Description :
Tenders for Corrigendum : Supply Installation And Commissioning Of Central Ac To Nirmithi Kendra, Raichur - Lifting Shifting, Loading Unloading And Installation ,transportation Charges, Lifting Shifting, Loading Unloading And Installation ,transportation Charges, Supply & Installation Of Propeller Fan. 100 Cfm, Supply & Installation Of Propeller Fan. 100 Cfm, Supply & Installation Of Mixed Flow Inline Fan. 500 Cfm 15mm Static, Supply & Installation Of Mixed Flow Inline Fan. 500 Cfm 15mm Static, Supply & Installation Of Louverwith Bird Mesh, Supply & Installation Of Louverwith Bird Mesh, Supply & Installation Of Pvc Pipes. Dia -110mm, Supply & Installation Of Pvc Pipes. Dia -110mm, Supply & Installation Of Pvc Pipes. Dia -160mm, Supply & Installation Of Pvc Pipes. Dia -160mm, Supply & Installation Of Dise Valve. Dia -100mm, Supply & Installation Of Dise Valve. Dia -100mm, Supply & Installation Of Uninsulated Flexible Duct. Dia -150mm, Supply & Installation Of Uninsulated Flexible Duct. Dia -150mm, Supply Installation Testing And Commissioning Of Al.powder Coated Collar Damper., Supply Installation Testing And Commissioning Of Al.powder Coated Collar Damper., Supply, Installation Testing And Commissioning Of Aluminum Extruded Powder Coated Grill With Blade Deflection Of 0 - 30 Deg As Required., Supply, Installation Testing And Commissioning Of Aluminum Extruded Powder Coated Grill With Blade Deflection Of 0 - 30 Deg As Required., Supply, Installation, Testing And Balancing Of Gss Volume Control Dampers With Operating Handle For Supply Air Duct Branches. The Volume Control Damper Shall Be Of Low Leakage Type With The Outer Shell Constructed Of 1.6mm Thick Galvanized Steel Frame And The Blade/leaf With 1.6mm Thick Gss. And With Necessary Flanges For Connection Etc., As Per Specification., Supply, Installation, Testing And Balancing Of Gss Volume Control Dampers With Operating Handle For Supply Air Duct Branches. The Volume Control Damper Shall Be Of Low Leakage Type With The Outer Shell Constructed Of 1.6mm Thick Galvanized Steel Frame And The Blade/leaf With 1.6mm Thick Gss. And With Necessary Flanges For Connection Etc., As Per Specification., Supply ,installation And Testing Of Class O 9mm Thick, Elastomeric Nitrile Rubber Or Physically Cross Linked Polyolefin Foam Thermal Insulation., Supply ,installation And Testing Of Class O 9mm Thick, Elastomeric Nitrile Rubber Or Physically Cross Linked Polyolefin Foam Thermal Insulation., Supply ,installation And Testing Of Accoustic Lining With Physically Crosslinked Open Cell Polyolefin Foam Insulation For Supply And Return Duct Of Density 30kg/m3 Of Fire Retardant Grades With Thickness Of 10 Mm Nrc Of Material Should Be Atleast 0.35 Tested As Per Iso 354-2000 And Calculated In Accordance With Astm C423-90a., Supply ,installation And Testing Of Accoustic Lining With Physically Crosslinked Open Cell Polyolefin Foam Insulation For Supply And Return Duct Of Density 30kg/m3 Of Fire Retardant Grades With Thickness Of 10 Mm Nrc Of Material Should Be Atleast 0.35 Tested As Per Iso 354-2000 And Calculated In Accordance With Astm C423-90a., Supply, Fabrication, Installation Fire Resistance Flexible Double Canvas Sleeve For Ductable Split And Airwasher Fan ., Supply, Fabrication, Installation Fire Resistance Flexible Double Canvas Sleeve For Ductable Split And Airwasher Fan ., Supply, Fabrication, Installation And Testing Of Sheet Metal Ducts (factory Fabricated Ducts) In Accordance With The Approved Shop Drawings Complete With All Accessories Like Vanes, Flanges, Suspension Rods, Anchor Bolts, Gi Bolts & Nuts, Canvas Connections, Duct Dampers & Splitter Dampers Etc.,and As Required By The Specifications. All Size Duct Should Be With Tdf Joints. No C & Ss Clip Joints Should Be Used 24g, Supply, Fabrication, Installation And Testing Of Sheet Metal Ducts (factory Fabricated Ducts) In Accordance With The Approved Shop Drawings Complete With Al