Tender For corrigendum : strengthening of (e/m) equipments of various tube wells installed at babu park kotla area under kasturba nagar constituency ac-42 . - s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.make: - tata/jindal, supply of out door type 7.5 to 10hp hut type electrical feeder pillar/metal board of welded construction of size 1370mm x 760mm x 460mmfabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size onsuitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, vermin proof having following items.1. mccb 63 amp, 4 pole-1 no2. rccb/elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no4. digital ampere meter 96mmx96mm square shape of 0-30 amp range 1no5. digital voltmeter of 96mm x 96 mm square shape of 0-500 volt range with selector switch 1no6. led indicating lamps with fitting (a set of 3 lamps) 1set7. shunt capacitor of 5 kvar with three phase isolator 1no8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection. 1no9. programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p.1no10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc.as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame.make:-all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved.djb item code 10.2.1, supply of pvc insulated pvc sheathed copper conductor flat cable size 3 core x 4sq mm,1100 volts, confirming to is 694(each roll 100mtr long) make: finolex / havells./kei/any djb approved make., s/o nut bolts,washer dia 1 long full threaded, s/o rubber packing 50 mm dia. flange., lowering and lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material (rubber packing and nuts bolts) will be arranged by the firm as per site requirement. the other material required during execution will be provided by department.
Tender For supply of insulating base with fixing screw kit, for coupling socket assembly of inter-vehicular coupler of lhb eog coaches, as per rcf drawing no. lw71303 alt-
Tender For strengthening of e/m equipment of various tube wells installed at sarai kale khan area under jangpura constituency ac-41. - supply of double flange gi column pipe 50 mm dia medium class each of 3 mtrs long duly threaded on both ends, welded fitted with gi flange on both ends and welded support l-type ms bracket in both flange with slot of submersible cable.make: tata/ jindal. , supply of out door type 7.5 to 10hp hut type electrical feeder pillar/metal board of weldedconstruction of size 1370mm x 760mm x 460mmfabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size onsuitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, vermin proof having following items.1. mccb 63 amp, 4 pole-1 no2. rccb/elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no4. digital ampere meter 96mmx96mm square shape of 0-30 amp range 1no5. digital voltmeter of 96mm x 96 mm square shape of 0-500 volt range with selector switch 1no6. led indicating lamps with fitting (a set of 3 lamps) 1set7. shunt capacitor of 5 kvar with three phase isolator 1no8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection. 1no9. programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p.1no10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc.as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame.make:-all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved.djb item code 10.2.1, supply of pvc insulated pvc sheathed copper conductor flat cable size 3 core x 4sq mm,1100 volts, confirming to is 694(each roll 100mtr long). make: granlay / havells./gloster/any djb approved make., supply of nut bolts, washer 1/2 dia 1 long full threaded., supply of rubber packing 50 mm dia. flange., lowering & lifting of sub/sets from bore by taking out double flanged gl pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gl pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material will be arranged by the firm as per site requirement. the other material required during execution will be provided by department. djb sor(e&m)-2022 item code 27.1.2
Tender For supply of various electrical consumable items for emd 3 & emd-5 at wtps, gsecl. - jyoti make voltage operated auxiliary relay type re-300, voltage: 220 v dc with 4 c/o contacts without plug in base with optional led indicator, plug in type relay make paramount coil voltage 110 v ac 50 hz., plug in type relay, "paramount" make, coil voltage - 24 v dc, with 2 c/o contacts, type-p3-2-pz-m-24 v dc with led & relay base., plug in type relay, "paramount" make, coil voltage- 240 v dc, with 3 c/o contacts, type-p3-3-fpzi -240 v dc with led & relay base., oks contact cleaner [ 2621 /2 ] size 500 ml [ 275 gms ] spray bottleman u oks speciality lubricants { india } pvt. ltd., wd 40 size 340 gms spray bottle manu hardcastle & waud mfg . co . ltd, crc-226 contact cleaner in 415 ml/300 gram spray bottle., red insulating varnish-class f epoxy insulation & protection coating., becktol gray varnish in 1 ltr tin dr.back make, thinier 221, 901 easyclean (nf) 500 ml. spray can - on line electrical contact cleaner., puff seal have polyurethene based foam sealing compound, silica gel blue 4 to 6 mm, heat shrinkable sleeve,size:45mm/18 mm( for 240/300 sq.mm )for 11 kv, mcb 4 pole, 32 amp, 440 volts, breaking capacity 10 ka, mcbs(3 pole+nutral) miniature circuit breker current rating 63amp., mcb 1 pole 25 amp,l 43125 ro, plug socket 6 amp 230v,5 hole, 3 pin plug top 6amp. 4657, single way switch 230 v, 6 amp. confirming is 3854., pvc adhesive insulation tape roll, ceiling fan capacitor, change over switch 63a x 415v x 4 pole, ictp switch 415 volts,100 amp. t.p. heavy duty., lighting panel with 18 outgoing c.k.t., supplied with double door,insulated busbar,insulated neutral bars,earth bar,cable ties,circuit identification lables, industrial padestal fan, wall mounting fan smart looks flexible tilting neck with toggle switch for oscillation control metal blades 230v 50hz. power saver., 4 pole, 100 amp, 415 volt, ac 23 a, 4p l&t make manual changeover switch ,disconnector, size fr1, catalogue no : co11000oooo, (conforms to iec 60947-3, is/iec 60947-3 ),type : open execution, push button station surface mounting type 3sb08 02-8ac, start-stop positions, siemens make, start push button green make:esbee ,230v,6a with n0 contact element, stop push button red make:esbee ,230v,6a with nc contact element, led type indication lamp, 22.5 dia, 240 v ac, red colour with lvgp, led indication lamp 22.5mm dia colour:-red voltage:-110vac make:-l&t cat no.:-eplr110a, 4 switch and 1 socket pvc switch board, 4 switch and 4 socket pvc switch board, ht pvc insulation tape size 0.18 mm x25 mm x 65 mtr length, 2 switch pvc switch board, 3 core , 6 mm sq. flexible pvc insulated copper cable, flexible unsheathed pvc insulated copper cable of size 4 corex6 sqmm, 1.1 kv busbar /cable couductor protection heat shrinkable sleeve dia .before shrink: 50 mm dia. after shrink : 16 mm for 1.1 kv lt cable, pvc flat copper cable 3 corex35 sqmm for submercible pump, 1100 v grade, multi-stranded, unarmored flat copper cable, pvc insulated, for submersible pump, as per is 694, 1990 size :3 c x 70 mm2