Tender For supply of railway carriage fan 225 mm sweep, wall bracket type, 110 v dc fan to type - v of icf annexure 1, cs-3 to is:6680-92 with rdso annexure-h dec-2005. note: sl. no. 21 in t ype - v of the above mentioned icf annexure -1,to be read as follows [ warranty period: 30 months after the date of delivery ]
Tender For supply of heavy duty bldc air circulator fan 600mm sweep (24inch) wall mounting type suitable to work on 230v, 50hz, ac supply with speed regulator, power consumption at speed 1:100watts, power consu mption at speed 3:170watts, rated speed :1400rpm, air delivery :717cmm with reverse polarity protection, over voltage protection, short circuit protection, blocked blade protection confirming to is-2997/1994 with two years wa rranty. make: atomberg, orient, usha, crompton . [ warranty period: 24 months after the date of delivery ]
Tender For repair replacement maintenance to internal electrification with allied works, replacement of conventional light fittings to led fittings and repairs of ceiling fans, exhaust fan pedestal fan wall fan etc at rci technical area zone-i under ge i rnd rc
Tender For repair replacement maintenance of internal wiring with allied works replacement of conventional light fittings to led lights and repair of ceiling fans exhaust fan pedestal fan wall fan etc at rci residential area elsec cpdc dsc and etc under ge i rn
Tender For rc for call basis repairs and misc works of split ac in various bas of ec mumbai - attending complaint and wet servicing of ac unit upto 50 kms , attending complaint and wet servicing of ac unit upto 51 to 100 kms , attending complaint and wet servicing of ac unit above 101 kms , replacement of starting capacitor 80 to 100 mfd of ac unit , replacement of running capacitor 36 to 50 mfd of ac unit , replacement of capacitor for condenser fan 4 to 6 mfd of ac unit , replacement of sensor for split ac unit , replacement of contactor relay for split ac outdoor unit , replacement of starting relay of ac unit , replacement of thermostat of ac unit , replacement of selector switch of ac unit , replacement of blade for condensor of window or split ac unit , replacement of blower assembly for split ac unit without motor , replacement of pcb for conventional split ac indoor unit of 1.5 tr , replacement of pcb for outdoor unit of invertor type split ac , replacement of pcb for indoor unit of invertor type split ac , replacement of 1.5tr or 2tr split ac remote , replacement of fan motor for condenser unit of conventional 1.5 or 2 tr of ac , replacement of blower motor for indoor unit of 1.5tr or 2 tr of split ac , replacement of 20mm dia flexible pvc pipe for drain water connection of ac , charging of r22 or r32 or r134 or r410 refrigerant gas upto the optimum working pressure suitable for 1.5 or 2tr ac alongwith attending leakage , replacement of cond coil manufactured with cu tube and al fins with antirust coating and blue fin hydrophilic coating for sac incl. credit of old coil , dismantling of window ac unit alongwith casing ms supporting frame , dismantling of split or high sensible ac incl. id and od unit aw all acc. pump down of gas and keeping all dismantled material at safe location , transportation of dismantled 2 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units upto 20 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 21 km to 50 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 2 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 51 km to 100 km with all accessories incl. hiring of vehicle, manpower etc , transportation of dismantled 3no. to 5 no. ac units from 100 km upto 200 km with all accessories incl. hiring of vehicle, manpower etc , itc of 1.5 or 2tr window ac unit with properly finshing and minor civil work , itc of wall mounting type 1.5 or 2tr split ac unit with properly finishing and minor civil work , itc of 2x1.5 tr high sensible ac unit with properly finishing and minor civil work , s and f of 1 by 4 inch copper refrigeration pipe , s and f of 3 by 8 inch copper refrigeration pipe , s and f of 1 by 2 inch copper refrigeration pipe , s and f of 5 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 4 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 3 by 8 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 1 by 2 inch copper refrigeration pipe , p and w of expanded polyethylene foam tube insulation for 5 by 8 inch copper refrigeration pipe , s and f of prefabricated powder coated heavy duty iron stand having projection arm minimum 600 mm , s and fabrication of m.s. frame made out of various m.s. sections incl. hardwares finishing, painting, minor civil work etc , p and f of 12mm thick prelaminated particle board with decorative lamination on both side flat pressed 3 layer or graded wood particle board , s and l of 4 x 1.5 sq mm copper conductor unarmoured cable of 1.1