Description :
Tenders for Supply Of Wiring , Ups , Light , Fire Alarm , Hvac Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.mm Frls/hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.mm Frls/hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C, Wiring For Group Controlled (looped) Light Point/fan Point/exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls/hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls/hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C, Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire, Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq.mm +1 X 4 Sq.mm Earth Wire, Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire, Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire, Wiring For Circuit/ Submain Wiring Along With ) /bid Number : Gem/2026/b/7105844 * /dated: 13-01-2026 & & / Bid Document 1 / 61 Earth Wire With The Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire, Supplying And Fixing Suitable Size Gi Box Of 1.2 Mm Thickness (min.) With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch, Connections Etc. As Required., Supplying And Fixing Suitable Size Gi Box Of 1.2 Mm Thickness (min.) With Modular Plate And Cover In Front On Surface Or In Recess ,including Providing And Fixing 6 Pin 15 / 16 & 5 / 6 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection, Etc.as Required., Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5star Rated, Ceiling Fan With Brush Less Direct Current (bldc) Motor, Class Of Insulation: B,3 Nos. Blades, Suitable Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9,service Value (cmm/w) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required., Supplying And Fixing Following Way Prewired Triple Pole And Neutral, Sheet Steel For 415 Volts On Surface/recess Complete With Loose Wire Box, Terminal Connector For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Frls Pvc Insulated Multi Strand Copper Conductor Upto Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. (but Without Mcb / Rccb / Isolator) 4 Way (4+12) Double Door, Supplying And Fixing Following Way Prewired Triple Pole And Neutral, Sheet Steel For 415 Volts On Surface/recess Complete With Loose Wire Box, Terminal Con