Web Analytics Made Easy - StatCounter

Aluminium Feeder Tenders

Get complete information related to latest Aluminium Feeder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminium Feeder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminium Feeder Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38984681 Due date: 06 Feb, 202506 Feb, 2025 10.00 Lacs
Tender For repair replacement to unsv building earthing, flame proof wiring, old and fatal copper aluminium wiring, replacement to unsv ac metal box, sub main wiring, vtpn db/feeder pillar box and certain e/m works under age (i) ayodhya cantt

CTN :38934541 Due date: 30 Jan, 202530 Jan, 2025 NA
Tender For supply of spares for wdxrf instrument as per annexure oem spares for automobiles, instrument trolley for hospitals (v2), spares for tripper and apron feeder, laparoscopic instrument tray, spares tyre for tyre coupling, aluminium cup for xrf instrument, spare / add on battery packs for transreceiver - handheld, refrigerated centrifuge for general and research purpose, tool kit for vadya yantra(musical instrument)-dholak - o.d.o.p up gov. (amroha), led diving torch light (diving instruments or accessories)

CTN :38900130 Due date: 17 Jan, 202517 Jan, 2025 18.16 Lacs
Tender For replacement of 30 kva diesel generator set and upgradation of old feeder pillar and service connection with xlpe aluminium armoured cables at office cum residential complex at sib, agartala.

Central Government/Public Sector

CTN :38878105 Due date: 30 Jan, 202530 Jan, 2025 NA
Tender For provision of power supply at proposed isolation bay near 05 and 23 end of runway at rupsi airport-1 supplying of following size of 1.1kv grade multistrand aluminium conductor xlpe insulated pvc sheathed armoured power cable (as per is: 7098:1988 with upto date amendments) complete as required. (i) 3.5 core, 300 sqmm. meter 200 (ii) 3.5 core, 95 sqmm. meter 1800 2 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (i) above 185 sq. mm and upto 400 sq. mm meter 146 (ii) above 35 sq. mm and upto 95 sq. mm meter 1755 3 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal/ hdpe pipe as required. (i) above 185 sq. mm and upto 400 sq. mm meter 24 (ii) above 35 sq. mm and upto 95 sq. mm meter 45 4 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required: (i) above 185 sq. mm and upto 400 sq. mm meter 30 5 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required: (i) 3 x 95 sq. mm (45mm) set 2 (ii) 3 x 400 sq. mm (82mm) set 2 6 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930. part ii complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. od 200 mm dia meter 69 design, manufacturing, supply, installation, testing & commissioning of cubicle type totally enclosed double, door, free standing, dust free, damp of vermin proof and water proof outdoor (ip 55) feeder pillar with canopy, fabricated out of 2mm thick crca sheet, epoxy paintained with provision of 3mm gland plate for incoming &, outgoing cables including supply & fixing the following items and interconnections, wiring with suitable size, wires/cables and including all civil works like excavation, pcc, brick work pedestal, plastering, refilling etc. and, as per specifications as required. incomer: 250a 4p 36ka tm mccb with ol/sc protection-2 nos, (i) spreader-2 nos, (ii) extended rotary handle- 2 nos, (iii) 230v uv coil-2 nos, (iv) 1co aux +tac- 2 nos, (v) indicating lamp on , off, trip 230v ac - 6 nos, (vi) phase indicating lamp r , y, b , 230v ac- 6 nos, (vii) 6a , mcb ,sp 10ka- 2 nos, (viii) 250/5, 15va, cl-1, c.t - 6 nos, (ix) 1ph digital volmeter , 230v ac - 2 nos, (x) voltmeter selector switch- 6 nos, (xi) 1ph digital ammeter , 230v ac -2 nos, (xii) ammeter selector switch- 2 nos, (xiii) 2no+2nc auxiliary contactor 220v ac- 2 nos, buscoupler:, 250a 4p 36ka tm mccb with ol/sc protection - 1 no, (i) spreader-1 no, (ii) extended rotary handle- 1 no, (iii) 230v uv coil-1 no, (iv) 1co aux +tac- 1 no, set 1, (v) indicating lamp on , off, trip 230v ac - 3 nos, (vi) 2no+2nc auxiliary contactor 220v ac- 3 nos, outgoing:, 160a 4p 36ka tm mccb with ol/sc protection( active + standby) - 2 nos, (i) spreader-2 nos, (ii) extended rotary handle- 2 nos, outgoing:, 63a 4p 36ka tm mccb with ol/sc protection- 2 nos, (i) extended rotary handle- 2 nos, outgoing:, 32a 4p 36ka tm mccb with ol/sc protection- 1 no, (i) extended rotary handle- 1 no, others:, 3pin plug & socket- 1 no, 8 design, manufacturing, supply, installation, testing & commissioning of cubicle type totally enclosed double door, free standing, dust free, damp of vermin proof and water proof outdoor (ip 55) feeder pillar with canopy fabricated out of 2mm thick crca sheet, epoxy paintained with provision of 3mm gland plate for incoming & outgoing cables including supp

