Tender For supply of supply of 6 a sp mcb , supply of 10 a sp mcb , supply of 16 a sp mcb , supply of 20 a sp mcb , supply of 25 a sp mcb , supply of 32 a sp mcb , supply of 20 a dp mcb , supply of 20 a tp mcb , supply of 40 a fp mcb , supply of 63 a fp mcb , supply of 125a four pole fp mccb , supply of 200a four-pole fp mccb , supply of 40 a, double pole, rccb , supply of 63 a four pole mccb , supply of four pole, ac1 rating 40a , contactor , supply of three pole ac3, 32a rating contactor , supply of under current monitoring relay , supply of 3-pole power contactor with add on block , supply of thermal overload relay , supply of rotary operating direct handle for mccb , supply of rotary operating extended handle for mccb , supply of 06 way double door db , supply of weather proof frp junction box , supply of copper flexible cable 2c x 1.5 sq.mm , supply of copper flexible cable 3c x 1.5 sq.mm , supply of copper flexible cable 3c x 2.5 sq.mm , supply of 4 c x 10 sq.mm xlpe armoured aluminium cable , supply of frlsh single core copper conductor 1.5 sqmm , supply of frlsh single core copper conductor 2.5 sqmm , supply of frlsh single core copper conductor 4 sqmm , supply of frlsh single core copper conductor 6 sqmm , supply of heat shrink straight through joint kit for 3.5 core 95 sqmm , supply of 4 feet, 20w energy efficient led batten light fitting , supply of 9w led bulb with b22 base , supply of 20w led bulb with b22 base , supply of square type 36 w led down light , supply of 50 w led fllod light , supply of 70 w led street light , supply of 1200 mm sweep five star rated bldc fan , supply of 150 mm sweep exhaust fan , supply of 400mm sweep pedestal fan , supply of 300mm sweep wall fan , supply of 300 mm sweep table top type rechargeable fan , supply of 5 or 6 amp, 3 pin plug top , supply of 15 or 16 amp, 3 pin plug top , supply of automatic programmable analog time switch , supply of 3 phase digital multifunction meter , supply of flush-mounted analog panel type ammeter , supply of flush-mounted analog panel type voltmeter , supply of panel mounting red pilot light , supply of panel mounting green pilot light , supply of panel mounting yellow pilot light , supply of panel mountingf blue pilot light , supply of panel mounting amber pilot light , supply of connector din rail mounted for 2.5 sq. mm conductors , supply of connector din rail mounted for 25 sq. mm conductors , supply of mild steel din rail 1 mtr length , supply of 20w, 4 feet led tube light , supply of surface mountable, 15w led emergency lamp , supply of 1hp centrifugal pump single phase , supply of digital vernier caliper , supply of addressable photoelectric smoke detector for fire alarm system , supply of addressable zone interface module , supply of audio visual alarm device for addressable fire alarm system , supply of manualcallpoint mcp for addressable fire alarm system , supply of 2 core 1.5 sqmm red fire alarm cable //bid details 2 / 53
Tender For repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressablemanualcallpoint / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and directed., supply
Tender For supply of loop card for fire alarm control panel , monitor module addressable type monitor module. , control relay module addressable control relay module. , optical cum thermal detector intelligent addressable multi criteria optical cum thermal detector wit , optical cum chemical detector intelligent addressable type, maintenance easy optical cum chemical de , response indicator , break glass type manualcallpoint intelligent addressable break glass type manualcallpoint. , sounder or hooter addressable type loop powered /external powered sounder or hooter with multiple to
Tender For tender for supply of supplying , installing , testing and commissioning approved make microprocessor based single (01) loop , networkable addressable fire alarm control panel , supplying , installing , testing and commissioning approved make digital audio amplifier. , supplying , installing , testing and commissioning approved make remote paging station for zone selection , supplying , installing , testing and commissioning approved make modbus interface gateway , the mimic annunciator for the fire alarm control panels (facp). , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector , supplying , installing , testing and commissioning approved make addressablemanualcallpoint , supplying , installing , testing and commissioning approved make addressable control module for sounders , supplying , installing , testing and commissioning approved make addressable relay module for ahu , access control , lifts , staircase pressurization , fire suppression & other third party outputs , supplying , installing , testing and commissioning approved make isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement , supplying , installing , testing and commissioning approved make response indicator , supplying , installing , testing and commissioning of hooter cum strobe with in-built lithiumion battery , supplying , installing , testing and commissioning approved make 2w multi-tap wall mount speakers , supplying , installing , testing and commissioning of approved make auto dialer which supports gsm and pstn both , supply and laying of 2 c x 1.5 sq.mm. armoured cu multi-stranded twisted shielded frls copper cable , red in colour. , camc for 4 years after expiry of one year warranty of addressable fire detection system
Tender For supply of apollo make addressable type xp-95 optical detector as per attached specifications , apollo make addressable soteria multi-sensor detector as per attached spec , apollo make addressable xp-95 heat detector as per attached spec , apollo make addressable xp-95 manualcallpoint as per attached spec , apollo make addressable xp-95 intrinsically safe optical detector as per attached spec , apollo make series 65 conventional optical smoke detector as per attached spec
Tender For bid to ras bid to ras supply of rrc for addressable fire detection system onboard in ships and yard crafts at nsry karwar -repairs to main control panel , repairs to repeater panel , repairs to control cards , repairs to ionization smoke detector , repairs to multi sensors , repairs to temperature heat detection sensor , repairs to flame detector , repairs to manualcallpoint , repairs to front panel switches , repairs to alarm bells lights hooters , repairs to internal circuit wiring , repairs refurbishment of ups , repairs to cabling from main control panel , reprogramming of the pcbs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressablemanualcallpoint ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi
Tender For supply of fire alarm detection system - addressable fire alarm panel-02 loops with lcd , addressable smoke detector with base , addressable heat detector with base , addressablemanualcallpoint , addressable or conventional hooter cum strobe , addressable control modules , addressable input or output module , addressable input module , response indicator , addressable loop isolator , installation charges