 300 Deg C Heating Time : 3 Minutes (up To 300deg C) Cooling Time : 5 Minutes (from 300 Deg C) Accuracy : +/ 0.5 Deg Up To 200 +/ 0.8 Deg From 200 To 300 Temperature Display Resolution : 0.1 Deg C Rate Of Heating (deg C Per Minute), Abbe Refractometer : Safety Bs En 60950-1:11/2006 Emc En 55024 : 10/2003 En 55020 : 11/2005, Tlc Kit : Outstanding Standardization And Quality Control Exceptional Adherence, Hardness And Surface Homogeneity. Analyzing Samples With High Matrix- Load Without Sample Preparation. Multiple Samples Analyzed In Parallel.highly Cost-efficient, Fast And Economical, Centrifuge : 6000rpm, Corkboring Machine :adjustable Guide That Permits Holes To Be Bored In Any Part Of A Stopper, The Knurled Chuck - 9/16" (14mm) Shank Of The Eight, Plated-steel Borers Included With The Unit. The Steel Borers Range From 3/16" To 5/8" (4.8mm To 15.9mm) In 1/16" (1.6mm) Increments,, Distillation Apparatus : Single Distillation 5 Litres, Oven Hot Air : 14" 14" 14 , Voltage Stabilizer : 2kv, Vertex Shaker : 6 Tube Capacity, Mixer Small : Moter Capacity 900 Watt, Water Bath(cu) : 4 , Heating Mantle With Energy Regulator : 500 W,2litre, Single Crucible Heater : Helical Wire Coil Moldatherm Insulation Platinel Ii Thermocouple With 10tm Compensated Lead Wire And Polarized Plug Ceramic Fiber Hearthplate Programmable Heat-up To Setpoint Temperature Indicates Setpoint And Process Temperatures Temperature: 1200 C (2192 F) Maximum Crucible Sizes: 5 (top Vestibule Id) X 8 (heated Depth), Water Bath Rectangularsingle Walled : 6 Hole 8 Ltrs., Water Bath Rectangular :2 Hole, Kjeldahl Distillation Unit : Unit Of 3 Tests, Microwave Oven : 30 Ltr Convection Compatible, Soleextractionunit Apparat
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
26,310
Doc. Cost :
5,000
Important Dates
Due date :
08 Oct, 2025
Open date :
10 Oct, 2025
Publish date :
16 Sep, 2025
Location
Location :
Guna - Madhya Pradesh ( IN )
Connect us via What's Up