Tender For construction of sub centre bhogoga district kathua (electrical part). - wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, with modular switch, modular plate, suitable gi box earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required (group-a), wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required., 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire, 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, 2 x 16 sq. mm + 1 x 6 sq. mm earth wire, 4 x 6 sq. mm + 2 x 6 sq. mm earth wire, 4 x 10 sq. mm + 2 x 6 sq. mm earth wire, 4 x 16 sq. mm + 2 x 6 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor single core cable in the existing surface/recessed steel/pvc conduit as required., 1 x 1.5 sq. mm, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 25 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 3 pin 5/6 a socket outlet, 15/16 a switch, 6 pin 15/16 a socket outlet, supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required, supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 a modular socket outlet and 2 nos. 5/6 a modular switch, connections etc. as required. (for light plugs to be used in non residential buildings)., supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, "c"curve including connections, painting etc. as required., supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required., 1 or 2 module (75mm x 75mm), 3 module (100mm x 75mm), 4 module (125mm x 75mm), 6 module (200mm x 75mm), 8 module (125mm x125mm), 12 module ( 200mm x 150mm), supplying & fixing of following way single pole and netural, sheet steel, mcb distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required., 6 way (double door), 16 way (double door), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/ rccb /isolator), 6 way ( 4+18), (double door), 8 way (4+24), (double door), supplying and fixing following rating, 240/415 v, 10 ka, "c" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required., single pole 6/10/16/32 amp, single pole and neutral 32 amp, single pole and neutral 63 amp,
Tender For supply of various types of electrical materials - insulation tape roll (6 meter), steelgrip, nippon, anchor, supplying miniature circuitbreaker of single pole breaker (confirming to is:8828) of 32 a c series) (note:- make with the lowest rate will be approved), havells, datar, legrand, c&s electric, supplying miniature circuitbreaker of single pole breaker (confirming to is:8828) of 32 a b series) (note:- make with the lowest rate will be approved), havells, datar, legrand, c&s electric, supplying of four pole isolators / only switch version of miniature circuitbreaker of 63 amps. (note:- make with the lowest rate will be approved), havells, datar, legrand, c&s electric, supplying electronic ding dong type call bell with heavy duty coil suitable to operate on 230 v a.c. & d.c. (note:- make with the lowest rate will be approved), anchor, leader, c&s electric, havells, modular switch 6 amp 1 module (for existing maintenance replacement), anchor rider, anchor penta, modular plug 5 pin 6 amp (for existing maintenance replacement), anchor rider, anchor penta, modular switch 16 amp 1 module (for existing maintenance replacement), anchor rider, anchor penta, modular plug 6 pin 16 amp (for existing maintenance replacement), anchor rider, anchor penta, compact led 18w tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated hf electronic driver complete. (note:- make with the lowest rate will be approved), philips, bajaj, crompton, four pole mcb c 63 amp. (note:- make with the lowest rate will be approved), havells, datar, legrand, triple pole mcb c 32 amp. (note:- make with the lowest rate will be approved), havells, datar, legrand, double pole mcb c 32 amp. (note:- make with the lowest rate will be approved), havells, datar, legrand, four pole isolators 100 amp. (note:- make with the lowest rate will be approved), havells, datar, legrand, double pole isolators 40 amp. (note:- make with the lowest rate will be approved), havells, datar, legrand, industrial plug original 1.25 mm crca sheet metal enclosureswith 20a. 2 pin plug & earth socket and 20a. 3 pin plug top with20a/30a single pole mcb complete erected on angle iron/ g.i. frame (note:- make with the lowest rate will be approved), havells, datar, legrand, copper cable 2 core wire 0.5 sqmm 90 meter (note:- make with the lowest rate will be approved), finolex, rr kabel, polycab, square led panel light 18 to 20 w. (slim edge-lit) provision for plain front frame with translucent cover fix to the housing complete. (note:- make with the lowest rate will be approved), philips, bajaj, crompton, led square / circular 9 to 12w down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete (note:- make with the lowest rate will be approved), philips, bajaj, crompton, led street light fitting suitable for above 40w to 48w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete (note:- make with the lowest rate will be approved), philips, bajaj, crompton, devalite, supplying ready to use retrofit t8 led 18 / 20 tube light with polycarbonate body, heat sink, integrated hf electronic driver complete & compatible to t8 / t12 led luminaire by disconnecting starter & ballast if necessary (for existing maintenance replacement), crompton, supplying decorative pre-wired box type fitting/batten suitable for 4 feet, t8 led tube light (excluding tube light). (for existing maintenance replacement), crompton, 3 pole mccb of 400a, 415v capacity with short circuit rating 36 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides (note:- make with the lowest rate will be approved), datar,
