Tender For repair of glsr sump next to the office, construction of platform and drain and installation of compressor mission to clean the vehicles of the health branch of the municipality office
Tender For providing of repair and overhauling service - repair of water bath shaker compressor; mac water bath shaker msw 27501 (sl); yes; buyer premises
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; contract for inspection, repair & high speed dynamic balancing of lp turbine rotor of synthesis gas compressor unit in ammonia plant at rcf thal; buyer
Tender For supply of repair of radiator of mg , ac gas refiling mg , repair of ac compressor of als amb , ac gas refiling als med amb , repair of ac switch of als amb
Tender For bid to ras corrigendum : providing of repair and overhauling service - repair of elgi aircompressor ts07hn; elgi horizon aircompressor; yes; buyer premises, service provider premises
Tender For providing of repair and overhauling service - stand for polishing compressor turbine blade; stand for polishing compressor turbine blade; yes; buyer premises
Tender For repair and overhauling service - kg5h 230 kpcl; kg5h 230 kpcl; yes; buyer premises, service provider premises-detailed defects: (a) fuel level indicator qty-01 u/s, needs to be replaced. (b) 1st stage (3.7 kg/cm2) qty-02 and 5th stage (264 kg/cm2) safety valve qty02 u/s, needs to be replaced. (c) hooter qty-01 and fire extinguisher qty-02 u/s. (d) charging alternator qty-01 and starter motor qty-01 u/s, needs to be repaired. compressor dip stick qty-01 broken, needs to be replaced. (e) pressure gauges (0-7 kg/cm , 0-21 kg/cm , 0-70 kg/cm , 0-16 kg/cm , 0-400 kg/cm ,0-600 kg/cm ,0-150 kg/cm ,0-150 kg/cm ,0-15 kg/cm ,0-15 kg/cm ) total qty-10 u/s, needs to be replaced. (f) drainage pipelines of dampner qty-06 and purge bottles qty-06 blocked, needs to be replaced. (g) pneumatic door struts qty-20 u/s and door hinges qty-12 broken, needs to be replaced. (h) delivery valve (0-400 kg/cm2) qty-04 and vent valve (0-400 kg/cm2) qty-04 u/s, needs to be replaced. engine solenoid 24v qty-02 and rmp meter qty-01 u/s, needs to be replaced. mechanical jack qty-04 u/s, needs to be repaired. (k) dew point meter qty-01 u/s to be repaired and calibrated. door lock qty-06 u/s, needs to be replaced. (1) charging adopter damaged qty-06 u/s, needs to be replaced. (m) search light qty-04 and panel light qty-06 u/s, needs to be replaced. (n) pre filter differential gauge qty-01 (range 0-1.5 kg/cm2) u/s, needs to be replaced (o) charging alternator, mechanical lubricator and radiator fan belt (qty-03) teared off, needs to be replaced. (p) silica gel of both dryer units saturated and needs to be replaced. pre filter, oil filter and after filter element (total qty-03) to be replaced. (q) air filter, fuel and oil filter element (total qty-03) to be changed..
Tender For corrigendum : supply of proc of mt spares f f - major kit clutch master cyl repair kit , assy cable complete , solenoid switch , belt v ribbed , gear lever kit , repair kit compressor , repair kit for spring brack chamber , repair kit frt spring brake actuator