Get complete information related to latest Air Cooling Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Cooling Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Cooling Machine Tenders.
Tender For epoxy painting for 5 nos of unitary air washer units 1 no blower in masonry air washer unit and 3 nos of cooling towers of chiller unit during aoh coh 2025
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to
Tender For request for proposal (rfp) for annual maintenance contract of different items/ instruments/ systems/ gadgets installed- chiller cooling tower fan motor , cooling tower , primary pump , seconadary pump , condenser pump , vfd controller secondary motor , cooling tower make up tank pump , presurization pump , plant room fresh air fan , csu , 1 way chiller line cassette a/c , 1 way chiller line cassette a/c , 4 way chiller line cassette a/c , 4 way chiller line cassette a/c , 4 way chiller line cassette a/c , 4 way chiller line cassette a/c , chilled water hi wall unit , vrf hi wall in door unit , vrf hi wall out door unit , vrf hi wall out door unit , split a/c , split a/c , split a/c , smoke exhaust fan , smoke exhaust fan , smoke exhaust fan , ceiling mounted exhaust fan , cabinate centrifigal fan for all the floor toilet ty-02 ventilation , ventilation , vrf hi wall out door unit , vrf hi wall out door unit , vrf hi wall out door unit , vrf hi wall out door unit , vrf hi wall in door unit , vrf hi wall in door unit , vrf hi wall in door unit , vrf hi wall in door unit , round flow cassette , round flow cassette , round flow cassette , 1 way vrf cassette a/c , compact cassette , ductable a/c unit , ductable a/c unit , ductable a/c unit , ductable a/c unit , tfa , tfa , split a/c , split a/c , scrubber unit , scrubber unit , fresh air fan , fresh air fan , fresh air fan , in line fan , in line fan , in line fan , in line fan , chiller-1 , condenser pump , primary pump , secondary pump , cooling tower motor , ahu , csu , split a/c , fcu , ht panel , vcb , acb(i) four pole , acb(ii) three pole , acb(iii) three pole , acb(iv) four pole , main lt panel , dg synchronization panel , 2000 kva, 33/0.4 kv transformer , bus duct , tap up box , rtcc panel , 600 kvar apfc panel , lt panel , lift panel , fire mcc panel , pump panel , main mcc panel (stp) , chiller main panel- 1 , chiller main panel- 2 , chiller main panel- 3 , chiller main panel- 4 , chiller main panel- 5 , colling tower panel , csu main panel , floor main distribution panel (i) , floor main distribution panel (ii) , lift sub panel , 10 kva ups , 20 kva ups , 40 kva ups , 60 kva ups , 6 kva ups , diesel generator set with battery , dg colling tower , diesel tank , lt panel- 1 , lt panel- 1 , ups panel , stater panel , 125 kvar apfc panel , isolator panel , 2000 kva, 11/0.4 kv transformer , main lt panel , dg synchronization panel , 600 kvar apfc panel , lt panel , lt sub panel , lt sub panel , lt sub panel , lt sub panel , pneumatic pump , centrifugal pump , centrifugal pump , submerssible pump , submerssible pump , water purifier cum cooler
Tender For epoxy painting for 5 nos of unitary air washer units, 1 no blower in masonry air washer unit and 3 nos of cooling towers of chiller unit during aoh / coh 2025 - 26.
Tender For sale of incubator (memmert type) model: pew-60m (b) s. s. , axioscope h microscope with photoghrapetic accessories , horizontal laminar flow clean air workstation with s.s. table, uv light model 1500c-48-24-24 , electroquip' autoclave vertical laboratory: - size 35 x 55 cm complete unit model s.s. eq 141 , lab hot air oven, size 24" x 24" x 24" with air circulation and digital temperature controller , electric loop sterilizer , sartorius make semi micro balance, model: bp 210 d , pcr thermal cycler, model: ptc-1152 , vortex mixture vx 100, 200-300 rpm , heat sealer no. 5390000024 230w/50 hz film no. 0030127650 , -white light trans illuminator 25 x 25cm, code 107172 , ph meter, ph test 10 water prof, ph tester, 10 tester , microcentrifuge (m.c.i.) cat no. 107110 of bangalore genei , remi make magnitic stirrer with hot plate model 1 mlh , remi make research centrifuge pr-24, microprocessor-controlled centrifuge with standard accessories , spinwin micro centrifuge-tarson 6 x 1.5 , spiner mini micro centrifuge , ups 500 va (hi-safe) , protek make line interactive offline ups 2.5 kva input dc 24, vdc with 45-50 minimum backup , power ware ups 6 kva , elite power supply 300-230 v, output range 10-30, 4-400 ma, code no. 1001004 , suvik make automatic servo stabilizer 75 kva , refrigerator (godrej)-165 liter model: 165l gc , samsung ref 230 ltr, rt-23 fvd bi/xtl, (freedge) , mini magic super water cooler voltas make sr. no. , 6210009m08 +114770 , l. g. make double door refrigerator, model 325 tm , blue star storage water cooler, model sdlx15 stainless steel 15 ltr. cooling & 15 ltr. storage , l. g. refrigerator 280 ltr., model ref 298 lng4 super ino , lg silver ultima 305 vvs refrigerator ff 290 liter , 30 gdp airbat five-star r. o. system , lg refrigerator 360 ltr. model d-402rshm (sv) , amtrex shizuka window a.c. 2.0-ton, item code-a1bj10cs , lg air conditioner lsa11851 rae1 (split a.c) , l.g. ac split 2.0 tons lsa 2481 , l.g. make split a.c. 2.0-ton b24xwasi-83 dvi , l.g. make split a.c. 1.5-ton 18xwas-1-ae , lg multi split a.c. 2 ton, lna-24 twasia , lg make split a.c. 2.0 ton, model - 6vb1vf1 , voltas vertis split air conditioner 2.0 ton , easy chair wooden with nylon wire neated seat & back , steel cabinet chandan (minor) , a) wooden class-ii table-01 nos. , b) writing table size 4.6' * 2.8' * 2.5' - 1 nos. , godrej steel shelving rack, size 7.3 ^ prime prime *36^ prime prime *18 , eagle steel cup board:- size 78 "*36"*19" with 4 shelves , steel file rack , godrej navtal pad lock , a) 6 lever-2 nos. , b) 7 lever-2 nos. , c) 7 lever-1 nos. , chandan rack om-40 , chandan steel table (office table) ot-60 g2l2r1 wooden with veener , top , chandan paper tray om-10 , chandan office chair 25 , steel tray without cover size 350 * 250cm , vaccum filter holder, stainless steel, 47 mm dia cap. 250 ml , (a) white board writing system, size 1.5' * 2' - 1 nos, , (b) white board writing system, size 3^ prime prime * 4' - 1 nos. , rotor head + adapter, , (a) tc 453, 4 x 50 swing out rotor head suitable for tc 450 centrifuge, , (b) tc 476: set of reduction adpeter to carry 30 glass tubes suitable for tc 453 rotor head , bunsen burner with stop cock , slotted angel adjustable rack , revolving high push chair , fix visitor's chair (blue gadi), model no. 5vh-101 , ken star microwave oven, 20 acf , wooden table , 3 kva single phase servo stabilizers , fix visitor chair , crompton acgic crest induction cooktop 1500-watt, model: crest
Tender For corrigendum : supply of c73240000350 supply of high performance wall mounted pac unit air cooled dx type precision cooling units of capacity min 2 tr refer annexure iii , 100000000000 supply of interconnecting hot gas and liquid gas copper piping between indoor and outdoor unit refer annexure iii , 100000000001 supply of interconnecting copper cabling for power control panel of xlpe insulated refer annexure iii , 100000000002 supply of interconnecting copper cabling between indoor and outdoor unit with fitting and accessories for indoor blower refer annexure iii , 100000000003 supply of interconnecting copper cabling between indoor and outdoor units for hp,lp, a1 , a2, blower fan alarm etc refer annexure iii , 100000000004 supply of cpvc condensate drain piping 25mm with 9mm insulation in building area along with fitting and accessories refer annexure iii , 100000000005 installation testing and commissioning of high performance wall mounted pac unit air cooled dx type precision cooling units of capacity min 2 tr refer annexure iv , 100000000006 installation of interconnecting hot gas and liquid gas copper piping between indoor and outdoor unit along refer annexure iv , 100000000007 installation of interconnecting copper cabling for power control panel of xlpe insulated pvc sheathed refer annexure iv , 100000000008 installation of interconnecting copper cabling between indoor and outdoor unit with fitting and accessories for indoor blower refer annexure iv , 100000000009 installation of interconnecting copper cabling between indoor and outdoor units for hp,lp, a1 , a2, blower fan alarm etc refer annexure iv , 100000000010 installation of cpvc condensate drain piping 25mm with 9mm insulation in building area along with fitting and accessories refer annexure iv ) /bid number: gem/2025/b/6951804 * /dated: 02-12-2025 & & / bid document1 / 13
Tender For supply of spares refrigerant gas r407c with cylinder qty:-07 kg per cylinder , shaft seal cover, part no.- , ac926100076, make:- voltas for ac plant compressor model no. 05066-s , 5h s.s. assly with ring, part no.-ac926101800, make:-voltas for ac plant compressor model no. 05066-s , pillow block bearing for ahu of service building ac plant , cleaning chemical (copper safe) for chiller/condenser of ac plant , pillow block bearing model-ucp 205 for ahu of switch yard control room ac package , v belt a-28 , seal cover plate , p.no:ac926100076 make: - voltas for ac plant compressor model no. 05086 , shaft seal assembly , p.no:ac926101800 make: - voltas for ac plant compressor model no. 05086 , charging hose 1/4" connecting (set of 3) for central ac plant , 1/4" charging nrv valve for central ac plant , liquid line filter, make: , voltas for ac plant compressor model no:05086 , v belt b 85 , v belt a-30 , liquid line filter model-165 for uniflair and blue star make package ac unit and hydrogen gas dryer unit , dryer model dcl-083. code.02325005.for blue star make package a.c5.5 ton. , tyre element for fenner make f-80 tyre coupling , refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , connecting valve for refrigeration oil charging pump suitable for voltas make ac plant compressor model no. 05086 , 3-way manifold gauge set with 3 charging hoses for r22, r134a, r407c for central ac plant , gas cylinder valve spindle key , gas cylinder adaptor for r-22 gas cylinder , gas cylinder adaptor for n2 gas cylinder , air cooled condenser model no: dc85s, capacity: 8.5 tr, make: voltas for 132kv switch yard control room ac package , pedstal bearing size-ucp209d1 for cooling tower of contol room ac plant , brass float valve size: 20 mm (3/4??) , ratchet wrench (4 size: 1/2-inch hex, 9/16-inch hex and 1/4-inch square, 3/16-inch square) , fenner make v belt size b-98
Tender For ttps operation circle cad cwph i unit i annual overhauling of 1200 mm butterfly valve and actuators, air releasing valves and other gate diaphragm valve of cooling water system of unit i
Tender For ttps operation circle cad cwph i unit ii annual overhauling of 1200 mm butterfly valve and actuators, air releasing valves and other gate diaphragm valve of cooling water system of unit ii
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim