Get complete information related to latest Air Break Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Break Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Break Tenders.
Tender For corrigendum : supply of sitc 160kva od transformer te bongaigaon -sitc 160kva od transformer te bongaigaon : -supplying of out door type 160 kva step down transformer , itc of the above transformer , providing and laying in position cement concrete foundation , supplying and erection of three piece nonlinear resistor type lightning arrestor , providing and fixing 11kv triple pole post gang operated airbreak switch , supplying and fixing 11 kv do fuse , providing and fixing ht danger notice plate , providing and fixing mv danger notice plate , earthing with gi earth plate , providing and fixing loop earthing in gi pipe , providing and fixing loop earthing , earthing with gi earth pipe , providing and laying earth connection , loop earthing , supplying of steel armoured aluminum conductor ug power cable , laying and fixing of power cable on wall surface , supplying and making end termination , repairing and painting the entire dp , making inter connection . , supplying and fixing , dismantling of existing transformers , providing fabricating and fixing iron fencing or railing on boundary wall or ground for sub station area
Tender For supply of kva , synthetic enamel paint sand colour make-asian, berger , synthetic enamel paint olive green-colour makeasian,berger , synthetic enamel paint dark brown colour make-asian,berger , synthetic enamel paint black colour make-asian,berger , cfl 10w oblique led 12w for fd tech shelter re-locatable jfcp , led bulb 18 watt for fd tech shelter re-locatable jfcp , mcb 32 amp db for fd tech shelter re-locatable jfcp , 15 amp switch for fd tech shelter re-locatable jfcp , 16 amp socket for fd tech shelter re-locatable jfcp , led bulb 05 watt for fd tech shelter re-locatable jfcp , vaccum cleaner for fd tech shelter re-locatable jfcp , mcb 16 oblique 32 amp for fd tech shelter re-locatable jfcp , 5 amp modular switch and socket for fd tech shelter re-locatable jfcp , 15 amp modular switch and socket for fd tech shelter re-locatable jfcp , ceiling fan for fd tech shelter re-locatable jfcp , synthetic enalmel paint olice green-colour makeasian,berger for fd tech shelter re-locatable jfcp , synthetic enamel paint dark brown colour makeasian,berger for fd tech shelter re-locatable jfcp , synthetic enamel paint black colour make-asian,berger for fd tech shelter re-locatable jfcp , synthetic enamel paint sand colour make-asian, berger for fd tech shelter relocatable jfcp , ro chemical ro scaled guard, 5020 ro antiscalent for ro plant 5000 lpd , ro wessel for ro plant 5000 lpd , sand carbon for ro plant 5000 lpd , corel sand for ro plant 5000 lpd , ro membrance pc 250 lph for ro plant 5000 lpd , pp spun filter for ro plant 5000 lpd , serviceable cable 2 sqmm 4 core for generator set 1. 4 kva , flexible wire for generator set 1. 4 kva , fuel filter for generator set 1. 4 kva , oil filter for generator set 1. 4 kva , engine oil 20w for generator set 1. 4 kva , fan belt for generator set 25 kva , benjo bolt 19 mm for generator set 25 kva , fuel tank cap for generator set 25 kva , fuel filter for generator set 15 kva kg 164j , oil filter for generator set 15 kva kg 164j , fuel fipe line for generator set 15 kva kg 164j , fan belt for generator set 15 kva kg 164j , benjo bolt for generator set 15 kva kg 164j , fan belt for generator set 63 kva , oil filter for generator set 63 kva , air filter for generator set 63 kva , fuel filter for generator set 63 kva , fuel pipe for generator set 63 kva , over flow pipe for generator set 63 kva , mcb 63 amp 3 phase for generator set 63 kva , change over switch 63 amp for generator set 63 kva , fuel pipe for generator set 30 kva , led ceiling light 10w for generator set 30 kva , sand bag for generator set 30 kva , cfl 11w for generator set 30 kva , 5 amp modular switch and socket for generator set 30 kva , exhaust fan for generator set 30 kva , hdpe water cover 12 feet x 12 feet 250 macron for fd toilet mob toilet , hdpe water cover 30 feet x 20 feet 250 marcon for fd toilet mob toilet , hdpe water cover 30 feet x 30 feet 250 macron for fd toilet mob toilet , cable 6 sqmm 2 core each roll 90m for fd toilet mob toilet , service cable for fd toilet mob toilet , mcb 15 amp for fd toilet mob toilet , mcb 32 amp for fd toilet mob toilet , oil filter dhpp for fd toilet mob toilet , engine oil filter for fd toilet mob toilet , fuel pipe for fd toilet mob toilet , fan belt for fd toilet mob toilet , evr for fd toilet mob toilet , fuel pipe long for generator set 7. 5 kva , fan belt alternator 45 no for generator set 7. 5 kva , silencer muffler assy for generator set 7. 5 kva , mcb 100 amp for generator set 7. 5 kva , door hinge for generator set 7. 5 kva , tread tape for generator set 7. 5 kva , bty terminal lead for generator set 7. 5 kva , vaccum cleaner for //bid details2 / 125generator set 7. 5 kva , led ceiling light 10w , 5 amp switch , 5 amp socket , 15 amp socket , paint white colour , paint red , vinyl oblique laminate flooring , sand bags , ac stablizer , maint of ac and gas filling , exhaust fan 450mm for fd toilet , flash sys of fd toilet for fd toilet , tap for fd toilet , led tube light for fd
