Tender For corrigendum : tender for supply of ac under voltage_over voltage circuit of solid state sensing type alv-d2 for ov , input surge protection network (mov based) in-20ka , imax-40ka up-2.2kv , current transformer 80 a / 5 a , cl 1.0 , 5 va , current transformer for ac ammeter am1 , 75a/5a , cl1.0 , 5va , emc filter (ac side) (mf-423-3-3d-80a-440vac , case r4) 440 v , 80 a ac , emc filter (ac side) (mf-423-3-3d-60a-440vac , case r7) 440v/60a ac , surge suppressor mov for ac input 275 v/20d (mov1-3) , surge suppressor mov for ac input 510v ac (k510) (mov 4-6) , control transformer for ac auxiliary supply 456 / 240vac , 500va , cooling fan with fan failure alarm contact 230v ac , 6 inch , 50w , 3ph , ac power capacitor 7.5kvar , 480v , 3ph , ac power capacitor 10kvar , 480v , ac reactor for pfc1 25a , 1550 micro henry , three phase , double wound , impregnated naturally air cooled mains transformer 50.03 kva (456/300v) , three phase , double wound , impregnated naturally air cooled mains transformer 38.21kva (456/40v) , semi-conductor hrc fuses for the rectifier bridge 80et , 690v , semi-conductor hrc fuses for the rectifier bridge 690v/500a (500mmt) , rectifier fuse fail detector circuit for rectifier fuse 220v dc , rectifier fuse fail detector circuit for above fuse 24v dc , diode skkd101/16 , scr1 12 425 a 12nos (425a/1000piv) , d1 300a 300a/600piv , interphase transformer 1.238kva , interphase transformer 1.13kva , shunt for cpc1 , cpc2 sh 100a/75mv , shunt for cpc1 , cpc2 sh 600a/75mv , bleeder resistance 350 ohm 750w 2 in parallel , bleeder resistance 50 ohm 100w 4 in parallel , bleeder resistance 2k 50w 2 in series , bleeder resistance 50 ohm 50w , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function , dc overload circuit of solid state sensing type for 110 percent overload alarm and trip function 230v ac 744 a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 177a , dc overload circuit of solid state sensing type for 150 percent overload alarm and trip function 230v ac 1014 a , filter choke 118 a 650 micro h , filter choke 676 a 16.5 micro h , filter condenser fuse fail detector circuit 220v dc , filter condenser fuse fail detector circuit 24v dc , 3 phase scr full controller card for scr firing 220v dc , 3 phase scr full controller card for scr firing 24v dc , 2 c_o plug in type auxiliary relay with base for ineterlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.4v function and interlock 240v ac 2c_o mpc , 2 c_o plug in type auxiliary relay with base for b2.75v function and interlock 240v ac 2c_o , double disk type wire wound potentiometer to adjust output voltage in float mode 10k _3w , potentiometer pcb for voltage control circuit for cpc1 and cpc2 mt 120a , potentiometer pcb for current control circuit for cpc1 and cpc2 mt 121a , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc over voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , rectifier dc under voltage circuit of solid state sensing type for alarm indication pfc and trip function , 2 c_o plug in type auxiliary relay with base for trip latch function 240v ac 2c_o mpc , charger silicon blocker diode diode skr300_12 , 300a_1200 piv , 2 c_o plug in type auxiliary relay with base as contact multiplier for mccb4 220v dc 2c_o , load under voltage circuit of solid state sensing type for alarm indication and pfc , load under voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for alarm indication and pfc , load over voltage circuit of solid state sensing type for pfc and tri
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on "semi turnkey basis" under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as jointing sleeve binding wire, armour rod etc.
Tender For supply of provn of prefabricated store shelter , pvc insulated cable copper conductor 1 point 5 sqmm in 90 mtr roll , pvc insulated cable copper conductor 2 point 5 sqmm single core in roll , pvc insulated cable aluminiumconductor 6 sqmm , flexible wire 23 oblique 76 copper conductor , pvc casing capping 25 mm wide 2m long , ms screws 6mm x 19 mm , ms screws 4mm x 19 mm , ms screws 6mm x 40 mm , switch piano type 6 amp , switch and socket combination 5 pin 5 amp with pvc gang box , switch and socket combination 15 amp 5 pin with pvc gang box , main switch 32 amps obelique 240 volt dp , mcb 6 amp sp , mcb 10 amp sp , mcb 32 amp dp , angle holder , led bulb 14 w , led tube light fittings of 20w strip batten fittings complete , ceiling fan complete with blades , bulk head fitting of 18 watt with complete accessories , fr electrical insulation tape , ceiling rose 6 amp pilot 02 plate , change over switch double pole 32 amp , mcb box 6 way spn , rectangular wooden switch board with hylam sheet on top , pvc round block , exhaust fan 450 mm sweep , pvc switch board 6 points , earthing set complete , prefabricated gel earthing electrode of pipe in pipe technology , air termination single pointed copper rod 12mm dia and 300mm long , gi pipe 100mm dia 2 m long medium grade with base plate , back fill compound , ci manhole cover of size 30cm x 30 cm with handles , aluminium strip 25 x 3 mm , gi strip 32 x 6 mm , insulator for fixing down conductors , integral water proofing compound , synthetic enamel paint white colour 1st quality , synthetic enamel paint og colour 1st quality , synthetic enamel paint brown colour 1st quality , red oxide zinc chromate primer for metal surfaces , wooden