Web Analytics Made Easy - StatCounter

Aluminium Alloy Conductor Tenders

Get complete information related to latest Aluminium Alloy Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminium Alloy Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminium Alloy Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45374834 Due date: 12 Jun, 202612 Jun, 2026 9.95 Lacs
Tender For repair/ maint of lt over head line, lt pole and busbar with connected accessories at hq igar (e) srikona. - schedule a part - i, supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 25 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 35 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 50 sqmm 3.5 core, complete including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 70 sqmm 3.5 core including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., m&l for preparation of surfaces of pole for painting of steel tubular pole,vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by engineer-in-charge on poles and numbering with writing letters or figures(block) complete all as directed., s&f street light control panel confirming to ip 66 protection mounted on wall/pole/pcc foundation with suitable ms clamps & nut bolts etc installation and testing including 01 no mcb tpn 63 amp (incomer),01 no contactor 63 amp 3 pole , 230v 3p module astronomical time switch , bakelite fuse fitting with 2 a hrc fuse,indicaion lamp,mounting lugs,panel lock,hinged door,auto manual selector switch 6 amp, detachable mounting din channel,supply monitoring device complete all as specified and directed, supply and fix high efficient ip-66 led street light 70 watt with high power leds, having aluminium pressure die cost housing and pc cover in the front and lens for light distribitioon and saving of energy efficient including service bracket and making of fixing arrengement all as direct by engr -in-charge., labour only for stringing loose lt line alumunium conductors as per direction of engr- in -charge, supply and fixing lt line separator 1100 volts of approved brand and quality, supplying and erection of 100 mm x 65 mm pin insulator complete with g. i. spindle and nuts etc as required .

Central Government/Public Sector

CTN :45146450 Due date: 08 Jun, 202608 Jun, 2026 46.36 Lacs
Tender For corrigendum : special repair to overhead acsr conductor to ug cable work at deccan offrs mess under age em i of ge(utility) secunderabad

Central Government/Public Sector

CTN :45375193 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For maint and repair of street lights security lights and solar lights and its connected items including repair to lt distribution network at mh and 41 arty div under ge mh and rh khadki - taking down old unserviceable lt ug cables of size upto 50 sq mm from trenches / poles / ducts etc complete all as specified and directed., supplying, laying, jointing, commissioning and testing xlpe insulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to is-7098 (part-i-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by engr in -charge for following sizes . make :- polycab/havells / gloster / finolex note :- earth work , bricks , riddled earth , gi pipe for protection of cable will be measured & paid under relevant items of schdule . , 50 sq mm 3.5 core ., 35 sq mm 3.5 core, 25 sq mm 3.5 core, 16 sq mm 4 core., 10 sq mm 2 core, 6 sq mm 2 core, excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed., ditto item no 3 but in hard/dense soil., removing excavated material soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed, returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed., material and labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. note - punned thickness shall only be measured & paid ., material and labour for road cutting/foot path and making good with pcc 1:3:6 type c-2 ( using 40 mm graded stone aggregate ) of 150 mm depth complete all as specified and directed., supply and laying un-reinforced precast concrete cable cover lv, type i, flat, size 250mm x 150mm x 40mm for under ground cable all as specified and directed., supply and laying gi tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed, ditto item no -10 but 80 mm bore., material and labour for plain cement concrete (pcc) 1:3:6 type c2 using 40mm graded stone aggregate for making foundation of pole/stay assembly complete all as specified and directed., material and labour for plain cement concrete (pcc) 1:3:6 type c1 using 20mm graded stone aggregate for making copings of poles etc complete all as specified and directed. ., material and labour for earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level, connected to the earth lead wire 4.0 mm dia (gi wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of gi medium grade pipe 15 mm bore including provision of 40 mm thick cover of rcc (1:2:4) 20mm graded stone aggregate re-inforced with xpm (weight not less than 4 kg per sqm) and frame of angle iron 40x40x3 mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape, gi light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate no 3 of ssr 2009 part-i and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. , material and labour fo

