Get complete information related to latest Ahu Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ahu Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ahu Panel Repair Tenders.
Tender For corrigendum : repair/ replacement of pump control panel, pump, motors, earthing, copper cable, aviation lightening, water level indicators and allied works at various locations under age e/m no ii of ge (utility) secunderabad
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - 285 instrument erection contract for revamping of flow lab at instrument workshop at rcf trombay unit; as per sow; as per sow- 1 fabrication, erection & installation of cable tray 50 mm width with necessary support m s angle 50 mm. this job includes two coat of primer and two coat of anticorrasiveepoxy coats. supply of primer and paint to be included and fabrication, erection and installation of cable tray. 50 mtr, 2 supply and installation side mounted glass tube level indicator approx 2.5 mtr length with high and low level switch adjustable over the full length. 1 no, 3 supply and installation and commissioning of centrifugal pump flow capacity of 30 m3/hr head 45 meter suitable for vfd drive 1 no, 4 magnetic flow meter 0 to 50 m3 /hr, 4" size flanged 150# rf, accuracy 0.1% with calibration certificate 1 no, 5 4" size ss material, 150#, flanged on/off valves with actuator, limit switch indication dome, solenoid valve 4 no, 6 vfd with panel and start /stop pb, and speed control 1 no, 7 pressure gauges 1 no, 8 supply, installation of piping suitable for the flow skid in sizes 4" and as per requirement 1 lot, 9 flow totalizer with contacts and set rest function 1 no, 10 panel for skid operation with pb, lamps, selector switch 1 no, 11 supply, installation of pvc coated cu tubing with necessary fittings for 4 valves 80 mtr, 12 supply, installation of air distribution header 6 points stainless steel 1 no, 13 supply, installation of 50 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 14 supply, installation of 100 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 15 supply, installation of layingof signal and power cables 300 mtr., 16 1 pair x 1.5 mm2 signal cable 300 mtr., 17 power cable for motor existing cable to be reused as per requirement 500 mtr, 18 spool pieces with one end flanged connection and other end with triclover coupling in ss304 of various sizes as below with 10d and 5d lengths. set of spool pieces shall iclude following sizes: 6", 4", 3", 2.5", 2", 1.5", 1", 3/4", 1/2" each in quantity 2 numbers 1 lot removal jobs 1 structural steel which includes ms ladder tray, stantion, alluminium cable trays 300 kg, 2 cable- signal , power cable removal 100 mtr., 3 level indicator 2 no, 4 existing piping and fittings 1 lot, 5 removal of existing pipe and fittings 1 lot
Tender For repair /calibration of fixed dd fire pump sea water discharge flow meter view non ops , repair /calibration of 37 tph portable dd fire pump discharge flow meters view defective , repair/overhauling of chilled water balancing flowmeter view leakage , serviceability checks/ calibration of main fuel flowmeter control panel in mcr view erratic and malf
Tender For repair/ replacement of pump control panel, pump motors, earthings, copper cable, aviation lighting, water level indicator and miscellaneous repairs to electric supply system, capacitor panel, high mast, amf panel and allied works at grph, mceme, depo
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous