Tender For corrigendum : provn of uv enabled air purifier system in split acs, provn of hygiene and odour control exhaust fan for washrooms and repair/ replacement of geysers against ber at ahrr under ge e/m rr hosp. delhi cantt-10
Tender For corrigendum : providing of custom bid for services - hiring of services for comprehensive annual maintenance contract of duct-able split type package acs for drilling rigs of ankleshwar asset
Tender For two item-1- supply of universal pcb non-inverter type split ac of 1.5 ton capacity suitable for all make and models of acs.2- universal pcb inverter type 1.5-ton capacity split ac suitable for all make & models of ac.
Tender For supply of supply of examination table , supply of ecg machine , supply of crash cart trolley , supply of oxygen cylinder stand cum trolley , supply of pulse oximeter , supply of stethoscope , supply of double bottle suction machine , supply of medical oxygen cylinder , supply of emergency shower and eyewasher , 1 tonne split acs , supply of spine board , supply of ambu bag , supply of examination bed
Tender For corrigendum : provn of 2x split acs 1.5 ton and 01x deep freezer for server room and lab dept at sho and provn of defi airconditioning of wards depts at mh under age em of ge satwari
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to
Tender For round the clock operation and routine breakdown capital maintenance of airconditioning, ventilation system, package ac units, window/split acs, water cooler and assistance in o n m of lift and stack elevators at stps (o n m), suratgarh.
Tender For hiring of services for comprehensive annual maintenance contract of duct-able split type package acs for drilling rigs of ankleshwar asset for a period of 03 years (2026 – 2029)