Web Analytics Made Easy - StatCounter

Ac Pipeline Laying Tenders

Get complete information related to latest Ac Pipeline Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Pipeline Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Pipeline Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42216517 Due date: 10 Oct, 202510 Oct, 2025 2.58 Lacs
Tender For deeping the existing 600mm dia ci pipe line with laying of 600mm dia ms pipe line to avoid interference with other infrastructure i.e., sw drain opposite at h.no.20-4-199/2/a near shah talkies road, shalibanda under misrigunj section, sub division-iv of operations and maintenance division-i

State Government

CTN :42216518 Due date: 10 Oct, 202510 Oct, 2025 1.88 Lacs
Tender For deeping the existing 450mm dia ci pipe line with laying of 450mm dia ms pipe line to avoid interference with other infrastructure i.e., sw drain opposite at h.no.20-4-199/2/a near shah talkies road, shalibanda under misrigunj section, sub division-iv of operations and maintenance division-i

State Government

CTN :42216519 Due date: 10 Oct, 202510 Oct, 2025 4.05 Lacs
Tender For deeping the existing 675mm dia ci pipe line with laying of 675mm dia ms pipe line to avoid interference with other infrastructure i.e., sw drain opposite at h.no.20-4-199/2/a near shah talkies road, shalibanda under misrigunj section, sub division-iv of operations and maintenance division-i (reserved for sc contractors only as per g.o.ms.no.59, i and cad (reforms) department dated:21.05.2018)

State Government

CTN :41968734 Due date: 14 Oct, 202514 Oct, 2025 4.08 Crore
Tender For upgradation of existing diesel pump room by supplying, installation, testing and commissioning of mix-flow type electric pump sets and silent diesel generator sets with laying of 600 mm dia. m.s. pipe line including electrification etc. at sonia vih

CTN :42193029 Due date: 24 Oct, 202524 Oct, 2025 NA
Tender For laying and jointing of 150 mm ms pipe line 07 mtr. in ward 02 kacchi basti.

State Government

CTN :41758283 Due date: 13 Oct, 202513 Oct, 2025 2.17 Lacs
Tender For corrigendum : ktps v vi stages - civil-om-i-laying of rcc flooring in place of damaged portion at mills rejected coal platform and providing cement mortar lining over ms pipe line of 2.20 mtr dia at natural draft cooling tower and of ktps vi stage, paloncha

CTN :41541554 Due date: 06 Oct, 202506 Oct, 2025 NA
Tender For bid to ras supply of rfid radio freq iden sys for bpet and ppt c c - start and finish line ms pipe structure , 4 port controller , uhf reader 4 port , check point structure , 2 port controller , uhf reader 2 port , uhf card , media converter , 8 port ethernet switch , 8 port sfp switch , 5mp ip camera , database management and reporting , 24 core armoured fiber cable , installation, cable laying and network integration

CTN :41968812 Due date: 07 Oct, 202507 Oct, 2025 3.73 Lacs
Tender For corrigendum : dismantling and laying of 8 inch dia ms pipe line for dewatering of coal face at dept patch and shifting and re installation of pumps accessories after shifting work by cutting/welding as per requirement based on progression of face at dept patch ask

CTN :42093010 Due date: 20 Oct, 202520 Oct, 2025 NA
Tender For tender for supply of supply installation and commissioning of fully inverter type ivrf ac unit : : - supply of vrfv plus air conditioning system with energy efficient fully inverter scroll type compressors capable of delivering 100 % capacity at 43degree ambient and capable operating between 320v 460v with high performance oil accumulators self diagnostics redundant outdoor unit and indoor units.ivrfb 22tcn , indoor units with all supporting materials for hanging and fixing for existing duct. a. 6tr ducted indoor , b. 8tr ducted indoor , c. corded remotes , d. cordless remotes , installation , nitrogen pressure testing , vaccumising and commissioning of vrf odu units , installation charges for ducted indoor units , supply and laying of hard drawn copper refrigerant piping with elbows , couplings , reducer and slotted supports for suction and discharge line , supply and fixing of 19mm and 13mm thick nitrile rubber insulation for above copper pipe and ppe covering with fire retardant tape , refrigerant gas charging r410a , lifting , shifting and erection of ivrf outdoor units , communication cable for idu to odu , drain pipe cpvc with insulation , ms channel stand for odu units , scaffolding charges , dismantling charges for existing indoor units , dismantling charges for existing outdoor units , canvas fire proof for connection between indoor and cool air duct connection

Central Government/Public Sector

CTN :41759290 Due date: 07 Oct, 202507 Oct, 2025 21.63 Lacs
Tender For corrigendum : tender for supply of 33kv line maintenance between jaduguda and narwapahar for two years : : - replacement of 33kv pin insulator including supply of necessary fixing materials. this includes binding of acsr dog conductor also , replacement of 33kv disc insulator including supply of necessary fixing materials in existing 33kv line , replacement of 33kv cross arm including supply of necessary fixing materials , replacement of packing pieces in existing cross arms , replacement of pg clamp for dog conductor including supply of necessary fixing materials , installation of complete stay set including supply of necessary fixing materials. this includes digging of stay pits and grouting of stay rod in cement concrete foundation also as required , installation of gi wire 7/10 swg for stay including supply of necessary fixing materials , installation of gi wire 8 swg for guard wire , installation of gi wire 7/14 swg for earth wire including supply of necessary fixing materials , replacement of back clamp for cross arm & top bracket (50mm x 10mm flat) including supply of necessary fixing materials , installation of d.p. channel (100mm x 50mm x 6mm) 1 x 3 mtrs including supply of necessary fixing materials , installation of d.p. channel support clamps including supply of necessary fixing materials , replacement of earth clamps for earth wire including supply of necessary fixing materials , replacement of side stay clamp including supply of necessary fixing materials , replacement of angle stay clamp including supply of necessary fixing materials , replacement of cross bracing for d.p. structure including supply of necessary fixing materials , replacement of clamp for x-bracing including supply of necessary fixing materials , installation of earthing pit using pipe earth electrode as per drawing including connection to earth wires and supply of necessary materials required it , laying & tensioning of acsr dog conductor including fixing / binding at insulators in the 33kv line (per km consist 3 conductor of ryb phases). , tensioning of dog conductor and supporting & fixing on insulators including binding as required in the section (per km consist 3 conductor of ryb phases). , cutting and removal of hages , trimming of trees and branches of size more than 4inch dia and disposal of un-serviceable materials to ucil canteen building as per direction of eic , cutting and clearing jungle grass including uprooting of rank kegetation , long grass , bush wood , trees and saplings upto 4inch dia measured at a height of 1 meter above ground level as per direction of eic , erection of m.s. rail pole 105 lbs , 13 meters long including drilling of 2 nos holes of 5/8inch dia as required at one end of rail pole for fixing of f- clamps , installation of ab switch on double pole structure. this includes fixing of required channels and clamps and other fixing as required and for proper operation. this includes connection of dog conductor alsodog conductor also , installation of 33kv lighting arrestor on double pole completed with line and earth connections , maintenance of ab switch on double pole structure , 33kv line patrolling from narwapahar to jaduguda , replacement of earth spike along the 33kv line & connection to pole , number of rail pole with painting of pole upto 6 feet height for colour coding of line
 Loading, Please wait...

Connect us via What's Up