Tender For tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables
Tender For special repair replacement of fire alarm and fire detection system alongwith connected works at certain otm accns provn of water purification plant capacity 1000 lph special repair replacement of lt feeder pillar box panel lt network distribution
Tender For mo(v)/cpro/n1/25vecc001 for procurement of gshb, beu, agds, rukmani and sirs spares - motor pinion 20t, roll bar (aft), relay 24v, 1a,3changeover, choke -tl (115v, 60hz), electrolytic capacitor 100 f 63 or 64 vdc, roll bar (forward), capacitor 3 m f/400v, translucet cover-2 (blue), translucet cover-1 (blue), dimmer choke drg.no.ga-19-215715-a3, push button red button, anti condensation heater 230v ac 500w, anti collision light lamp type a7079b-24, 28v,40w, anti collision light, synchro 18ct 4b, connector ms 3108e 31 7s/ms3108f, neon lamp 110v/115v, connector ms 3106 f36-10p, connector ms 3106 f32 7s, anti backlash gear 150t, gasket size 36 ms3102, translucent cover-1(blue), connector ms 3102r 36 10p, connector ms 3108 e36-10s/ms 3108 f36-10s, rotary switch 3 pole on/off, capacitor 1200 m f/250v, bar illumination select switch, power relay 24v,5amp 2changeover type mpc/24d, capacitor 170 m f/250v, ic 1524, indicating lamp holder with red lens type il-18, motor tacho gear head, power transistor 40410 2n6193, translucent cover-2(blue), power transistor 40411, diode type 1n 4007, ball bearing no.6007-2rz/2rs1(drg no.e-132-10596), connector ms 3102 r 32-10p, ic 555, retainer ring, diode 2sme, tantalum electrolytic capacitor, 100uf, 20v, connector ms 3106f-16s-4s, gasket size 32 ms 3102, diode, gasket size 16, gasket size 32, wired enclosure with one channel, hand held key gun key loader, analog addressable ionisation smoke detector with base, smoke detector tester, analog addressablemanualcallpoint, conventional ultraviolet flame detector, heat detector tester, 2 core 2.5 sq mm screened unarmored lfh cable, 2 core 2.5 sq mm screened cable, rj 11 connector, spectrum analyser, power analyser, 3 pin round shell recept.plug, 7 pin ms connectors ms3106f-16-1p gp c&c tb, central indicating assembly ca5427, audio alarm unit assembled mounted, radiation survey meter with 6v battery (portable) order no 3, contamination monitor with 6v battery (portable) order no 30, digital pocket dosimeter pm1203
Tender For supply of alarm monitoring system ams with software as per tts , control panel with 15 inch ams display and yard supplied equipment in switchboard room bulk head mounted as per tts , display of 12 or 15 inch flush mounted on bridge console display size will be confirmed during detail design as per tts , power supply to the displays is either from individual 230v ups or from common 24v dc ups as per design and tts , audio visual high intensity flashing beacon as per tts , i o cards digital analog digital counter rpm rtd serial link etc network switches etc as per design and tts , alarms printer as per tts , ups with batteries cum dc distribution board of suitable capacity refer clause 8.2 as per tts , addressable fire detection and general alarm system as per tts , combination detector smoke or heat or rate of rise temperature or uv-ir or optical with base and mountings as per tts , heat detector with base and mountings as per tts , flame detector with base and mountings as per tts , indoor manualcallpoints with mountings as per tts , outdoor manualcallpoints with mountings as per tts , general alarm push button with cover to avoid accidental activation with mountings as per tts , sensors or switches for monitoring door status open or close as per tts , bilge level float switches as per tts , high level float switches side mounted for fuel oil tanks as per tts , high level float switches top mounted for dirty oil tank as per tts , temperature transmitter as per tts , pressure transmitter as per tts , supporting accessories wt junction boxes cable connectors glands interface converters power supply converter with auto transfer switch galvanic isolators , special cables refer clause-11 as required as per tts , obs list of spares and qty as required as per tts , special tools and commissioning spares as required as per tts , class inspection charges as lumpsum , documentation drawings certificates installation operational and maintenance manuals as per tts , service support for training testing commissioning and trials as lumpsum , any other item not included above however the same would be required for proving the system during commissioning or hats or sats as required as per tts , man day rate for deputing service engineer beyond lump sum cost due to delay beyond control of supplier
