Get complete information related to latest Air Condition Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Condition Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Condition Repair Tenders.
Tender For corrigendum : providing of operation and maintenance of other machines and plants - comprehensive maintenance contract for the input coal feeding arrangement to washery (i.e. part of chp from reclaim feeder complex up to conveyor discharge chute at th-3) of lakhanpur ocp of lakhanpur area with allied auxiliary facilities such as all the associated systems and sub-systems like power supply, internal and external illumination, control & instrumentation, communication system, dust suppression system, firefighting and plant cleaning systems, pressurization & airconditioning system, ventilation system, material handling system (lifting tackles, hoist, monorail etc.), signaling & alarm system, control & monitoring system, plc, earthing & lightning protection system, sampling system, etc. of ilbl ocp of lakhanpur area, mcl.
Tender For supply of on/off rotary switch for airconditioning in lhb ac coaches rated voltage - 110v, rated current 6amps, position 2 , pole - 5 as per s. no. 58 of bill of material of rdso specn. no. rdso/pe/ spec/ ac/0184- 2015 (rev-1) suitable for use in switch board cabinet of lhb type ac coaches similar to part. no: 6a-s6-61198-b13-tdyr of salzer make. required make: salzer/kaycee/siemens. note: material should be supplied by oem or their authorised dealers only with uploading the oem's authorisation certificate while bidding.
Tender For corrigendum : providing of operation and maintenance of other machines and plants - comprehensive annual maintenancecontract i.e operation, maintenance,cleaning, security arrangement for theinput coal feeding arrangement towashery (i.e. part of chp fromreclaim feeder complex up toconveyor discharge chute at th-3)with allied auxiliary facilities such as allthe associated systems and sub-systemslike power supply, internal andexternal illumination, control &instrumentation, communication system,dust suppression system, firefighting andplant cleaning systems, pressurization &airconditioning system, ventilationsystem, material handling system (liftingtackles, hoist, monorail etc.), signaling &alarm system, control & monitoringsystem, plc, earthing & lightning protection system, sampling system,etc. of ilbl ocp of lakhanpur area,mcl
Tender For supply of auto manual bye pass,rotary switch for airconditioning ;current rating- 1 6a, position-3 (auto, manual, off) ,no. of poles-7 as per s.no. 192 of bill of material of rd so spec. no.rdso/pe/spec/ac/0184-2015(rev-0) and confirming to rdso spec no. rdso/pe/sp ec/ac/0184-2015 (rev-0) . suitable for use in switch board cabinet of lhb type ac coaches. make: l&t/salzer/kaycee/siemens [ warranty period: 30 months after the date of delivery ]
Tender For supply of roof mounted airconditioning system without 'trough' to specn no. rdso/2007/ el/spec/0055, rev '2' (material to be procured from clw approved sources only). [ warranty p eriod: 30 months after the date of delivery ]
Tender For annual contract rate for supply of building electrical fitting material - supply of building electricals fitting materials, pvc insulated cable fr with copper multi strand conductor isi marked 2x2.5 mm, pvc insulated cable fr with copper multi strand conductor isi marked 2x4 mm, pvc insulated cable fr with copper multi strand conductor isi marked 2x1.5 mm, pvc insulated cable fr with copper multi strand conductor isi marked 1.0 mm, approved make electronic dimmer/requlator for fan 650w, approved make electronic dimmer/requlator for fan 1000w, ceiling fan (energy saver 50 w)-1200 mm sweep, ceiling fan (energy saver 50 w)-1400 mm sweep, approved make wall mounting fan complete with wall bracket ,canopy,blades,speed regulator 400 sweep, approved make fresh air fanac 230-250 volts 300 sweep, approved make exhaust fan heavy duty with mounting frame,blades ac230-250 300mm sweep 900 rpm, approved make exhaust fan heavy duty with mounting frame,blades ac230-250 380mm sweep 900 rpm, servicing & overhauling of cooler fan motor, pump including replacemnt of distribution & delivary pipes,pvc elbows, painting etc. as reqd. complete with nacessary material & labour including replacement of connection leads., cleaning,overhauling, servicingof ceiling /exhaust /wall bracket fanby applying grease & oil, including testing with mounting / hanging arrangement including replacement of saftypins, checknuts,locknut,nut bolts etc. making perfect allignment & refitting at site as required., rewinding of fans by copper enamelled wire of suitable gauge including all required material, insulation, varnishing,connection leads,oiling .greasing etc completewith testing including dismentalling& refitting of fan at site.scrap old material is not returnable to the department., providing & refilling of wood wool /khas pads of normal size cooler panels 3 nos includings craping of oldpaint,making surface even,painting withred oxideprimer & two coats of paint of required shade including fixingnew wiremesh complete, chemical servicing of window /split airconditioning unit 1.5tr /2tr capacity including cleaning of cooling &condensing units,filters,grills etc & all other parts oiling & greasing of fan motor testing of a.c unit etc, cleaning,overhauling, servicingof ceiling /exhaust /wall bracket fan by applying grease & oil, including testing with mounting / hanging arrangement including replacement of saftypins, checknuts,locknut,nut bolts etc. making perfect allignment & refitting at site as required., labour rateforpointwiringalight /fan/twincontrol light /socketout let on seperateboard / call bell point in (open) surface rigid steel conduit system., labour rateforpointwiringalight /fan/twincontrol light /socketout let onseperateboard/callbellpoint inrecessed/concealed rigidsteelconduit system., labour rateforpointwiringalight /fan/twincontrol light /socketout let on seperateboard / call bell point in (open) surface rigidpvcconduit system., labour rateforpointwiringalight /fan/twincontrol light /socketout let onseperateboard/callbellpoint inrecessed/concealed rigidpvcconduit system., labour rateforpointwiringapowerpoint inrecessed/concealed rigidsteel conduit system including labour for fixing earth continuity conductor ., labour rate for fixing rigid pvc conduit as per specification in recessed/concealed conduit wiring system.20mm, labour rate for drawingcables inexisting rigidsteel conduit ( surfaceor recessed/concealed ) "a" 2 wires -1 2.5 sq mm / 4 sq mm / 6 sq mm, xlpe insulated power cable (conformingis-7098 ) 1100 volt grade/heavy duty powerc unarmoured 2 core 6 sqmm, led of 1 to 3w each assembled on single mcpcb, having color temp 6500k & having 50000 burning hrs life with minimum @l70,led luminiare 1 x 1, 24w , 4-6.5k, led of 1 to 3w each assembled on single mcpcb, having color temp 6500k & having 50000 burning hrs life with minimum @l70,led luminiare 2 x 2, 36w, 4-6.5k, led luminiare 1x1, 24w p