Web Analytics Made Easy - StatCounter

Tender for Corrigendum : Tender For Supply Of Various Implants And Instruments - (a) Plate Group, D.h.s. Plate Long/short Barrel (38/25 Mm)with Round, D. C., Combi Holes 1250, 1300, 1350, 1400 Angle;2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes, D.h.s Screw 22mm /16mm Threading With Compression Screw (top-bolt). (36 Mm)50 To 115 Mm, In 5mm Increments, Pediatric D.h.s. Set, D.c.s Plate (950) With Round, D. C., Combi Holes4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 Holes, Angle Blade Plate (950) With Round, D. C., Combi Holesblade Size 50, 55, 60, 65, 70 & 75 Mm4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 Holes, Trochanteric Stabilisation Plate To Be Used With Dhs, Distal Femur Locking Compression Plate (right & Left)anatomical Pre-shaped & Contoured With Self-tapping Locking Head Screws; With Round Locking Holes For Metaphyseal Portion Of Plate & Combiholes For Shaft Of Plate., Medial & Lateral Proximal Tibial Buttress Plate (t- & L- Shape)- As Per Ao Specifications.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Proximal Medial & Lateral Tibial Plate 3.5 Mm(right & Left)anatomically Pre Shaped And Low Profile.two Different Plate Design For Left And Right Side With Indication On Side Of Plate.plate Should Have 2 Mm Holes For Proximal Fixation With K-wire And Sutures For Meniscal Repair.holes Should Accept 3.5 Mm Locking Head Or 3.5 Mm Standard Cortical Screws From 4 To 20 Holes With Increment Of 2 Holes., Proximal Medial/ Lateral Tibial Locking Plate For 4.5 Mm Screwsanatomically Pre Shaped And Low Profile Design, Two Different Plate Design For Left And Right With Indication On Plate.round Metaphyseal Locking Holes And Combi Holes In Shaft Portion For Locking And Standard Screws.different Angulation In Proximal Part Of The Plate To Avoid Primary And Secondary Loss Of Reductionshould Be Compatible For Less Invasive Techniqueholes Should Accept 5 Mm Locking Head Or 6.5 Mm Standard Cancellousl Screws From 5 To 13 Holes, Hockey Plate For Tibia (right & Left)5, 7, 9, 11, 13, 15, 17 Holes, Contoured Medial/ Antero-lateral Plate For Lower End Tibia4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Distal Medial Tibial Locking Plates 2.7/ 3.5 Mm1. Anatomically Pre-shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate, Compatible With Less Invasive Fixation.2. Rounded Edges Screw Heads Should Be Received Into Distal Section Of Plate To Allow Multiple Locking Head Screw Placement Of 2.7/ 3.5 Mm To Provide Adequate Fixation Of Metaphyseal Portion Of Tibia, And Size 4 To 14 Holes With Increment Of 2 Holes., Anterolateral Distal Tibial Locking Plate 3.5 Mm1. Anatomically Pre Shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate. Plate Should Have Head Holes To Accept 3.5 Mm Locking Head Or Standard Cortical Or 4 Mm Standard Cancellous Screw.2. Head Should Be Received Into The Plate.3. Size From 5 To 21 Holes With Increment Of 2 Holes, Cobra Head Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Cobra Head Locking Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Hook Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Hook Locking Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Proximal Humerus Locking Plate (philos Plate)anatomically Pre-countoured Platesshould Have Precisely Fitting Sleeves For Precision Placement Of Screwsshould Accept 3.5 Mm Locking Head Screws.the Screws Provided Should Be Available From 26 To 60 Mm Length.the Head Of The Plate Should Have Holes For Securing Tuberosities To The Plate With Sutures.should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation3, 4, 5, 6, 7, 8, 9, 10, 12 Holes, Contoured Locking Plate For Distal End Humerus.(prices To Be Quoted Separately For The Following 2 Items)(a)anatomically Pre-countoured Plates For Distal Medial Humerus For Anatomical Fit With Left & Right Versionshould Have Precisely Fitting Sleeves For Precision Placement Of Screws.should Accept S in Sagar - Madhya Pradesh

Tender Details
Reference # :
43093132
Description :
