Web Analytics Made Easy - StatCounter

Alarms Tenders

Get complete information related to latest Alarms Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Alarms Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Alarms Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39171113 Due date: 03 Mar, 202503 Mar, 2025 1.80 Crore
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene

CTN :39129069 Due date: 26 Feb, 202526 Feb, 2025 NA
Tender For corrigendum : supply of workstation pc , traffic display 27 inch monitor operators , vts keyboard , speaker 5w , display 42 inch monitor , operator furniture console and chair , navi harbour remote terminal basic sw , ors3 radar video presentation sw module , rt navigation alarms , enc charts tads similar to copt license, 4 years license , rt user chart , training on vtms , installation and commissioning

Central Government/Public Sector

CTN :39393809 Due date: 17 Mar, 202517 Mar, 2025 NA
Tender For supply of material and execution of indoor & outdoor work for provision of electronic interlocking-msdac based automatic block signalling system between bishangarh station(excl.) to marwar kori station in connection with doubling of ln-smr-bldi section of jodhpur division of north western railway. the work involves provision of new electronic interlocking at jalore, marwar bagra, moderan, bheempura, ledarmer, marwar bheenmal, marwar kori stations along with thirteen numbers of auto signalling huts . provision of msdac parallel with dc track circuit in yards & dual msdac in block section associated works like trenching & laying of signalling and telecom cables in pre-fabricated ducts/dwc/gi pipes, supply-installation of point machines, apparatus cases, electric lifting barrier gate, signals, track circuit equipment, earthing material, data loggers, eld, fuse alarms, fire alarms, passenger amenity telecom items etc.

Central Government/Public Sector

CTN :39350502 Due date: 25 Feb, 202525 Feb, 2025 NA
Tender For supply of display card of automatic fire detection and alarms system. spec: rdso/spn/217/ 2021 ver 3.0, str: siq 0211 ver 1.0. [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :39320905 Due date: 22 Feb, 202522 Feb, 2025 22.45 Lacs
Tender For providing of custom bid for services - : integrating two ethanol pumps with above-ground tanks for automated delivery at the tlf, including aninterlocking system for the ethanol tank during itt from the above-ground tanks, as well as interlocking the ttdecantation point mov to level alarms and

Central Government/Public Sector

CTN :39269241 Due date: 01 Mar, 202501 Mar, 2025 6.26 Lacs
Tender For repairing and supply, installation, testing and commissioning of furnishing, electrical and fire alarms system works

Central Government/Public Sector

CTN :39203633 Due date: 28 Feb, 202528 Feb, 2025 NA
Tender For supply of material and execution of indoor & outdoor work for provision of electronic interlocking-msdac based automatic block signalling system between luni jn and bishangarh station in connection with doubling of ln-smr-bldi section of jodhpur division of north western railway. the work involves provision of new electronic interlocking at satlana, dudia, dundara, ajit, bamsin,rakhi, mokalsar, balwara,bishangarh stations and samdari jn. along with fifteen numbers of auto signalling huts and modification in existing medha make ei at luni jn. provision of msdac along with associated works like trenching & laying of signalling and telecom cables in pre-fabricated ducts/dwc/gi pipes, supply-installation of point machines, apparatus cases, signals, track circuit equipment, earthing material, data loggers, eld, fuse alarms, fire alarms, passenger amenity telecom items etc

CTN :39154282 Due date: 20 Feb, 202520 Feb, 2025 NA
Tender For supply and installation of biotechnology instruments - bod incubator with stabilizer:- features available in bod incubator - toughened glass window ,air circulation fan ,removable tray ,temperature,sensor ,door hinges ,pid temperature controller. 2 optional features available in bodincubator stainless steel perforated trays no of trays 3 air circulation motorized blowerexterior body material mild steel and painted in epoxy powder coating insulation material glass woolouter door material mild steel inner door material material of removable traytoughed glass material of removable tray stainless steel wire mesh tray chamber capacity(in ltr) 250-299 thickness of sheet (in mm ) 0.7 thickness of toughed glass/acrylic sheet (in mm ) 7 diameter of stainless steel wire in mesh ( in mm )3 temperature range 10 c to 70 c temperature accuracy 0.5 ctemperature uniformity 1 c., cooling centrifuge 20000 rpm with rotator head and stablizer :- type of motor brushless(without carbons)type of lid lock both manual and electronicno of acceleration and deceleration profiles in built for rotor speed while automatic brakingoption to accelerate and decelerate speed at various rates configuration of rotor supplied with centrifuge machine angle rotorsize of rotor supplied with centrifuge in ml"12x15ml(for angle rotor) rpm 13000"warranty period for equipment & roto condensed water drainage system,the equipment shall be installed and demonstrated before acceptance, servo controller voltage stabilizer supplied with item, deep freezer with stabilizer :- type vertical features puf insulation,frost free capacity ( l) >=250l temperature range in c -10 c to -40 c or better temperature uniformity in degree celsius +/- 3 c or lesstemperature stability of system in degree celsius +/- 3 c, rotatary shekar incubator with stabilizer :- castor wheels ,range of temperature5 degree centigrade to 60 degree centigradetype of display lcd, type of speed controlstepless continuously variable,orbital shaking amplitude in mm25 mm,type of flask which can be accommodated 100 ml ,250 ml ,500 ml ,1000 ml ,2000 ml, interior illumination led bulbs,construction of body double walled with inner and outer walls,door insulated double walled door with glass window,internal length of equipment in mm 765internal width of equipment in mm 660internal height of equipment in mm 650outer length of equipment in mm 1150ouiter width of equipment in mm 800outer height of equipment in mm 1300,range of temperature 5 degree centigrade to 60 degree centigradetemperature accuracy plus minus 0.5 degree centigradetemperature controller microprocessor based digital temperature controller and indicatortype of sensor pt -100,ype of motor brushless motorshaking mechanism controller microprocessor controllerorbital shaking speed in rpm upto 250type of speed control stepless continuously variableincrement of step variation 10orbital shaking amplitude in mm 25 mmtimer adjustment in hours 99, autoclave vertical :- chamber capacity/size approx. 80-120 litersoperating pressure 15 - 20 psipressure gauge type analog pressure gauge (0 - 400) psi temperature accuracy +/- 0.5 c (at 121 c)operating temperature (max) 123 c features automatic start/stop timer,low water level heater cut-o and alarms,over pressure cut-o with audio-visual alarm,low heat warning,inner temperatureindicator,over temperature cut-o with audio-visual alarm,door cannot unlock until chamber pressure reaches room pressure,temperature calibrationfunction spares & accessories perforated corrosion free basket made up of ss 304 (3-4 nos) that arestackable two high or more levelsadditional requirement calibration certicate from iso17025 accredited lab for temperature,pressuregauges & timer, heating element multicombine:- power source electric material ceramicapplication heating shape rectangulardimension diameter 200 millimeterwidth 200 millimeter thickness 8 millimeterlength 600 millimeter specications resistance 5 operating power 100 kilowatt

Central Government/Public Sector

CTN :39140907 Due date: 28 Feb, 202528 Feb, 2025 NA
Tender For supply of bipap machine include user adjustable alarms&essential non-adjustable, fixed alarm for patient safety
 Loading, Please wait...

Connect us via What's Up