Description :
Tenders for Corrigendum : Supply Of C73340415174 Supply Of High Static Pressure Ductable Ac Unit Capacity 8point5 Tr Having One Indoor And One Out Door Unit Consisting Of Scroll Compressor Refer Annexure Iii , 100000000001 Supply Of Suitable Size Refrigerant Grade Copper Piping Between Indoor And Outdoor Units Of Ductable Split Ac Units 8point5 Tr Refer Annexure Iii , 100000000002 Providing Cpvc Sdr11 Pipes 32 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation Refer Annexure Iii , 100000000003 Providing Of Cpvc Sdr11 Pipes 25 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation Refer Annexure Iii , 100000000004 Supply Of Site Fabricated Gi Sheet Metal Ducts Of 22 Guage Birmingham Gauge 0point8 Mm And Zinc Coating Not Less Than Refer Annexure Iii , 100000000005 Supply Of Thermal Insulation For Supply Air Ducts With 19 Mm Class O Thick Self Adhesive Closed Cell Elastomeric Refer Annexure Iii , 100000000006 Supply Of Acoustic Insulation For Ducting With Open Cell Nitrile Rubber Insulation Or Open Cell Physically Crosslinked Polyolefin Foam Refer Annexure Iii , 100000000007 Supply Of Volume Control Dampers Vcd For Ducts Made Of Gi Sheet Of Thickness Not Less Than 18 G Refer Annexure Iii , 100000000008 Supplying Of Xlpe Insulated, Pvc Sheathed, Armoured, Copper Conductor 1point1 Kv Grade Lt Cable Of Size 4 Core - 6 Sqmm Refer Annexure Iii , 100000000009 Supply Of Xlpe Insulated, Pvc Sheathe, Copper Conductor, , 1point1 Kv Grade Lt Cable Of Size 4 Core - 2point5 Sqmm Refer Annexure Iii , 100000000010 Supply Of 300 Mm Width X 50 Mm Depth X 1point6 Mm Thickness Perforated Hot Dipped Galvanised Iron Cable Tray With Cover Refer Annexure Iii , 100000000011 Supply Of 150 Mm Width X 50 Mm Depth X 1point6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray Refer Annexure Iii , 100000000012 Installation Testing And Commissioning Of High Static Pressure Ductable Ac Unit ) /bid Number : Gem/2025/b/6778840 * /dated: 13-10-2025 & & / Bid Document 1 / 20 & & ' ' /item Category Capacity 8point5 Tr Refer Annexure Iv , 100000000013 Erection Testing And Commissioning Of Suitable Size Refrigerant Grade Copper Piping Between Indoor And Outdoor Units Of Ductable Split Ac Refer Annexure Iv , 100000000014 Laying Of Cpvc Sdr11 Pipes 32 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation Refer Annexure Iv , 100000000015 Laying Of Cpvc Sdr11 Pipes 25 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation Refer Annexure Iv , 100000000016 Fabrication Installation Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 22 Guage Refer Annexure Iv , 100000000017 Fixing Thermal Insulation For Supply Air Ducts With 19 Mm Refer Annexure Iv , 100000000018 Fixing Acoustic Insulation For Ducting With Open Cell Nitrile Rubber Insulation Or Open Cell Physically Crosslinked Polyolefin Foam Refer Annexure Iv , 100000000019 Erection Testing And Commissioning Of Volume Control Dampers Vcd For Ducts Made Of Gi Sheet Refer Annexure Iv , 100000000020 Laying Of Xlpe Insulated,pvc Sheathed, Armoured,copper Conductor,1point1 Kv Grade Lt Cable Of Size 4 Core - 6 Sqmm Refer Annexure Iv , 100000000021 Laying Of Xlpe Insulated, Pvc Sheathe, Copper Conductor 1point1 Kv Grade Lt Cable Of Size 4 Core - 2point5 Sqmm Refer Annexure Iv , 100000000022 Installation Of 300 Mm Width X 50 Mm Depth X 1point6 Mm Thickness Perforated Hot Dipped Galvanised Iron Cable Tray With Cover Refer Annexure Iv , 100000000023 Installation Of 150 Mm Width X 50 Mm Depth X 1point6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray Refer Annexure Iv , 100000000024 Dismantling And Shifting Of Existing Ductable Indoor And Outdoor 23 X8point5 Tr Outdoors Are Installed At Roof Tops Of First To Third Floor Refer Annexure Iv , 100000000025 Dismantling And Installation Of Existing False Ceiling Approx 800 Sqfeet For Installation Of Ductable Split Ac Above False Ceiling With All Fitting Same As Before Refer Annexure Iv