Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For sic of submersible pump set and all allied e/m equipment for rebored tube well near h.no.-116c shahpur jat in greater kailash constituency ac-50. - supply of submersible pump set fitted with dynamically balanced ss impeller mounted on stainless steel shaft with protection sleeve having stage bowl & closed grained shorted type impeller, the pump will be directly coupled to required wet type induction motor of 7.5 hp, 10 stage, speed 2900 rpm suitable for operation of 3 phase, 415 volt, 50 hz, ac supply with efficiency 70% at following duty point:200 lpm on 90 mtr. head. having discharge outlet 50 mm and outside dia 142 mm.make: bs/skope/ any djb approved make, supply of hut type electrical feeder pillar / fabricated with 50 x 50 x 6mm angle iron and 16 swg ms sheet with horizontal and vertical intermediate member of suitable size. i.e. 1370 mm x 760mm x 460 mm. with arrangement for mounting of switchgear and electrical energy meter i.c. painting heaving following item fitted.a) mccb 63 amp, 4pole, 415volt, 35 ka -1 no.b) rccb 63 amp, 4pole with earth fault indication protecting a circuit automatically in the event of earth leakage sensitivity 100ma, - 1 noc) fully automatic star delta starter of relay range 13-21 amp. (7.5 hp to 10 hp) 3 phase oil immersed type -1 no.d) ampere 96 x 96 mm. square shape 0-30 amp-1 no.e) voltmeter 96 x 96 mm. square shape 0-500 volt-1 no.e) indicating lamp (a set of 3 lamps) 1.setf) shunt capacitor of 10 kvar mpp type with three phase isolator with suitable bankingg) motor protection assembly with earth leakage protection phase sequence corrector, single phasing, protection, overload protection, high voltage / low voltage protection time delay power on, programmable time switch i.c. r&b phase facility to change over from automatic, to manual &vice verse for up to 10 h.p -01 nos. complete wiring & installation of above accessories with required copper conductor wire and thimble etc. 01 job.make of all components: any djb approved., s/o pvc insulated & pvc sheathed cable with plain copper conductor having 3 phases, 3 core flat for submersible motor of 4 square mm size each 100 mtrs.make:grandlay / havells./any djb approved make, s/o m.s. clamp of 600 mm length duly fabricated out of 12.5 mm thick 75 mm wide, m.s. plate for holding the pipe of 50 mm dia., s/o double flange gi column pipe 50 mm dia medium class each of 3 mtrs long duly threaded on both ends, welded fitted with gi flange on both ends with slot of submersible cable. make: tata/ jindal./any djb approved make, s/o/ tail piece of the medium class gi pipe 500 mm long with one end threaded as per outlet of pump & another end flanged as per size of gi pipe 50 mm dia., s/o gi 90 bend of size 50 mm dia having both side flange (heavy duty)., s/o nut & bolts of 1/2 dia of different size i.e. 1.5 dia& 2.5 long full threaded., s/o rubber packing for 50 mm dia flange., fabrication and supply supply of bore cover approx size 8-10 inch diameter made out from 6mm thick m.s. sheet in 2 halves & a circular hole in centre 3-1/2 dia. with locking arrangement by nuts & bolt., earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required., providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required., installation of t/well by lowering of sub p/set with all allied above items. this includes installation and grouting of panel boards with all electrical wiring & cabling at site. all tools & tackles i/c. tripod chain pulley blocks etc. shall be arranged by the firm. this includes testing & commissioning of t/well on load at site i/c. cartage, loading & unloading of material. it also includes a trial run of 30 hrs operation successfully by the firm. all required civil work included in the scope of work.
Tender For supply, installation, testing and commissioning of radar type pressure transducer of 2 nos. pump sets at jaitpur village bps under badarpur constituency ac-53. - supply of digital pressure transducer, range 0-16 kg/cm2, connection 1 4 bsp (m), body ip 65, accuracy +/- 0.5%, output 4-20 ma, input 24v dc, operating temperature -20deg. to 80 deg. c, deviation 0.3%, protection cover for digital pressure transducer. supply of 7 segment indicator with 4-20 ma input, 4 digit indicator, character size 4 inch with provision of decimal, provision for wall mounting / hanging, ms body with powder coating. supply of 2 core x 1.5 sq mm cable approx 25 mtr. installation, testing and commissioning charges including all the electrical work to be done installation of switch, socket in the gang box (waterproof pvc), pvc pipe for all the wiring and the interconnections between the transducer and indicator. make: skope/ vega/seimens/eip/djb approved
Tender For corrigendum : preparation of dpr for the shore protection works in uttara kannada district as recommended by shoreline management plan karnataka prepared by ncscm chennai
Tender For a/r & m/o civil works of baner power house division hpsebl, jia. sub head:- tender for grass cutting around the area of penstock, surge shaft, protection work, fixing of glass panels in the power house building windows & providing and laying of water supply line to switch yard etc. under baner power house division hpsebl jia for f.y 2025-26.
Tender For 1 tender for protection work wire create sp str pole no 23 of 11 kv ht line ganagth feeder in jabbar khad at jassur under esd ganoh ts no 63 2025 26 2 tender for protection work wire create sp str pole no 24 of 11 kv ht line ganagth feeder in jabbar
Tender For protection of spillway channel towards basati nallah rd 123 to 130 m by providing wire crate wall and cement concrete work which was damaged due to heavy rainfall during monsoon 2025
Tender For construction of c.c. lining work of main canal at rd 1290 m to 1540 m of selected patches, repairing and construction of fall and construction of outlet at rd 300m, construction of c.c. lining work of sub minor on selected patches and construction