Tender For repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressablemanualcallpoint / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For corrigendum : addn altn to external services in tech area and provn of fire alarm centralized monitoring panel in fire section at afs tambaram
Tender For tender for supply of supplying , installing , testing and commissioning approved make microprocessor based single (01) loop , networkable addressable fire alarm control panel , supplying , installing , testing and commissioning approved make digital audio amplifier. , supplying , installing , testing and commissioning approved make remote paging station for zone selection , supplying , installing , testing and commissioning approved make modbus interface gateway , the mimic annunciator for the fire alarm control panels (facp). , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector , supplying , installing , testing and commissioning approved make addressablemanualcallpoint , supplying , installing , testing and commissioning approved make addressable control module for sounders , supplying , installing , testing and commissioning approved make addressable relay module for ahu , access control , lifts , staircase pressurization , fire suppression & other third party outputs , supplying , installing , testing and commissioning approved make isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement , supplying , installing , testing and commissioning approved make response indicator , supplying , installing , testing and commissioning of hooter cum strobe with in-built lithiumion battery , supplying , installing , testing and commissioning approved make 2w multi-tap wall mount speakers , supplying , installing , testing and commissioning of approved make auto dialer which supports gsm and pstn both , supply and laying of 2 c x 1.5 sq.mm. armoured cu multi-stranded twisted shielded frls copper cable , red in colour. , camc for 4 years after expiry of one year warranty of addressable fire detection system
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressablemanualcallpoint ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressablemanualcallpoint , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges
Tender For supply of addressable type fire alarm system at in north paravur : : - sitc of addressable main fire alarm panel , sitc of repeater panel , sitc of addressable photo thermal detector , sitc of addressablemanualcallpoint , sitc of addressable horn cum strobe , sitc of fault isolator , sitc of addressable fire control module , sitc of response indicator , supply and laying of 2x1.5 sqmm fire alarm armoured cable , sitc of mcp signage , sitc of relay module
Tender For supply of replacement of defective or senseless with compatible multi sensor smoke detector , xipe cross linked polythene thermostatic cable cable multi core , laying charges for cable including fire proof pipe , compatible addressablemanualcallpoint , compatible addressable sounder and strobe , online power backup source 1000va 60min 4 no 62 ah battery , addressable panel external surge supply with spd integration including 0.2 ohm rapid release surge cancellation device including wiring , installation and configuration , fire bell with manualcallpoint including installation and electrical socket with wiring , annual maintenance contract for existing infrastructure of afds for 03 panel and allied equipment
Tender For supply of iron safe 03 locker make-godrej or similar configuration safe deposit box / cabinet - for safe keeping of paper / cash / documents type an individually secured container for paper / cash / documents constructions double cabinet type ? cabinet inside cabinet comprising of an external cabinet and internal cabinet for body as well as door number of drawers n.a assembly of components by combination of bolting , welding and riveting or screwing elding by annual rate contract welding conforming to is 816/latest number of shelves 2 main locking arrangement no secondary locking no snap shut mechanism on door no annular sealing gasket between inner body and door n.a fire seal no key retention mechanism in drawers n.a sensor to detect attack on safe using tools (power hammer, power drill or similar) na alarm transmission from inside of safe (safe is in locked condition) n.a alarm transmission n.a minimum battery life n.a time bound health monitoring n.a encrypted communication between safe and alarm panel (at least aes-128 bit) n.a distance of alarm panel from safe n.a method to arm / disarm n.a alarm panel alerts for burglary attempt no alarm panel alerts for panel tempering no wireless sensor communication usinge unlicensed band carrier frequencies n.a number of telephone numbers that can be programmed to receive alarm alerts in the form ofvoice and / or sms n.a anti fishing mechanism for coin slot no snap shut mechanism for drawer no bolt detent mechanism for main door no material for internal cabinet steel material for external cabinet steel door material steel shelves material steel handle material zinc base alloy type of main lock 6 lever dual control type of secondary lock no secondary lock number of locks no lock depository drawer lock n.a inside height of safe 10mm 560 mm inside width of safe 10mm 362 mm m inside depth of safe 10mm 355 mm external height of safe 10mm 764 mm external width of safe 10mm 505 mm external depth of safe 10mm 540 mm inside height of top drawer n.a packing corrugated sheet packing marking n.a marking of key n.a surface finishing n.a warranty periods 1-year [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of refurbishment of room flooding system of server room at sauw ins satavahana c c -refilling of hfc 227ea gas 1,1,1,2,3,3,3 hepta fluro propane, zero odp, stored pressure, gas , conventional gas release panel with battery backup and cross zoning facility 2-zone with fire ext automatic mini intuitive fk-5-1-2 300gm ss sp red 79 c with nrv , ms container strap for mounting and fixing the agent containers to the wall , ul container strap for mounting and fixing the agent container to the wall , valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and a safety cap 25 bar , pressure gauge cum switch for monitoring the cylinder pressure 0-60 bar, 22. 50 bar switch point pressure switch wasco switch point 5bar 72. 5 psig imp with fire ext automatic wm fk 5-1-12 4kg , hydro static pressure test 50 bar, inverted baker test, helium leak detection test, epoxy powder painting, dismantling, commissioning charges , conventional optical smoke detector with double dust trap chamber design, optimized performance using internal algorithm, central led for 360 status visibility, compiles to en 54-7 standard , conventional rate of rise heat detector, heat alarm threshold temperature 58 c central led for 360 status visibility, complies to en 54-7 standard and approved by lpcb, vds , installation and delivery charges