Tender For replacement of different old room airconditionermachines at the various places of the presidency small cause court, 2 and 3, kiran shankar roy road, kolkata-700001.
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditionermachine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditionermachine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as
Tender For corrigendum : supply of ac spare parts - - copper pipe dia inch x 0.7 mm thickness x 50 ft. make: godrej /totaline/carrier/daikin/camipro , un-armoured frls pvc insulated 2.55q. mm, 4 core flexible copper conductor as per is:694:2010 (100 m coil) make - havells / finolex/kei/ polycab 3 mfd capacitor (metal body), burst proof running capacitor for airconditioner application: a) voltage rating 440 v b) should be explosion proof c) built in pressure sensitive interrupter to be present in the capacitors d) terminals: tin plated e) material of construction entire body made up of aluminium with metal top make: tibcon / sarda/or equivalent isi marked , 4 mfd capacitor (metal body) burst proof running capacitor for airconditioner application: a) voltage rating 440 v b) should be explosion proof c) built in pressure sensitive interrupter to be present in the capacitors d) terminals: tin plated e) material of construction entire body made up of , aluminium with metal top make: tibcon/sarda/or equivalent isi marked. , 50 mfd capacitor (metal body), burst proof running capacitor for airconditioner application: a) voltage rating 440 v b) should be explosion proof c) built in pressure sensitive interrupter to be present in the capacitors d) terminals: tin plated e) material of construction entire body made up of aluminium with metal top make: tibcon/sarda/or equivalent isi marked. , gas charging pin inch diameter flare nut (brass) for air conditioning application 5/8 inch diameter flare nut (brass) for air conditioning application , ptc relay for godrej make refrigerator , ptc relay for lg make refrigerator , ptc relay for samsung make refrigerator , ptc relay for whirlpool make refrigerator , r-22 refrigerant cylinders (1 litre can) for air conditioning application, conforming to standard is-5610 :1983 with latest amendment. purity not less than 99% packing should be factory sealed in steel cylinder. make: godrej/floron/mafron / ecorane , universal remote for ac indoor unit. the remote should be ir compatible, battery powered, with operating distance minimum 8 meter make: phillips/ baba/godrej / carrier , strainer (copper application 0.5 mm thickness) for air conditioning , strainer (copper, 0.5 mm thickness) for refrigeration , aaa size alkaline battery with nominal voltage1.5 v, flat contact terminals as per iec - lr03 make: duracell/evaready/nippo , un-armoured frls pvc insulated 2.5sq. mm 3core flexible copper conductor as per is:694:2010 (100 m coil) make - havells / finolex / kei / polycab
Tender For providing and fixing (mitsubishi, hitachi, o general, carrier, daikin or voltas or equivalent make) split airconditioners (machine year-2025 model) of 2.0 ton capacity at pgvcl corporate office, rajkot