Web Analytics Made Easy - StatCounter

Tender for Tender For Supply Of Laboratory Equipments Andinstruments - Machinery & Equipment, Hplc Module Pump(quaternary Gradient) High Precision Dual Plunger Design. System Designed To Work In Micro , Semi-micro Analytical To Semi Prep Scale High Speed Double Micro Plunger In Parallel Pump With Automatic Pulsation Correction Mechanism Achieving Pulse Free Solvent Delivery Forced Check Valve Designed For Excellent Solvent Delivery Control Flow Raterange:0.0001ml To 10.0ml/min Each Pump Flow Rate Resolution Of 3nl/step Increment Built In Self Diagnostic, Auto Purge Function Flow Precision Is Less Than 0.06% Rsd Flow Rate Accuracy: 1% Concentration Accuracy 0.5%washing Kitgradient Mixer,reservoir Trayquaternary Gradient Unitdgu-20a5r Bkl Degassing Unitmanual Injector: Rheodyne Injector With 20 Ul Loop & Mounting Plate 25ul Hamilton Syringepda Detectorwavelength 190 800 Nm, Channel 512, Drift Smaller Than 0.5x10-3 Au/hour, Noise Smaller Than 0.6x10-5 Au. Wavelength Accuracy Should Be 1 Nm, Linearity: 2.0au Or More. A Deuterium Lamp [d2] And A Tungsten Lamp [w] Should Be Available As Light Source A Conventional Hplc Flow Cell [12 L Volume, 10 Mm Cell Path Length]. Lamp Replacement: Front Access, Lamp Life Time : 2000 Hours (d2 Lamp)controller Alite System Controller, Solvent Bottles With Cap 5/pkt, Chromatographic Software in Panaji - Goa

Tender Details
Reference # :
42847302
Description :
Tenders for Tender For Supply Of Laboratory Equipments Andinstruments - Machinery & Equipment, Hplc Module Pump(quaternary Gradient) High Precision Dual Plunger Design. System Designed To Work In Micro , Semi-micro Analytical To Semi Prep Scale High Speed Double Micro Plunger In Parallel Pump With Automatic Pulsation Correction Mechanism Achieving Pulse Free Solvent Delivery Forced Check Valve Designed For Excellent Solvent Delivery Control Flow Raterange:0.0001ml To 10.0ml/min Each Pump Flow Rate Resolution Of 3nl/step Increment Built In Self Diagnostic, Auto Purge Function Flow Precision Is Less Than 0.06% Rsd Flow Rate Accuracy: 1% Concentration Accuracy 0.5%washing Kitgradient Mixer,reservoir Trayquaternary Gradient Unitdgu-20a5r Bkl Degassing Unitmanual Injector: Rheodyne Injector With 20 Ul Loop & Mounting Plate 25ul Hamilton Syringepda Detectorwavelength 190 800 Nm, Channel 512, Drift Smaller Than 0.5x10-3 Au/hour, Noise Smaller Than 0.6x10-5 Au. Wavelength Accuracy Should Be 1 Nm, Linearity: 2.0au Or More. A Deuterium Lamp [d2] And A Tungsten Lamp [w] Should Be Available As Light Source A Conventional Hplc Flow Cell [12 L Volume, 10 Mm Cell Path Length]. Lamp Replacement: Front Access, Lamp Life Time : 2000 Hours (d2 Lamp)controller Alite System Controller, Solvent Bottles With Cap 5/pkt, Chromatographic Software
Ownership :
Sector :
Tender Values
Value :
NA
EMD :
120,000
Doc. Cost :
1,500
Important Dates
Due date :
08 Dec, 2025
Open date :
09 Dec, 2025
Publish date :
20 Nov, 2025
Location
Location :
Panaji - Goa ( IN )
Connect us via What's Up