Get complete information related to latest Accuchek Instrument Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Accuchek Instrument Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Accuchek Instrument Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :38075037 Due date: 18 Dec, 202418 Dec, 2024 17.50 Lacs
Tender For bid to ras supply of installation of 16 meter led security high mast light - supply install and testing 16 meters, high mast with double drum winch and stainless steel rope , earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6 mm , supply and fixing led flood lights luminaire with secondary optics made in pressure die cast housing and heat sik in aluminum extrusion of 1 x 210 watt led light fittings ip-67 and ip 68 , supply, laying, jointing and testing lt, xlpe insulated, armored heavy duty cable with stranded aluminum conductor suitable for rated voltage of 1100 volts grade , excavation in trenches in soft or loose soil , returning, filling in with excavated soil, including spreading, leveling, watering and well ramming in layers , removing excavated material soil , m and l for sand cushioning to pvc or xlpe cable , 32 mm pvc sanitary pipe for covering 11kv heavy duty cable , m and l for brick protection over to lt underground cable , supply, install, testing and commissioning of lt panel of size 60 cm x 60 cm x 6 mm cm outdoor

State Government

CTN :38582182 Due date: 06 Jan, 202506 Jan, 2025 52.91 Lacs
Tender For on risk & cost piped water supply scheme for village-chando(schooltola)block- balrampur, district balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 30 kl capacities 01 no. & staging 00 mtr, oht repairing {steel structure 12 m height & 10 kl (5000l x 2no.) 00 no. and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} of total - 00 nos. pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 600 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 1550 m., 110 mm dia. 00 m., 140 mm dia. 1710 m. 160 mm dia. 470 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1201 m., 75 mm dia. 636 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4/6 tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 76 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under piped water supply scheme under jal jeevan mission for village-chando(schooltola)block- balrampur, district balrampur(c.g.)

State Government

CTN :38582184 Due date: 06 Jan, 202506 Jan, 2025 25.64 Lacs
Tender For on risk & cost piped water supply scheme for village-aanandpur(sadakpara),aanandpur(purabtola),block-ramchandrapur, district balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 45 kl capacities 01 no. & staging 12 mtr {steel structure 12 m height & 10 kl (5000l x 2no.) 00 no. and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} of total - 00 nos. pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 2446 m., 75 mm dia. 1459 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4/6 tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 119 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under piped water supply scheme under jal jeevan mission for village- aanandpur(sadakpara),aanandpur(purabtola),,block- ramchandrapur, district balrampur(c.g.)

CTN :38411116 Due date: 21 Dec, 202421 Dec, 2024 15.1 Thousand
Tender For design, engineering, manufacture, testing at shop, transportation, supply to site, handling/loading to work front of inside lining material ( both bricks and castable) together with all accessories, mortar material, surface preparation, preparation of brick shape to suit the equipment dimensions/ drawings, shuttering, application, curing as per manufacturer instruction and demonstration of performance of inside calciner lining with bricks for 22 meters, castable -lc45 for 8 meters, cc 90 on burner duct

Central Government/Public Sector

CTN :38456986 Due date: 26 Dec, 202426 Dec, 2024 40.00 Lacs
Tender For repair/ replacement of lt underground cables and connected items in various locations at mil stn yol - excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed., excavation in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr but not exceeding 3 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard dense soil, complete all as specified and directed., returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed., removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed., pcc 1:3:6 (nominal mix) type c-2 (using 40mm graded crushed stone aggregates) as in coping of pole including necessary form work complete all as specified and directed., pcc 1:4:8 (nominal mix) type d-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed., sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cms thick, complete all as specified and directed note: punned thickness shall be measured., sub class b brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed., laying only bricks along the length of cable on sand cushioning, with width equal to the length of the brick , complete all as specified and directed., mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with ms clamps, nuts and bolts required complete all as specified and directed., mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with ms clamps, nuts and bolts required complete all as specified and directed., dismantling poles/struts, any size and type including insulators and removing from site, complete all as specified., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 300 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 240 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe insulated screened and pvc sheathed armoured electric power lt cable heavy duty with aluminium conductor nominal cross sectional area 185 sqmm 3.5 core for working voltage upto including 1100 volts conforming to is-7098 (part-i) 1988 including taking out existing unserviceable cable, complete all as specified and as directed., supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing xlpe i

CTN :38422392 Due date: 24 Dec, 202424 Dec, 2024 NA
Tender For part a interception and diversion (i and d) of network, mps, stp and fstp at bariwala (dnit for providing and laying cutting jointing and testing of 750mm and 400mm i/d di k7, 200mm - 315mm o/d upvc pipe sewer, construction of brick masonry manhol