primer white colour , taurpentine oil , oil bound distemper in off white colour , weather coat exterior emulsion , panting brush 50 mm size , mild steel chromium plated 25mm dia and 3mm thickness , fan hook made of 12 mm ms round bar to be hanged from purlin , ms binding wire 0 point 90mm dia , texture finished gypsum board false ceiling panel , chair office cushion , office table steel , steel racks , pvc chair with arms , mild steel dunnage , de spanner set size all type , hand gloves leather streatcheable with wollen inner first quality , brick trowel steel , mortar pan steel , measuring tape 15m long steel , shoval with plastic handle and plastic d grip and carbon steel blade , axes picks 3 kgs for digging with wooden handle , plier cutting 200mm for barbed wire , mild steel material handling trolley of size 1200mm x 600mm x 300mm , mild steel semi automatic portable concrete vibrator needle , portable concrete mixture machine
Tender For supply, testing of 11 kv aaac triple extruded covered conductor mvcc 1c 70 sqmm xlpe cable, aaac / al-7/ al -59 shielding with semi conducting cross-linked polymer, inner covering with low-density track resistance cross-linked polyethylene (without carbon black), outer covering with high-density uv & track resistance cross-linked polyethylene, extruded semi conductive layer 0.3 mm, with inner insulation of xlpe without carbon black 1.2 mm, outer insulaton with uv & track resistant xlpe 1.1 mm as periec: 61089, is: 398-2iec: 61089, bs en: 50182/50397.make : rr/havells/finolex/kei [ warrantyperiod: 12 months after the date of delivery ] ]
Tender For supply, testing of 11 kv aaac triple extruded covered conductor mvcc 1c 120 sqmm xlpe cable, aaac / al-7/ al -59 shielding with semi conducting cross-linked polymer, inner covering with low-density track resistance cross-linked polyethylene (without carbon black), outer covering with high-density uv & track resistance cross-linked polyethylene, extruded semi conductive layer 0.3 mm, with inner insulation of xlpe without carbon black 1.2 mm, outer insulaton with uv & track resistant xlpe 1.1 mm as per iec: 61089, is: 398-2iec: 61089, bs en: 50182/50397. make : rr/havells/finolex/kei [ warranty period: 12 months after the date of delivery ] ]
Tender For supply & testing of 3 core, 120 sq mm, ht 11 kv (e) cable : stranded compact circular aluminiumconductor, conductor screen with extruded semi conducting compound, xlpe insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up , innersheath of pvc tape, galvanised steel flat strip armoured, and overall pc sheahed cable conforming to is 7098 / (part-ii)1985 with latest amendment. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p
Tender For supply of prefabricated living shelter 06 men , prefabricated living shelter 10 men , living shelter 20 men , ceiling fan 1400 mm , ceiling fan 1200 mm , 1100 v grade pvc insulated copper stranded conductor two core , led panel ceiling light , house service bracket , led tube light fittings 20w , led tube light fittings 40 w , switch socket combination 5 amp 5 pin , switch socket combination 6 amp 5 pin , switch socket combination 15 amp 5 pin , switch socket combination 20 amp 10 pin , piano type switch 6 amp , piano type switch 5 amp , rectangular pvc switch board , led flood light 18 w , fan regulator block for mounting switches , mcb db made of steel sheet , fr insulation tape , mcb 6 amp sp , mcb 10 amp sp , mcb 25 amp spn , pvc ceiling rose 6 amp , pvc casing capping 25 mm , pvc casing capping 32 mm , angle holder with 14w led bulb , pvc round block , pvc rectanular box 250x200x50mm , pvc rectangular box 175x100x50mm , black screws 4mmx19mm , black screws 6mm x 40 mm , 20 watt bulk head fitting , 10 w led flood light , 20 mm pvc conduits with bend , mcb 16 amp with spn , mcb 63aamp with spn , mcb sp 6-32a amp with spn , pvc insulated cable copper conductor 1 point 5 sqmm , pvc insulated cable copper conductor 2 point 5 sqmm , 1100 v grade frpvc insulated of size 1 point 5mm , 1100 v grade frpvc insulated of size 2 point 5mm , flexible pipe 1 inch , angle holder with lamp shed 9w led bulb , main switch 32 amp 240v spn , change over switch 32 amp , pvc square box , pvc innersheathed unarmed cable 10 sqmm two core , hange over switch 63 amp dp , main switch 63 amp with spn , 1100 v grade 3 core frpvc , earthing material , lightening arrestor system , cp cloth hook with six hooks , ms hook for ceiling fan , 25 mm dia drapery rod 1 point 20m , 25 mm dia drapery rod 1 point 05m , fire extinguisher foam 1 kg cap , vitrified coloured floor tiles , looking mirror , ms single bed , ms single bunk bed , ms double bunk bed , steel locker , ms cabinet , wooden table , plastic chair , chromium plated peg set , aluminum peg stay of four hooks , mild steel chromium plated 25 mm dia , 6mm screw 100 mm long , white cement , ms binding wire , turpentine oil , red oxide , weather proof exterior base paint , synthetic enamel paint , brush 4 inch , brush 2 inch , wall putty , cement primer , integral water proofing compound , stainer 200 ml , vitrified double charged floor tiles , anti-skid coloured floor tiles , leak proof compound , non asbestos fibre cement designer board false ceiling , main vertical ms angle of size 60x60x6mm , horizontal ms angle of size 60x60x6mm , galvanised iron wire dia 3 mm length , erection tools , mild steel semi-automatic portable concrete vibrator