Tender For supply of fog light assy m and m scorpio,water pump fan belt,fuel filter cum water saparator,oil filter cartridge,baby filter,self stator 24v,gear box overhauling of 2.5 ton tata,transfer case overhauling,denting and painting of maruti gypsy includng complete body inner side roof repairing and floor matting,repairing of fuel injecton pump 2.5 ton tata
Tender For supply of tie rod shaft lh , tie rod shaft rh , ball join kit sumo , needle bearing , spider bearing inner , dual brake valve , flexible bush for mtg bracket lh or rh , s or a of socket lh , s or a of socket rh , relay 24v , end assy , throttle body cleaner , steering pump , head cylinder gasket , high intensity reflective tape , sump heater 24v , reduction winch swc , filter assy , door beeding , hub nut bolt , pneumatic relay valve , front brake pad , rear brake pad
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
Tender For supply of tractor new holland spandle left , tractor new holland spandle right , tractor new holland water body , tractor new holland radiator , tractor new holland hose pipe kit , tractor new holland driver seat , tractor new holland tie rod goli , tractor new holland engine fan , tractor new holland hydraulic pump , tractor new holland oil filter , tractor new holland fuel filter , tractor new holland fan belt , tractor new holland hub bearing small , tractor new holland hub bearing big , tractor new holland mudguard light , tractor new holland head light bulb
Tender For procurement of spares for mill lube oil tank for ytps - viton o-ring kit for mill los and mill reject, metal bonded seal washer kit for mill lube oil line, face type body level oil guage for mill lop tank, mill lop inlet line filter strainer flange 6 inch, desiccant breather for mill lop tank