Get complete information related to latest Soil Survey Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Soil Survey Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Soil Survey Tenders.
Tender For conducting detailed physical survey and superimposing the same on the sajra plan by g.p.s enabled total station equipment in gps system of the various dda vacant plot and gram sabha land in jurisdiction of emd-7
Tender For rfp for providing service and executing geotechnical survey and soil testing of atal innovation studio sites at udaipur, bharatpur and bikaner
Tender For strengthening and establishing 46 nos. water quality testing laboratory in water treatment plants (wtp)/ulb under watco and water quality monitoring for the period of ten years on lump sum contract
Tender For corrigendum : (jjm)-jal jeevan mission phase ii-2022-2023 wss to thiruvillwamala, kondazhy and pazhayannur panchayaths-soil exploration test at proposed wtp site - construction of 15 mld water treatment plant at kuthampully (ls)-general civil work
Tender For custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..
Tender For carry out survey and preparation of details plan, proposal for land acquisition and demarcation of prow as per land acquisition plan on four lanning of radhanpur-lodra-morvada-suigam road 0/00 to 25/00 (sh-861) under jurisdiction of r & b sub division, radhanpur. (existing row to 45m row) (2nd attempt)
Tender For supply of 2 megapixel or above bullet camera , 24 port switch poe as per specifications , biometric fingerprint scanner secugen hamster pro 20 , cat 6a io box with faceplate , cat 6a cable each box 305 mtrs , pvc conduit pipes 2 inches , ip66 outdoor camera boxes , jack panel cat 6a fully loaded 24port , patch cable cat6a 1 meter , patch cable cat6a 5 meter , led industrial monitor 42 inches or above , camera application software with licenses perpetual , higher end server with 32 gb ram 2 tb ssd or hdd for os with 4 gb graphics card and storage of 24 tb hdd usable latest version server os , 24 u floor mounted rack with all accessories exhaust fan power manager and hangers etc , ups 5 kva , soft soil digging , installation testing, commissioning charges for the above