Tender For supply and installation of electric material of isi mark in the jurisdiction of jda division no.ii. - led tube light fitting complete 18 watt. 4, led tube light fitting complete 28 watt. 4, ignitior 70 - 400 watt for sodium light, electronic chokes for 36 watt fittings 4 long, led tube light 36 watt 4 complete fitting, starter for tube light, capacitor 10 m.f. for s.v. fittings, capacitor 4 m.f. for coolers, capacitor 3.25 m.f. for c. fan, capacitor 3.5 m.f. for e.fan, capacitor 2.25 m.f. for w.fan, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. socket 5/6 amp piano type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required switch 5/6 amp piano type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. socket 5/6 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. switch 5/6 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. socket 15/16 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. switch 15/16 amp modular type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. socket 15 amp piano type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. switch 15 amp piano type, combine 15 amps switch & socket with gang box, led blub 5 watts., led blub 9 watts, led blub 15 watts, led blub 20 watts, led blub 40 watts, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. m.c.b. 240/415 volt s/pole 6-32 amps, supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. m.c.b. 240/415 volt s/pole 40 amps, s.p.n. 40 amps 240 volts., supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections,testing and commissioning etc. as required. s.p.n. 63 amps 240 volts., supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. t.p.n.. 25 amps 415 volts., supplying and fixing following rating, four pole, (three phaseal), 415 volts, residual current circuitbreaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required t.p.n.. 40 amps 415 volts., supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. t.p.n.. 63 amps 415 volts., m.c.c.b. (4 poles) 63 amps 35k, m.c.c.b. (4 poles) 100 amps 35k, m.c.c.b. (4 poles) 200 amps 35k, m.c.c.b. (4 poles) 250 amps 35k, m.c.c.b. (4 poles) 400 amps 35k, m.c.c.b. (4 poles) 630 amps 50k, m.c.c.b. (4 poles) 800 amps 50k, industrial socket for 240 volts, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recess
Tender For supply and installation of electric material of isi mark in the installation under the jurisdiction of jda division i rhc jammu - led tube light fitting complete 18 watt. 4, led tube light fitting complete 28 watt. 4, ignitior 70 - 400 watt for sodium light, electronic chokes for 36 watt fittings 4 long, led tube light 36 watt 4 complete fitting, starter for tube light, capacitor 10 m.f. for s.v. fittings, capacitor 4 m.f. for coolers, capacitor 3.25 m.f. for c. fan, capacitor 3.5 m.f. for e.fan, capacitor 2.25 m.f. for w.fan, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. socket 5/6 amp piano type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required switch 5/6 amp piano type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. socket 5/6 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. switch 5/6 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. socket 15/16 amp modular type, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. switch 15/16 amp modular type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. socket 15 amp piano type, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. switch 15 amp piano type, combine 15 amps switch & socket with gang box, led blub 5 watts., led blub 9 watts, led blub 15 watts, led blub 20 watts, led blub 40 watts, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. m.c.b. 240/415 volt s/pole 6-32 amps, supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. m.c.b. 240/415 volt s/pole 40 amps, s.p.n. 40 amps 240 volts., supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections,testing and commissioning etc. as required. s.p.n. 63 amps 240 volts., supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. t.p.n.. 25 amps 415 volts., supplying and fixing following rating, four pole, (three phaseal), 415 volts, residual current circuitbreaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required t.p.n.. 40 amps 415 volts., supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. t.p.n.. 63 amps 415 volts., m.c.c.b. (4 poles) 63 amps 35k, m.c.c.b. (4 poles) 100 amps 35k, m.c.c.b. (4 poles) 200 amps 35k, m.c.c.b. (4 poles) 250 amps 35k, m.c.c.b. (4 poles) 400 amps 35k, m.c.c.b. (4 poles) 630 amps 50k, m.c.c.b. (4 poles) 800 amps 50k, industrial socket for 240 volts, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in
Tender For supply of fine filter of size 600mm into 600mm into 150mm , pnumatic solenoid valve 100 nb with air pipe make rotex or trident and aira , ac induction tubular heater 9 kw 415 volts 3 phase of length 1 point 5 m with ms powder coated terminal cover as per sample make as per sample , ac heating elements 6 kw 415 volts 3 phase of length 610 mm complete fitting as per existing location all as specified make telelec or escorts and theeta , contactor lc1f4004 make schinder , contactor lc1f3304 make schinder , circuitbreaker 280 oblique 400 a 4 pole cvs 400 f make schinder , circuitbreaker 112 oblique 160 a 4 pole cvs 160 b make schinder , cooper wire 2 point 5 sqmm 3 core , mccb 160a 3 pole 25 ka make l and t or seimens and legrand , shrounded copper conductor busbar 160 amp w type with pvc sleeves r dsl single bar , shrounded copper conductor busbar 200 amp w type with pvc sleevesy dsl single bar , shrounded copper conductor busbar 200 amp w type with pvc sleevesb dsl single bar , shrounded copper conductor busbar 200 amp w type with pvc sleeves e dsl single bar , cooper wire 4 sqmm 3 core make kei and havells , lift cabin cross flow 45w 220 v 50 hz , xlpe ug cable 16 sqmm 4 core make kei or polycab and plazza , xlpe ug cable 95 sqmm 4 core make kei or polycab and plazza , pvc insulated flexible flat copper conductor of size 0 point 5 sqmm 24 core , cabin fan 300 mm sweep make bajaj or havells and cg , automative battery 12v 12 ah make exide and amron , automative battery 12v 18 ah make exide and amron , exhaust fan 300 mm sweep make cg or khaitan and bajaj , xlpe ug cable 70 sqmm 4 core make kei or polycab and kaliga premium , phase sequence corrector 15 hp capacity with double contractor system make volina or univercell and marco , led bulk head light fitting 10 watts make havells or phillips and wipro , single phase 2hp sewage dewatering pump make kirloskar oblique crompton , line interactive ups with avr (v2) (q2) , molded case circuitbreakers (mccb) as per is / iec 60947 (q3)