Get complete information related to latest Meters Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meters Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meters Tenders.
Tender For auction sale of mild steelscrap (dismentalled hframe loc no 42(s) & 43(s) of g6kv vakha-raiya,air compressor tank 02 nos,flashed disc insulator,oil filter machine nirmal with carrier model,misc. old 3 phase electromechanical type energy meter & relay,acsr panther conductor,66kv ct scrap 600-300/1,66kv ct scrap 100-150/1,ms scrap vcb panel,66kv ct scrap 400-200/1,as above - dog conductor scrap,as above- disc insulator metal parts scrap,empty oil barrels 209 ltr. capacity (serviceable),ms scrap(earth wire and hardware scrap,ms scrap(assorted old material,3-phase electromichanical type meter & relay,empty oil barrel(serviceable) 209 ltr,m s scrap earth wire,ms scrap earth wire,66kv ct,ms tower scrap (dismentalled from 400kv charanka- veloda line tower no 22),lead battary cell,al 59 conductor scrap(dismentalled from 220kv charanka-jangral line loc 25-28),ms tower scrap
Tender For corrigendum : supply of 11kv and 33 kv outdoor oil cooled metering unit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled metering unit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges
Tender For auction sale of scrap gos,11kv 3 core ug cable,scrap released ht metering cubicle distribution boxes, feeder piller boxes etc,scrap i beam / ms rail pole,scrap iron 2 leg / tubular / tower poles,scrap rcc poles skeleton,scrap iron,scrap aluminium bus bar / wire pieces,scrap gi pins,scrap ht / lt ctcs,scrap three phase energy meter high precession (fibre body),scrap three phase etv meter [static meter] e waste
Tender For auction sale of scrap skeleton,scrap lt/ht metering box, distribution box etc,scrap 3phase energy meter static (electronic) e-waste,scrap 3 phase static e-tv energy meter (electronic) e-waste,scrap iron rail pole / i beam pole,scrap iron tubular / ladder pole,scrap iron,scrap gos,scrap 33/11kv ug cable
Tender For corrigendum : ridf xxviii - lift irrigation projects in various padashekharams of wayanad district- procurement of submersible pumpsets, fittings, accessories, and related electrical works - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses. - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses., supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontally mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day night operation.the pump discharge capacity of 230 cubic metre /hour against duty point head of 42 mtrs, working head range 18 - 47m, discharge range 136 - 57 lps ,speed 1450rpm(n) or nearer ,with 10meters of copper power cable and control cable, railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided with an additional iron grill for preventing foreign particles inside the inlet side of the pump casing., supply and erection of 60hp auto transformer starter (ats) with suitable incommer and contactors including 24 kvar capacitor with required indications ,metering and protections for single phasing ,overload, pump monitoring unit to protect from ingress, high temperature level etc enclosed in a closed panel board, supply and laying additional termination cable of 1.1kv 3.5 core 95sqmm aluminium conductor xlpe insulated ;steel armoured ug cable as per relevant is 7098 with support for cable, supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontzlly mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day nightoperation.the pump discharge capacity of 188 cubic metre /hour against duty point head of 35 mtrs,working head range 16 - 42m, discharge range 102 - 42 lps ,speed 1450 rpm(n) or nearer ,with 10meters of copper power cable and control cable,railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided wi