Web Analytics Made Easy - StatCounter

Gujarat University Tenders - GU Tenders

Get complete information related to latest Gujarat University Tenders - GU Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Gujarat University Tenders - GU Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Gujarat University Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :41015661 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For supply of digital duplicators (v4)

State Government

CTN :40730358 Due date: 16 Jul, 202516 Jul, 2025 64.50 Lacs
Tender For corrigendum : supply, installations etc. of circular dichroism cd spectrophotometer under the coordinator, prof. prodeep phukan, dst-purse project, department of chemistry, gauhati university

State Government

CTN :40902916 Due date: 25 Jul, 202525 Jul, 2025 NA
Tender For supply of technical lab setup d d - data-intensive processing unit , advanced engineering workstation , network storage unit , high-performance desktop , enterprise portable computing device

State Government

CTN :40879785 Due date: 21 Jul, 202521 Jul, 2025 59.54 Lacs
Tender For construction of boundary wall along with internal campus road from teachers qtr 75, gu to apdcl office including other associated works

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso
 Loading, Please wait...

Connect us via What's Up