Central Government/Public Sector

CTN :45363602 Due date: 19 Jun, 202619 Jun, 2026 42.00 Lacs
Tender For repair replacement of internal wiring point wiring and sub main wiring including connected items at zone b otm and md accn at ins rajali under ge m arakkonam - taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. all as specified and as directed., material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :- make of cable : plaza/polycab/finolex/ havells, one light/ fan/ exhaust fan/ buzzer point controlled by one switch., one 3 pin socket outlet 6 amps, independent board with cables 1.5 sqmm size., one 3 pin socket outlet 6 amps,same board with cables 1.5 sqmm size., one light point controlled by two 2- way switches, with cable 1.5 sqmm size., all as per item ser no-2 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size.make :- polycab/finolex/plaza/havells, material and labour point wiring with 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor drawn into pvc conduit and casing & caping fixed on wall/roof/ceiling including wall cutting etc of size not less than 20 mm dia including provision of 1.5 sqmm single core pvc insulated frls unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :- make for pvc casing & caping: sudhakar / avon plast /plaza , make for copper cable: finolex/polycab / plaza., one light point controlled by one switch., one 3 pin socket outlet 6 amps, indipendent board with cables 1.5 sqmm size., all as per item ser no-4 above here in before but one 3 pin socket outlet 6/16 amps, indipendent board with cables 4.0 sqmm size. make :- polycab/finolex/plaza, m&l for sub main wiring for phase and neutral with pvc frls insulated unsheathed multi stranded along with earth wire frls pvc insulted copper conductor, single core cable in and including surface/concealed /pvc conduit appropriate size including cutting chases on brick walls concrete if required/ necessary surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishesas specified for the following sizes. make for copper cables: finolex/polycab / plaza/ havells. make of pvc conduit: sudhakar/finolex/avon plast., 2x 1.5 sqmm and 1x 1.5 sqmm as earth wire, 2x 4.0 sqmm and 1x 4.0 sqmm as earth wire, 2x 6.0 sqmm and 1x 6.0 sqmm as earth wire, 2x 10.0 sqmm and 1x 10.0 sqmm as earth wire, 4x 10.0 sqmm and 2x 10.0 sqmm as earth wire, 4x 16.0 sqmm and 2x 16.0 sqmm as earth wire, taking down existing rusted switch board sunken box from site including removing fixtures and fittings such as switch, socket fan regulator complete, removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces necessary plaster, white wash matches with existing colour of wall, floors, etc. all as specified and as directed., supply and fixing in repair of gi metal flush box suitable for mounting moduler plate of following modules:-, 1 or 2 module, 3 module, 4 module, 6 module, 8 module, 12 module, supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes for following modules:-, c

Central Government/Public Sector

CTN :45365822 Due date: 19 Jun, 202619 Jun, 2026 39.99 Lacs
Tender For repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches/duct/pipe inc

Central Government/Public Sector

CTN :45384669 Due date: 20 Jun, 202620 Jun, 2026 15.00 Lacs
Tender For repair/maint of lt network, lt panel, acsr conductor, ug lt cables at different locations at rampur, uri and naugam under ge 969 ews

Central Government/Public Sector

CTN :45382837 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking capacity with

CTN :45382308 Due date: 03 Jun, 202603 Jun, 2026 19.91 Lacs
Tender For repair/ replacement work of damaged acsr zebra conductor of 220kv s/c barmer-mpt line at loc. no. 58 ( tension tower ) on urgent basis

Central Government/Public Sector

CTN :45363607 Due date: 19 Jun, 202619 Jun, 2026 14.65 Lacs
Tender For special repair work to building no mes-24/c (jco mess kitchen) and special repair to oht conductor to ug xlpe cable and allied wks at mil stn jamshedpur under ge ranchi

Central Government/Public Sector

CTN :45376434 Due date: 20 Jun, 202620 Jun, 2026 50.00 Lacs
Tender For comprehensive maint and periodical services for stn hq reasi and minor units and repair/replacenent of lt panels, cables, earthing poles and overhead conductor of sila grn under age reasi of ge nagrota
 Loading, Please wait...

Connect us via What's Up