Tender For supply of addressablemanualcallpoint (for safe area) , manualcallpoint - explosion proof and weather proof for hazardous areas , multi sensor detector , intrinsically safe rate of rise heat detectors for hazardous areas
Tender For supply of interior work etc c c -termination of 4c x 25 sq mm cuar xlpe cable , termination of 4c x 2. 5 sq mm cuar xlpe cable , termination of 16 sqmm copper flexible cable , termination of 25 sqmm copper flexible cable , 100 mm gi raceway , 150 mm gi raceway , 300 mm gi raceway , fabrications for cable tray support , 900mm linear suspended 15 watt led , 1200mm linear suspended 20 watt led , 8ft linear suspended 40 watt led , 120 degree axeon v connector , 120 degree axeon y connector , 1. 0m suspension for rcc ceiling , trim led tube light 4ft , trim led tube light 2ft , 2x2 led fitting 32 to 36 watt , down light fitting 12 to 15 watt led , recess mounted spot light 1 to 3 watt , led rope light 5 watt per meter , wall fan 16 inch , 250mm exhaust fan with louvers , ceiling fan sweep 1200mm , 80mm dia gi electrode 3 meter long , 8g gi wire , 10 sqmm copper flexible cable , 16 sqmm copper flexible cable , main lighting and power 12 way vtpn db , 8 way etpn db , 4 way etpn db , ups in out db 63 amps 4 pole , ip 66 enclosure for ac outdoor units , 4 pair cat 6 shielded computer cable , tag block 100 pair , tag block 20 pair , 50 pair armoured pvc cable , telephone outlet box with top plate , ip pbx system cloud based , standard phone , executive phone , ip phone , krone connector 60 pairs , cat 6 computer cable fr , rj45 computer jack cat6 modular , 42u rack with accessories , 12u rack with accessories , patch panel , network switch 24 port , patch cord 2 meter , patch cord 1 meter , existing smoke detector removing and installation , hdmi cable 15 meter , hdmi cable 20 meter , 4mp ip fixed rugged dome camera , 32 channel nvr with 4 sata , 24 port poe switch with 4 sfp ports , 32 inch flat screen hd led monitor , 4 tb surveillance hard disk , 12u network rack with accessories , 24 port loaded patch panel , 5 meter hdmi cable , 3 meter hdmi cable , 1 meter patch cord , pvc square junction box for cctv , media converter , 6 kva double conversion online ups , floor popup boxes 8 module , removing of old conduit , removing of old light point wiring , removing of old circuit wiring , removing of old switch sockets rj11 and rj45 , removing of cat 6 cable , removing and shifting of fire alarm panel and smoke detectors , removing of old 6 way or 8 way db , removing of 2x2 and linear light fixtures , installation and testing of old light fixtures , installation and testing of old power dbs , removing of old power cables , removing and shifting of old networking rack , 20 hp cooling only vrf unit , 4 tr round cassette unit , 0. 8 tr 1 way cassette unit wind free , 1. 0 tr 1 way cassette unit wind free , 1. 56 tr 1 way cassette unit wind free , 2. 0 tr 1 way cassette unit wind free , cordless remote controller , cordless remote controller for round cassette , y joints , t joints , installation of 20 hp outdoor unit , installation of 4 tr round cassette unit , installation of 0. 8 tr 1 way cassette unit wind free , installation of 1. 0 tr 1 way cassette unit wind free , installation of 1. 56 tr 1 way cassette unit wind free , installation of 2. 0 tr 1 way cassette unit wind free , copper piping with nitrile rubber insulation , main copper piping for outdoor to y joint , control and transmission cabling 2 core 1 sqmm , upvc insulated drain piping 25 mm , gi cable tray for copper piping and cables , refrigerant gas topping , lifting of units to site , ms stand for outdoor unit floor mounted , freight and transportation , drier filter , core cutting in rcc or wall , minor civil work for ac , nitrogen pressure testing and recommissioning 30 hp odu , dismantling and installation of round cassette unit 4 tr , old vrf copper //bid details2 / 111piping modification , old vrf control cabling modification , old vrf drain piping modification , old vrf gi cable tray work , old vrf gas topping , installation of split ac , dismantling of split ac , installation of cassette ac , dismantling of cassette ac , copper piping with insulation 1. 0 to 1. 5 tr , c