Tenders for Corrigendum : Tender For Supply Of Various Implants And Instruments - (a) Plate Group, D.h.s. Plate Long/short Barrel (38/25 Mm)with Round, D. C., Combi Holes 1250, 1300, 1350, 1400 Angle;2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes, D.h.s Screw 22mm /16mm Threading With Compression Screw (top-bolt). (36 Mm)50 To 115 Mm, In 5mm Increments, Pediatric D.h.s. Set, D.c.s Plate (950) With Round, D. C., Combi Holes4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 Holes, Angle Blade Plate (950) With Round, D. C., Combi Holesblade Size 50, 55, 60, 65, 70 & 75 Mm4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 Holes, Trochanteric Stabilisation Plate To Be Used With Dhs, Distal Femur Locking Compression Plate (right & Left)anatomical Pre-shaped & Contoured With Self-tapping Locking Head Screws; With Round Locking Holes For Metaphyseal Portion Of Plate & Combiholes For Shaft Of Plate., Medial & Lateral Proximal Tibial Buttress Plate (t- & L- Shape)- As Per Ao Specifications.3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Proximal Medial & Lateral Tibial Plate 3.5 Mm(right & Left)anatomically Pre Shaped And Low Profile.two Different Plate Design For Left And Right Side With Indication On Side Of Plate.plate Should Have 2 Mm Holes For Proximal Fixation With K-wire And Sutures For Meniscal Repair.holes Should Accept 3.5 Mm Locking Head Or 3.5 Mm Standard Cortical Screws From 4 To 20 Holes With Increment Of 2 Holes., Proximal Medial/ Lateral Tibial Locking Plate For 4.5 Mm Screwsanatomically Pre Shaped And Low Profile Design, Two Different Plate Design For Left And Right With Indication On Plate.round Metaphyseal Locking Holes And Combi Holes In Shaft Portion For Locking And Standard Screws.different Angulation In Proximal Part Of The Plate To Avoid Primary And Secondary Loss Of Reductionshould Be Compatible For Less Invasive Techniqueholes Should Accept 5 Mm Locking Head Or 6.5 Mm Standard Cancellousl Screws From 5 To 13 Holes, Hockey Plate For Tibia (right & Left)5, 7, 9, 11, 13, 15, 17 Holes, Contoured Medial/ Antero-lateral Plate For Lower End Tibia4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Distal Medial Tibial Locking Plates 2.7/ 3.5 Mm1. Anatomically Pre-shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate, Compatible With Less Invasive Fixation.2. Rounded Edges Screw Heads Should Be Received Into Distal Section Of Plate To Allow Multiple Locking Head Screw Placement Of 2.7/ 3.5 Mm To Provide Adequate Fixation Of Metaphyseal Portion Of Tibia, And Size 4 To 14 Holes With Increment Of 2 Holes., Anterolateral Distal Tibial Locking Plate 3.5 Mm1. Anatomically Pre Shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate. Plate Should Have Head Holes To Accept 3.5 Mm Locking Head Or Standard Cortical Or 4 Mm Standard Cancellous Screw.2. Head Should Be Received Into The Plate.3. Size From 5 To 21 Holes With Increment Of 2 Holes, Cobra Head Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Cobra Head Locking Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Hook Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Hook Locking Plate3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes, Proximal Humerus Locking Plate (philos Plate)anatomically Pre-countoured Platesshould Have Precisely Fitting Sleeves For Precision Placement Of Screwsshould Accept 3.5 Mm Locking Head Screws.the Screws Provided Should Be Available From 26 To 60 Mm Length.the Head Of The Plate Should Have Holes For Securing Tuberosities To The Plate With Sutures.should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation3, 4, 5, 6, 7, 8, 9, 10, 12 Holes, Contoured Locking Plate For Distal End Humerus.(prices To Be Quoted Separately For The Following 2 Items)(a)anatomically Pre-countoured Plates For Distal Medial Humerus For Anatomical Fit With Left & Right Versionshould Have Precisely Fitting Sleeves For Precision Placement Of Screws.should Accept S
Ownership :
Sector :
Tender Values
Value :
1,500,000
EMD :
100,000
Doc. Cost :
2,000
Important Dates
Due date :
02 Jan, 2026
Open date :
05 Jan, 2026
Publish date :
08 Dec, 2025
Location
Location :
Sagar - Madhya Pradesh ( IN )
Connect us via What's Up