Get complete information related to latest Access Door Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Access Door Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Access Door Tenders.
Tender For supply of sensor 1 no- of each type for sl no 17 and 18 , l8012s5789701001 -elec atuator for buf inlet sa30point1b1 90-gs400 , l8012s5789701002 -elec atuator for buf inlet sa30point1b1 90-gs400 , l8012s5789701003 -elec atuator for buf outlet sa35point1b3 90-gs400 3 , l8012s5789701004 - elec atuator for buf outlet sa35point1b3 90-gs400 , l8012s5789701005 - electronic pcb for actuators for sl no 22 and 24 , l8012s5789701006 -absolute encoder for actuators for sl no 22 and 24 , l8012s5789701007 - electronic torque sensor for actuators for sl no 22 and 24 , l8015s5789701001 - electrical gate actuatorfgd buf inlet- lh as per s- no 1 of datasheet , l8015s5789701002 -electrical gate actuatorfgd buf inlet rh as per s-no 2 of datasheet , l8015s5789701003 -electrical gate actuatorfgd buf inlet lh as per s.no 3 of datasheetref , l8015s5789701004 -electrical gate actuatorfgd buf inletrh as per s.no 4 of datasheet , l8015s5789701005 -electronic pcb for actuators for si-no 29 - 31 , l8015s5789701006 - absolute encoder for actuators for si-no 29 - 31 , l8015s5789701007 - electronic torque sensor for actuators forsi.no 29 - 31 , l7014s5789701001 - model- sa50e180-gs200-gz16 , l8020s5789701001 - electrical actuator sa25point1b190-gs315 , l8020s5789701002 -electrical actuator sa30point1b390-gs315 , l8020s5789701003 - electronic pcb 1 no of each type for sl no 37 and 38 , l8020s5789701004 -absolute encoder 1 no of each type for sl no 37 and 38 , l8020s5789701005 - electronic torque sensor 1 no of each type for sl no 37 and 38 , l8024s5789701001 -electrical actuator sa25point1b4 180-gs315-gz30 , l8024s5789701002 - electrical actuator sa30point1b1 90-gs400 , l8024s5789701003 - electronic pcb 1 no of each type for sl no 42 - 43 , l8024s5789701004 - absolute encoder 1 no of each type or sl no 42 - 43 , l8024s5789701005- electronic torque sensor 1 no of each type for sl no 42 - 43 , l8041s5789701001 - model- sa30point1b3 180 -gs400-gz35 , l8041s5789701002- electronic pcb for sa30point1b1 90- gs400 , l8041s5789701003-absolute encoder for sa30point1b1 90-gs400 , l8041s5789701004- electronic torque sensor for sa30point1b1 90-gs400
Tender For provision of electrical arrangements in connection with 1) replacement of mechanically operated lifting barrier with electrically operated lifting barrier at lc gate nos. 7, 53, 39, 83, 99, 77, 125, 129, 121, 163, 29 & 171 of nanded division. 2) interlocking of lc no. 72 between bdu-jalna stations, lc 168 between bmf-mrv, lc 37 between lsr-poz stations over nanded division.
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For corrigendum : supply of repair of high definition camera with ni vision capability poe ip , utp cable cat 6 , nvr with i p and 2 tb hard disc 16 port , repair of ptz programming console , repair of display monitor 40 inch , repair of boom barrier with tyre killed , ptz camera 100 mtr , repair of mega phones , repair of license plate camera , repair of rfid sys with lan , repair of rfid cards with lanyard , switch 24 port 1000mbps , repair of management console , repair of servers , repair of biometricd gate lock , repair of search light , repair of hhm detector , electrical siren 2 km , repair of integrated racks , repair of ups 1 kva offline , repair of ups 5 kva online with 1 hrs backup , ofc 4 core , monitor 18.5 inch , hand held rfid system , repair of door frame metal detector , media converter
Tender For 36 mld stp bahadurgarh town, providing various electrical and mechanical components at 36 mld stp of bahadurgarh town and all other works contingent thereto. - providing and fixing of electrical lt ats control panel (heavy duty) suitable for running of 130 bhp submersible non-clog pump set for sewerage with full load curfrent 171 amp, power 415 vt 3 phase at 36 mld stp of bahadurgarh town., repair of 2 nos. air blower complete in all respect (including replacement of parts), repair of automatic sluice gate of sbr reactor no. 4 complete in all respect., providing and fixing of 16 sqm 3 core dual pvc sheathed copper cable of isi make at 36 mld stp bahadurgarh town for 65 bhp motor(make: finolex/havells/national), providing and fixing of 16 sqm 4 core dual pvc sheathed copper cable of isi make at 36 mld stp bahadurgarh town for 65 bhp motor(make: finolex/havells/national), providing and fixing of 50 sqm 3 core dual pvc sheathed copper cable of isi make at 36 mld stp bahadurgarh town for 130 bhp pump set(make: finolex/havells/national), providing and fixing of 50 sqm 4 core dual pvc sheathed copper cable of isi make at 36 mld stp bahadurgarh town for 130 bhp pump set(make:- finolex/havells/national)
Tender For a/r & maintenance of for renovation of entrance gate no. 1 at ncert campus, new delhi (sh: civil & electrical works)subwork/packages:a/r & maintenance of for renovation of entrance gate no. 1 at ncert campus, new delhi (sh: civil & electrical works)
Tender For corrigendum : supply of electrical fencing - single zone energizer , external hootor , ac charger controller unit , battery , lightning diverter kit , fence live light , outdoor console rack , inter mediate posts , corner and end posts , support pole , intermediate post insulators , end strain hooks , end strain insulators , joint clamps , fine pitch wire strainer , ht wire , double insulated cable , warning sign board , earthing , gate top electrification , service fence erection , service post welding , freight and insurance
Tender For procurement of electrical components and minor equipment for lab - single-phase auto transformer (0-270v, 35a), three-phase voltage sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes, three-phase current sensors (used for both ac and dc sensing capability) with high accuracy along with dso probes, three-phase autotransformer (440v, 40a), powering boards for sensors and gate driver circuits (15v, 12v, 5v), soldering iron with controllable temperature - medium (weller), gsr 120-li small rechargeable driller (bosch), lrs-600-12 dc power supply/smps mean well 12v, 50a, 600w, lrs-600-15 dc power supply/smps mean well 15v, 40a, 600w, lrs-600-24 dc power supply/smps mean well 24v, 25a, 600w, lrs-600-36 dc power supply/smps mean well 36v, 16.6a, 597.6w, lrs-600-48 dc power supply/smps mean well 48v, 12.5a, 600w, fluke multimeter 0-600v, 0-10a, rheostat 200 ohm, 20a, tektronix a622 ac/dc current probe, skkt 107/16 e- thyristor modules (1.6kv, 119a), scr module heat-sink, scr firing module, inductor filter (50a), mccb (60a), ganged potentiometer (5 ??, 3watt), digital panel mount ammeter (75a), digital panel mount ammeter (1000v), 10sq mm wire, dc shunt (75mv, 75a), lugs, hardware (base plate for scr module), single sw sic-mosfet module, sic-mosfet switches (silicon carbide mosfet, single, n, channel, 55 a, 1.2, kv, 0.075 ohm, to-247), single sw sic-mosfet gate driver, 10a igbt and sic mosfet gate drive with integrated overcurrent sensing, fault, and uvlo status feedback features acpl-, 355jc based design