Get complete information related to latest Acsr Weasel Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acsr Weasel Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acsr Weasel Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :42850731 Due date: 15 Dec, 202515 Dec, 2025 35.00 Lacs
Tender For corrigendum : rate contract for supply of local purchase of various electrical equipment/goods under 33/11 kv substations under morena circle - buchholz relay for 3.15mva & 5 mva, smart clamp, bimetallic clamp for ptr bushing stud size 20 mm, isolator pad clamp for raccoon & dog conductor, 33 kv bushing for ptr suitable for 20 mm stud (bimetalic clamp suitable for ptr 20 mm dia brass stud weight 1.450 kg), 11 kv bushing for ptr suitable for 20 mm stud (bimetalic clamp suitable for ptr 20 mm dia brass stud weight 1.450 kg), mog(megnetice oil level indicator model-so-6 150 mm suitable for conservator mounting horizontalalarm switch low oil level, mfm suitable for control panel of all makes, c&r panel indicators, ct smart clamp for 16/20 mm stud for raccoon, dog and panthorconductor, expulsion fuse 20 a for capacitor bank ( for 100 kvar unit), expulsion fuse 40 a for capacitor bank ( for 200 kvar unit), brass stud 20 dia suitable for 33 kv bushing (bimetalic clamp suitable for ptr 20 mm dia brass stud weight 1.450 kg), brass stud 20 dia suitable for 33 kv bushing (bimetalic clamp suitable for ptr 20 mm dia brass stud weight 1.450 kg), winding temperature indicator (wti) , dial 150mm , with capilary,mercury swicth type, oil temperature indicator (oti) , dial 150mm , with capilary,mercury swicth type, tnc switch suitable for control panel of all makes, rubberized cork ( gasket) 10 mm, silica gel breather 3 kg casted acrylic plasticbody with silica gel, silica gel blue, conical rubber washer for cts (size 12 mm), conical rubber washer for cts (size 16 mm), conical rubber washer (19 mm), trip coil , shunt type 30 volt dc suitable for bhel make vcb, trip coil for essun make vcb, trip coil for megawin make vcb, auxiliary switch suitable for megawin make 11 kv vcb, auxiliary switch suitable for bhel make 11 kv vcb, 33 kv vaccum interrupter bottle suitable for bhel make vcb, bridge rectifier for battery charger., trip coil 30 volt dc suitable for stelmec, closing coil assembly for stelmek vcb, trip coil suitable for schneider make vcb without assembly, trip coil suitable for cgl make vcb without assembly, limit switch motor for 11kv & 33kv cgl vcb, trip coil with plunger for shreem make vcbs, 33 kv trip coil suitable for stelmec make vcb, auxiliary switch suitable for stelmec make vcbs, spring charging motor for bhel make vcb 220 volt/880 watt, 11 kv vacuum interrupter suitable for stelmec vcbs modeltype/wl/34599m3+, spring charging motor suitable for stelmec make vcbs, spring charging motor suitable for crompton make vcb, 11 kv vaccum interrupter bottle suitable for bhel make vcb, trip coil 30 volt dc suitable for cg/stelmec 33 kv vcb withoutassembly., big gear suitable for stelmec vcb, small gear for stelmec vcb, 11 kv drive rod make magawin, 11 kv drive rod make bhel, 11 kv insulating pull rod 11 kv bhel make vcb, single phase 500 watts hand drill machine bid dia size 2 mm to 10mm, pg clamp dog to dog, pg clamp raccoon to raccoon, ic to dc product, abc powder type fire extinguisher 9 kg capacity isi make, repairing of numerical relay 3oc+1ef, 11 kv insulating pull rod ea 12 make stelmec, 11 kv insulating pull rod ea 12 make essun/shreem, 11 kv insulating pull rod ea 12 make cromption, 11 kv charging handle with gear assl. suitable for stelmec/crompton/bhel make vcb

CTN :43033958 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For the work of shifting of line full deposite scheem at various place under edd-sadabad hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, neutral cum earth wire, cable jointing kit, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap

CTN :43037356 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For the work of construction of line and other associate work under full deposite scheme at various place under eudd-hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, metering cubicle, ct-pt, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, fixing/ errection of following item, cost of labor, material and t&p which required for completion of work, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, metering cubicle, ct-pt, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap

CTN :42099201 Due date: 17 Dec, 202517 Dec, 2025 25.00 Lacs
Tender For corrigendum : tender for the annual rate contract work of laying, commissioning and testing of 11kv ug xlpe cable & erection and maintenance of o/h 11 kv ht line/lt line (with bare conductor, mvcc or abc), transformer center, replacement of bare conductor & its accessories, etc. in various scheme under jurisdiction of sutharpada sub division under dharampur division.

CTN :43100116 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For survey, supply, transportation, carriage, erection, testing and commissioning for laying of lt line on 8 mtr long st poles alongwith acsr weasel conductor at village kohsar w. no. 8 in assembly constituency chenani

CTN :43103280 Due date: 30 Dec, 202530 Dec, 2025 25.00 Lacs
Tender For tender for erection of ht, lt line & t/c structure of o/h line conductor with abc; maintenance of old overhead ht/lt line & tc with dismantling of pole, transformer center&supply, laying, testing and commissioning of 11kv /22 kv ug cable (xlpe cable will be supplied by dgvcl) with cable termination and straight through joints kits (to be supplied by contractor) for laying underground cable in all purpose all schemes at kapodara sub division or any sub division under surat rural division.

CTN :43080470 Due date: 30 Dec, 202530 Dec, 2025 1.00 Crore
Tender For tender for annual rate contract work for tender for erection of ht, lt line & t/c structure of o/h line conductor with abc; maintenance of old overhead ht/lt line & tc with dismantling of pole, transformer center & supply, laying, testing and commissioning of 11kv /22 kv ug cable (xlpe cable will be supplied by dgvcl) with cable termination and straight through joints kits (to be supplied by contractor) for laying underground cable & other related works in all purpose all schemes at puna sdn, saroli sdn or any other subdivision under surat rural division.

CTN :42988395 Due date: 12 Dec, 202512 Dec, 2025 1.00 Crore
Tender For maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numerical (feeder p

State Government

CTN :43018454 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For replacement of acsr weasel conductor to aaac covered conductor from 33/11 kv substation kamaluaganja to 11kv mukhani under electricity distribution division (rural) haldwani.

State Government

CTN :43018455 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For replacement of acsr weasel conductor to aaac covered conductor from 33/11 kv substation kamaluaganja to 11kv mukhani under electricity distribution division (rural) haldwani.