Get complete information related to latest Air Break Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Break Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Break Contactor Tenders.
Tender For supply of compressor zr54 kce-tfd-522 , condensor fan 550 mm , evaporator fan , liquid receiver fkr- 59 , thermal expansion valve aaae- 4 , filter dryer ekim , air filters 625 x 400 x 50 mm , air filters 500 x 400 x 50 mm , condensor valves , compressor zr72 kce-tfd-52e , condensor fan 5 lobe 630 mm , thermal expansion valve aaae- 5 , filter dryer , ss steam pipe , rubber steam hose , air filter 592 x 592 x 50 mm , air filter 592 x 370 x 50 mm , hp switch open , lp switch open , mcb 2-pole, 240vac, 10a , mcb 3- pole, 240vac, 16a , mcb 1-pole, 240vac, 10a , mcb 4-pole, 240vac, 63a , airbreakcontactor , phase failure relay , control transformer , blower motor , dehumidification , humidifier cylinder with 3 electrodes 5 , heater thermostat , heater 1.5 kw , temp _ rh sensor , condensor fan 630 mm 1phase , microprocessor with preloaded program
Tender For bid to ras tender for supply of mpcb and mcb - motor protection circuit breaker asper iec 947 having magnetic thermal release with 1no aux contact range 2.5 - 4 amps make siemens or schnider , motor protection circuit breaker asper iec 947 having magnetic thermal release with 1no aux contact range 0.25 - 0.4 amps make siemens or schnider , motor protection circuit breaker 10-16 amps 3pole over load range 10 -16 amps 1n0 make siemens or schnider , airbreakcontactor ac3 duty 4kw dol minimum current rating 9a aux.contacts 2no+2nc coil voltage 220v 50/60 hz along with suitable coil suppressor make siemens or schnider , airbreakcontactor ac3 duty 5.5kw dol minimum current rating 12amps aux contacts 2no + 2nc coil voltage 220v 50/60 hz make siemens or schnider , airbreakcontactor ac3 duty 4kw dol minimum current rating 9 a aux contact 1no coil voltage 220v 50/60 hz along with suitable coil suppressor make siemens or schnider , miniature circuit breaker as per is 8828 1966 iec 898 c type 1amp sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker asper is8828-1996 iec 898 c type 2amps sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker as per is 8228 1996 iec 898 c type 6amps sp breaking capacity 10 ka make siemens or schnider , miniature circuit breaker as per is8828 1996 iec 898 type c 4 amps dp breaking cap 10ka make siemens or schnider , miniature circuit breaker , asper is8828 1996 iec 898 c type 6 amps dp breaking capacity 10 ka make siemens or schnider