Tender For tender for supply of 3 pole airbreak power contactor d d -3 pole airbreak power contact -tor ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 24v dc , aux. contacts 2no+2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 08-10 amp. at 415v , 50hz , with coil voltage 415vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 24v dc , aux. contacts 2no+2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 110vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 11-13 amp. at 415v , 50hz , with coil voltage 415vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 110vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 15-18 amp. at 415v , 50hz , with coil voltage 415vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 22-26 amp. at 415v , 50hz , with coil voltage 24v ac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact -or ac-3 category , 22-26 amp. at 415v , 50hz , with coil voltage 110vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting , confirming to is/iec60947-4-1 , 3 pole airbreak power contact tor ac-3 category , 22-26 amp. at 415v , 50hz , with coil voltage 220vac 50hz , aux. contacts 2no+ 2nc , screw terminal , standard 35 mm din rail snap fit mounting & base mounting ,
Tender For tender for supply of 7 8 vibration eliminator (oil inlet to comp) , drier ( 2 core 1 5 by8 od) , 1 5 8 vibration element comp suction , 80nb chilled water pump suction bellow , 80nb chilled water pump discrarge bellow , crank shaft , connecting rod with piston , main rotor , valve plate complete , bearing bush , small end bearing , thrust washer , thrust washer , oil flow switch , oil flow switch complete , discharge shut off valve complete , suction shut off valve complete , oil filter , filter with o ring , compressor oil filter including o-ring , integrated check valve complete , o ring for filter element , gasket set , set of gaskets , shaft seal , shaft seal , compression ring , compression ring , oil scrapper ring , piston pin , set of bearings , airbreak contactor 2no 2no aux contact 240v 16amps , airbreak contactor , airbreak contactor , disc hose 65mm a c chill water pump , disc hose 125mm a/c sea water pump , suction hose 150mm a/c sea water pump , mushroom flaps for systems he 1 he 2 he 3 s5s he 18 , mushroom flaps for systems s1s s2e s6e ns , mushroom flaps for systems s21e , mushroom flaps for systems s3s , mushroom flaps for systems s4e , cooling thermosat (danfoss) , socket head screw 1 lot 100 nos , socket head screw 1 lot 100 , socket head screw 1 lot 100 , socket head screw 1 lot 100 , electronic timer 0-60sec with 220v 50z opertaing coil , four pole mcb rated 16 amps mds make , hrc fuse 32a make ee gec , vibration eliminator size 2 5 by 8
Tender For annual rate contract for work of supply and fixing of various electric spare parts for starter and panel ci specials sluice valve nrvs of various uwss city sardarshahar under phed div sardarshahar - 261400 supply and fixing of oil / airbreak dol / star delta starter made out of sheet steel powder coated enclosure with single phasing protection, on / off push buttons, etc. complete in all respect suitable for following rating motors.261420 fully automatic star/ delta starter261424 30.0 hp to 35.0 hp, 261400 supply and fixing of oil / airbreak dol / star delta starter made out of sheet steel powder coated enclosure with single phasing protection, on / off push buttons, etc. complete in all respect suitable for following rating motors. fully automatic star/ delta starter261423 20.0 hp to 25.0 hp, 100700 p&f 240/415 v porcelain kitkat fuse (/hbc type) conforming to is:2086,1983 0n existing board/ sheet including making connections with lugs, testing etc. as required100706 100 a ,415 v100706.2 group - 1, 080300 sf of (0-500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.080301 analog type ( 96 mm x 96 mm )080301.2 group - 1, 080400 sf of ct operated direct reading type ampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.080410 analog type ( 96 mm x 96 mm )080411 below 500 a080411.2 group - 1, 080600 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc. as required .080600.2 group - 1, 080800 sf of 110/220 v, led (22.5 mm dia ) indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 blue colour080802.2 group - 1, 081400 p & f cam operated rotary switches on existing panel with 2 way and off position081410 one pole081412 32 a081412.2 group - 1, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081513 32 amp.081513.2 group - 1, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081513 32 amp.081513.3 group - 2, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081516 70 amp081516.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 amp081702.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 amp081703.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 amp081704.2 group - 1, 082000 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 amperes including making connection, programming etc. as required082002 one day & week reserve (mechanical type )082002.2 group - 1, 090600 sitc of quick make and q