Get complete information related to latest Aluminium Anode Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminium Anode Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminium Anode Tenders.
Tender For supply of portable electromagnetic radiation tester , portable optic fiber meter with cleaver cum lan tester , handheld digital oscilloscope , digital insulation tester megger 1000v , digital multimeter , portable water depth sounder , portable anemometer , portable cordless drilling machine , fan blower , electrical tool kit box , heavy item lifter mover tool , electronic component kit , re-work station temp 100 to 450 c with air flow 100cu per min , pcb soldering magnifying glass with led lamp , storage organizer for electronic component , rechargeable emergency light , hot air gun , rechargeable torch light , bench vice with clamp
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - electrical and electronics item at 3 uaam; electrical system or installation, and electronics; bidder
Tender For corrigendum : strengthening of (e/m) equipments of various tube wells installed at babu park kotla area under kasturba nagar constituency ac-42 . - s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.make: - tata/jindal, supply of out door type 7.5 to 10hp hut type electrical feeder pillar/metal board of welded construction of size 1370mm x 760mm x 460mmfabricated with 16 swg m.s. sheet with horizontal and vertical intermediate chamber of suitable size onsuitable size insulating board to make the panel robust, having double door with 14 swg s.s hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, vermin proof having following items.1. mccb 63 amp, 4 pole-1 no2. rccb/elcb 63 amp, 4 pole with earth fault indicator and positive contact indication protecting a circuit automatically 1no3. fully automatic star delta starter of 10hp, 3phase oil immersed type 1no4. digital ampere meter 96mmx96mm square shape of 0-30 amp range 1no5. digital voltmeter of 96mm x 96 mm square shape of 0-500 volt range with selector switch 1no6. led indicating lamps with fitting (a set of 3 lamps) 1set7. shunt capacitor of 5 kvar with three phase isolator 1no8. motor protection assembly having earth leakage protection, phase sequence corrector, single phasing protection, over load protection, high voltage-low voltage protection. 1no9. programmable time switch (i.e. ryb phase & facility to change over from automatic to manual & vice versa) up to 10 h.p.1no10. complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc.as required. the panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame.make:-all the insert used in panel must be of djb approved makes and should be isi marked where make of that equipment is not approved.djb item code 10.2.1, supply of pvc insulated pvc sheathed copper conductor flat cable size 3 core x 4sq mm,1100 volts, confirming to is 694(each roll 100mtr long) make: finolex / havells./kei/any djb approved make., s/o nut bolts,washer dia 1 long full threaded, s/o rubber packing 50 mm dia. flange., lowering and lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t&p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material (rubber packing and nuts bolts) will be arranged by the firm as per site requirement. the other material required during execution will be provided by department.
Tender For auction sale of u/s wooden scrap,u/s mixed plastic drums (20 kg to 60 kg capacity),non woven plastic bag(bccp/bclp),poly propylene & paper bags (pva/cmc/ti02),u/s cotton comber waste briquette,u/s pulp recovered from filter bed,u/s various electrical item- list attached
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For improvement of e/m equipment of various tube wells in c and d block okhla vihar in okhla constituency ac-54. - s/o pvc insulated pvc sheathed flat cable with plain copper conductor having 3 cores for submersible motor of 4 sq mm size (each roll of 100 mtrs.). make: -grandlay/havells/gloster/djb approved, s/o rubber packing 50 mm dia. flange., providing & fixing of indicating lamps ryb along with complete wiring of above electrical equipment and with suitable size copper conductor wire ( 6 sq mm,4 sq mm,2,5 sq mm & 1.5 sq mm) and suitable size ferrule /socket of required size insulating board i/c replacement of old and damaged component s with above mentioned material .job i/c testing & commissioning of complete panel board on load as per site requirement., s/o double flanged g.i pipe of 50 mm dia. medium class each of 3 mtrs long duly threaded on both ends welded and fitted with g.i flange on both ends having the slot for sub cable.djb sor 2024-25 item code 45.1.93. make: - tata/jindal, s/o ms nut bolts off size as per requirement., lowering & lifting of sub/sets from bore by taking out double flanged gi pipes, submersible p/set, cable, cutting of rusted nuts and bolts etc and replacement of damaged d/f gi pipes, cable, defective pump set etc as per site requirement and lowering of sub p/set, sub cable, gi pipe etc as required, jointing of cable from sub p/set along with holding of cable with pipes and jointing of d/f pipes etc with nuts bolts and rubber packing etc. the job includes hiring of all t & p, tripod stand, chain pulley block and other material handling equipments, safety gadgets ad required and consumable material will be arranged by the firm as per site requirement. beyond the depth of 250 feet.djb sor(e&m)-2022 item code 27.1.2