Web Analytics Made Easy - StatCounter

Tender for Corrigendum : Supplying Installation Testing And Commissioning Of Laundry Equipment In Ashadeep Narela Delhi - Supplying Installation Testing And Commissioning Of Laundry Equipment In Ashadeep Narela Delhi - Sitc Of Front Loading Washing Machine With Loading Capacity Of 30 Kg Dry Weight Per Charge Heavy Duty , Electrically Heater Inner Basket & Outer Drum Stainless Steel, Micro Countroller Base Cyclic Timer For Auto- Reserve, Auto- Timer & Auto Digital Temperature Control, Water- Inlet Valve Drain Valve Complete With Control Panel, & Electric Motor For Wash, Driver Through Pulleys & V- Belts And Control Panel Operator On 3ph, 415 V, 50 Hz, A.c. Supply Operation Cycle 30 To 40 Mintutes Complete Connection Etc As Required, Sitc Of Hydro Extractor Machine Direct- Driver Self- Balance With Automatic Electromangnetic Dc Injection Brake System Having Capaciy Of 30 Kg Per Charge With Auto -timed Top Loading Vibration Less Innner Basket And Outer Drum Stainless Steel Complete With Specially Designed Electric Motor And Control Panel Operator On 415 V,3 Phase , 50 Hz Ac Supply . Operation Cycle 5 To 10 Mintes Complete Connection Etc As Required., Sitc Of Drying Tumbler Machine Front Loading Open Pocket, Electrically Heater With Loading Capacity Of 30 Kg . Per Charge Complete With Micro Controller Base Cyclic Timer For Auto Timed & Auto - Reserver, Auto Digital Temperature Control, Fitted With Control Panel , One Motor Each For Driver And Blower Double Walled Glass Wool Insulated Outer Body Mild Steel With Inner Basket Stainless Steel, Self Lint Screen , V Belt Driver Waster Air Exhaust Etc Operates On 415 V, Phase 50 Hz Ac Supply . Operation Cycle 40 To 60 Mintes Complete Connection Etc As Reqd, Supplying And Drawing Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.a) 3 X 4 Sq. Mm, B) 6 X 4 Sq. Mm, Supplying And Fixing Of Following Capacity, 240/415 Volts, 10ka/15ka C Series Mcbs Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc As Reqd.a) 40a, 10 Ka , Fp Mcb (415v), B) 63a, 10 Ka , Fp Mcb (415v), Supplying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Complete As Required.a) 4x 16 Sqmm, B) 4x 25 Sqmm, Supplying, Installation, Testing & Commissioning Of Led Surface Mounted Batten Light Of Following Body Material And Construction As Per Is : 10322 With Driver (replaceable) As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140- 270 Volt, Frequency 50/60 Hz, Operating Temp Range -5 C To 40 C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10%, P. F. 0.95, Ip20, Cri >80, Flicker Free, (flicker Shouldbe Below 5 %), Life Time (led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000 K / 4000 K / 5700 K /6500 K (as Per Ansi Bin), Sdcm(standard Deviation Colour Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/c External Connections With 1.5 Sq Mm Frls/hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 105 120 Lm/watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-in-charge As Per Requirement. (thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90 C). Powder Coated Die Cast /extruded Aluminium Body (thickness > 1.20 Mm)a) 40 Watt, Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Follow in Delhi - Delhi

Tender Details
Reference # :
43754834
Description :
Tenders for Corrigendum : Supplying Installation Testing And Commissioning Of Laundry Equipment In Ashadeep Narela Delhi - Supplying Installation Testing And Commissioning Of Laundry Equipment In Ashadeep Narela Delhi - Sitc Of Front Loading Washing Machine With Loading Capacity Of 30 Kg Dry Weight Per Charge Heavy Duty , Electrically Heater Inner Basket & Outer Drum Stainless Steel, Micro Countroller Base Cyclic Timer For Auto- Reserve, Auto- Timer & Auto Digital Temperature Control, Water- Inlet Valve Drain Valve Complete With Control Panel, & Electric Motor For Wash, Driver Through Pulleys & V- Belts And Control Panel Operator On 3ph, 415 V, 50 Hz, A.c. Supply Operation Cycle 30 To 40 Mintutes Complete Connection Etc As Required, Sitc Of Hydro Extractor Machine Direct- Driver Self- Balance With Automatic Electromangnetic Dc Injection Brake System Having Capaciy Of 30 Kg Per Charge With Auto -timed Top Loading Vibration Less Innner Basket And Outer Drum Stainless Steel Complete With Specially Designed Electric Motor And Control Panel Operator On 415 V,3 Phase , 50 Hz Ac Supply . Operation Cycle 5 To 10 Mintes Complete Connection Etc As Required., Sitc Of Drying Tumbler Machine Front Loading Open Pocket, Electrically Heater With Loading Capacity Of 30 Kg . Per Charge Complete With Micro Controller Base Cyclic Timer For Auto Timed & Auto - Reserver, Auto Digital Temperature Control, Fitted With Control Panel , One Motor Each For Driver And Blower Double Walled Glass Wool Insulated Outer Body Mild Steel With Inner Basket Stainless Steel, Self Lint Screen , V Belt Driver Waster Air Exhaust Etc Operates On 415 V, Phase 50 Hz Ac Supply . Operation Cycle 40 To 60 Mintes Complete Connection Etc As Reqd, Supplying And Drawing Following Sizes Of Frls/hffr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required.a) 3 X 4 Sq. Mm, B) 6 X 4 Sq. Mm, Supplying And Fixing Of Following Capacity, 240/415 Volts, 10ka/15ka C Series Mcbs Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc As Reqd.a) 40a, 10 Ka , Fp Mcb (415v), B) 63a, 10 Ka , Fp Mcb (415v), Supplying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Complete As Required.a) 4x 16 Sqmm, B) 4x 25 Sqmm, Supplying, Installation, Testing & Commissioning Of Led Surface Mounted Batten Light Of Following Body Material And Construction As Per Is : 10322 With Driver (replaceable) As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140- 270 Volt, Frequency 50/60 Hz, Operating Temp Range -5 C To 40 C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10%, P. F. 0.95, Ip20, Cri >80, Flicker Free, (flicker Shouldbe Below 5 %), Life Time (led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000 K / 4000 K / 5700 K /6500 K (as Per Ansi Bin), Sdcm(standard Deviation Colour Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/c External Connections With 1.5 Sq Mm Frls/hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy 105 120 Lm/watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-in-charge As Per Requirement. (thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90 C). Powder Coated Die Cast /extruded Aluminium Body (thickness > 1.20 Mm)a) 40 Watt, Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Follow
Ownership :
Sector :
Tender Values
Value :
1,410,230
EMD :
28,205
Doc. Cost :
NA
Important Dates
Due date :
09 Feb, 2026
Open date :
09 Feb, 2026
Publish date :
29 Jan, 2026
Location
Location :
Delhi - Delhi ( IN )
Connect us via What's Up