Web Analytics Made Easy - StatCounter

Acid Analyzer Tenders

Get complete information related to latest Acid Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acid Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acid Analyzer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39369926 Due date: 10 Mar, 202510 Mar, 2025 NA
Tender For supply of digital upright microscope with fluorescence image analysis software - digital upright microscope with fluorescence image analysis software , digital camera , image analysis software , data processor and display system , ups 2kva , dic accessories

Central Government/Public Sector

CTN :38768303 Due date: 23 Feb, 202523 Feb, 2025 2.40 Crore
Tender For corrigendum : supply, installation, testing and commissioning of digital slide scanning system with research grade microscope or image analysis software

CTN :39352109 Due date: 21 Feb, 202521 Feb, 2025 NA
Tender For purchase of ai based metallography image analysis system

Central Government/Public Sector

CTN :39337507 Due date: 06 Mar, 202506 Mar, 2025 NA
Tender For supply of inverted microscope , digital camera , image analysis software , data processor and display system , ups 2kva

Central Government/Public Sector

CTN :39278151 Due date: 03 Mar, 202503 Mar, 2025 NA
Tender For supply of inverted microscope , digital camera , image analysis software , data processor and display system , ups 2kva

CTN :39249204 Due date: 28 Feb, 202528 Feb, 2025 1.35 Crore
Tender For state-of-art fully digital high end latest color doppler echo cardiology system for adult, paediatric and neonatal application with all quantification software's including contrast study, system must be offered with a minimum of 40 lakh digital processed channels. original technical data sheet should be enclosed in technical bid to support the number of channels on the systems. if not mentioned, please attach a letter from manufacturer along with the technical bid clearly stating the digital processed chan nels of the offered system, system should incorporate latest image acquisition & processing technology maintaining uniform spatial resolution, tissue uniformity through complete fov at high temporal resolution resulting high diagnostic confidence. please attach white paper on this technology, system should have broad band beam former capable of processing signals from 1-16 mhz, high resolution main display minimum size 21 inch with wide viewing angle. lnbuilt 12 inch high resolution touch screen user interface capable of image display and complete image processing & measurements, system, control panel, and monitors mounting should have continuous height and angle adjustment for operator comfort especially suitable for multiple -user depts. with high patient load., system should incorporate facility for high r~solution 2d, m mode, pw, cw doppler color flow imaging, color power angio imaging with high frame rate of min 1900fps for 2d & 200 fps for color imaging, system should have full spectrum imaging, speckle reduction filter, spatial compound imaging, phase inversion tissue hannonic imaging, trapezoidal imaging &contrast enhanced imaging(low-mi), system must be offered with speckle reduction imaging: image processing technique to remove speckles and clutter artifacts., system should have strain quantification imaging, including strain assessment for la, lv and rv, split screen view with independent cine loops & cfm. simultaneous b mode& b color mode., 2 d measurement should include calipers for distance/ depth, angle, areal circumference by ellipse/trace etc, integrated stress echo facility to perform stress echo exams., system should have real time triplex mode facility in 2d, color and doppler modes., system should have dynamic modes of 270db or higher, system should have high prf(mention rate-highest will be preferred), system should have scan depth of i to 40 cm or more. please specify through data sheet, system should have 256 shades of grey display, system should have facility for real time and frozen, pan or point zoom. cine loop as well as cine scroll facility in b mode., system should support single button to customize the workflow of doctor., system should have independent steering ofb mode and color on linear probe, system should have individual operator specific atomized workflow protocol which lets operator focus on patients, dedicated sdd of min 512gb for os for fast boot up and separate hdd for patient image storage min 1 tb, system should include anatomical mode, cardiac quantification software including auto ef, tdi, tdi quantification, and stress and strain., system should have contrast imaging with quantification for lvo study and myocardial analysis, system should include auto imt measurement and preferably based on real time data, possibility to modify/edit patient data during and after exam has been completed., system should min 8 point tgc and separately lgc dedicated cardiac applications, system should include integrated report generation sw included choice of embedded images, systems should have standard minimum 4 active probes connectors with electronic switch facility from key board. it should be provided with following transducers. a. adult single crystal phased array probe 1.5 to 4 mhz b. pediatric cardiac phased array probe 3 - 8mhz c. neonatal transthoracic transducer 4-12 mhz d. 3d tee transducer 2 - 7 mhz matrix! single crystal technology with biplane imaging and mini
 Loading, Please wait...

Connect us via What's Up