Get complete information related to latest Ac Wiring Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Wiring Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Wiring Tenders.
Tender For bid to ras corrigendum : supply of split ac at bsnl surendranagar oa : - cm of 1.5tr non inverter split ac units , replacement of blower fan motor in 1.5 or 2 tr ac unit , replacement of blower drum in 1.5 or 2 tr ac unit , replacement of condenser fan motor in 1.5 or 2 tr ac unit , replacement of condenser fan blade in 1.5 or 2 tr ac unit , pcb repair for indoor unit of 1.5 or 2 tr ac unit , pcb repair for outdoor unit of 1.5 or 2 tr ac unit , replacement of 1.5 tr rotary compressor in 1.5 tr ac unit , replacement of 1.5 tr rotary compressor in 2.0 tr ac unit , replacement of 25 or 35 mfdcapacitor in 1.5 or 2 tr ac unit , replacement of 2 pole 25 amp contactor for 1.5 or 2 tr ac unit , replacement of 4 or 6 way terminal box for 1.5 or 2 tr ac unit , water service for 1.5 or 2 tr ac unit , blower service for 1.5 or 2 tr ac unit , charging or topping up r22 or r134 gas in existing 1.5 or 2 tr ac unit , replacement of 50mm thick synthetic air filter for 1.5 or 2 tr ac unit , sitc of auto sequential micro controller for 2 no split or window ac units , replacement of faulty 25 a sp mcb in existing db for 1.5 or 2 tr ac unit , site visit for ac fuult clearing with minor repair
Tender For corrigendum : supply of air conditioner e e - gas check-up pressure testing , full gas charging , nitrogen pressure testing , internal leakage repair , water leakage repair , drain pipe replacement , insulation refixing , copper condenser coil split , copper condenser coil window , copper cooling coil split , cooling coil repair , new compressor , replacement compressor old , pcb repair inverter , pcb repair non-inverter , pcb replacement universal with remote , capacitor , contactor , sensor transfomer fuse replacement , fan motor , blower motor , motor bearing chenge noise adustment , swing flap motor blade replacement , new ac installation , ac uninstallation , outdoor indoor reinstallation , copper piping with insulation and wire , foam jet deep ac service , lite ac service , anti-rust spray external cleaning , visiting or inspection charge
Tender For bid to ras supply of 2 ton all weather split air conditioner , stabilizer 4 kva , outer stand for ac , wiring of ac , complete installation and commissioning
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 006 during boat davit operations smoke observed from control transformer in control panel; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 013 port blower of water jet compartment is not getting start zero insulation measured suspectd winding burnt; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 022 contactor coil switch burn out; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c 423; l 023 defect rectification of maine engine charger; service provider
Tender For providing of facility management services - lumpsum based - name of work repair & maintenance infrastructure assets during the year 2025 26 sub head supply, installation, testing and commissioning of ml 12 power contactor at various locations under rl division; name of work repair & maintenance infrastruc..
Tender For urgent repair of 2no. horizontal split casing pump sets along with replacement of defective soft starter, mccb, contactor block and repairing of ocb and resistance regulator at water works sector 39, chandigarh
Tender For supply of contactor repair kit for radiator cooling fan contactor 325 amp, 03 pole to emd part no 40037904 as per eaton part no 6.45.2.as per list atteched of hhp locomotive.consisting 07 items.toblw drg. no. 4003790. [ warranty period: 30 months after the date of delivery ]
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required