State Government

CTN :38774468 Due date: 30 Jan, 202530 Jan, 2025 29.71 Lacs
Tender For painting of 83nos badly rusted ms towers with one coat of red oxide and one coat of aluminium paint for 132kv k.kota-t.narsapuram dc feeder (01-32) & 132kv t.narsapuram-aswaraopeta dc feeder (34-86) (previously named as 132kv k.kota-aswaraopeta dc feeder) in o&m circle, eluru

State Government

CTN :38828811 Due date: 05 Feb, 202505 Feb, 2025 10.11 Lacs
Tender For painting of badly rusted 220 kv and 132kv cpl structures excluding cpl structures of 132 kv garividi-mor feeder with one coat of red oxide and one coat of aluminium paint at 220/132/33kv substation, garividi in vizianagaram district

corporations/Associations/Others

CTN :38741632 Due date: 20 Jan, 202520 Jan, 2025 NA
Tender For supply of sundry materials transportation earthing arrangements electrification of control room building tp items and furnitures required towards establishment of new 33kv indoor ss at ottiyambakkam arasankazhani village - supply of materials, ms channel 100mm x 50mm, ms angle 65mm x 65mm, ms flat 50 x 8mm, ms rod 40mm dia, 33kv, 1x630 sq.mm, aluminium clamp, 11kv, 1x630 sq.mm, aluminium clamp, rubber mat, plastic name board ( feeder name, lc board, back charged etc.,), 33kv & 11 kv breaker name plate details stickers, first aid box, wall clock, entrance floor mat, welcome mat, schematic layout board ( wooden / plastic / aluminium) having the size of 1200mm x 600 mm and board covered with 3mm thick achorlic transparent sheet., earthing layout board ( wooden / plastic / aluminium) having the size of 1200mm x 600 mm and board covered with 3mm thick achorlic transparent sheet., transportation & labour works, labour charges for transporting the 33kv vcb panel having 2m to 2.5m height and 3m length and weighing of about 3.5 tonne carefully from cdc stores to newly proposed 33/11kv indoor ss at arasankazhani, chennai. including loading and unloading moving safely by use of cranes. this includes moving the package from inside the store shed to its ramp and inside to the substation control room (transformer panel 2 nos., + feeder panel 3 nos + bus coupler and adaptor panel), labour charges for transporting the 11 kv vcb panel having 0.9m width 3m height and 2.5m length and weighing 1.5 tonne carefully from cdc stores at ambattur to newly proposed 33/11kv indoor ss at arasankazhani, chennai. including loading and unloading moving safely by use of cranes. this includes moving the package from inside the store shed to its ramp and inside to the substation control room. (transformer panel 2nos., feeder panel 6 nos., bus coupler and bus adopter), labour charges for marking on the floor and chipping of foundation holes in complete alignment embadding of channel for erection of breaker and grouting the 33kv vcbs., labour charges for marking on the floor and chipping of foundation holes in complete alignment embadding of channel for erection of breaker and grouting the 11kv vcbs, labour charges for drawal of 33kv,1x630 sq.mm, xlpe, ug, cable from cdc stores at ambattur and transporting to work site in lorry and laying the same in side duct from power transformer i & ii to hv breaker i & ii, labour charges for drawal of 11kv,1x630 sq.mm, xlpe, ug, cable from cdc stores at ambattur and transporting to work site in lorry and laying the same in side duct from power transformer i & ii to lv breaker i & ii, labour charges for drawal of 1.1kv armoured copper control cable from cdc stores at ambattur and transporting to work site in lorry and laying the same in side duct on g.i.tray for ss equipments., earthing arrangements, labour charges for drawal of 40dia m.s rod from departmental stores and transporting to worksite inlorry (including loading & unloading) and labour charges for auguring to a depth of 6mtr/20ft and fixing the m.s round rod 40mm dia board supply and making m.s clamping arrangement in top of the rod and 4nos 12mm dia holes in clamp for inter linking of m.s. flats in any kind of soil and fixing with gem and burried in ground and as directed by site in charge. (ground enhancement material to be supplied by the contractor )(6m x 12nos = 72mts), labour charges for drawal of m. s. flat of size. 50mm x 8mm from departmental stores and transporting to worksite in lorry (including loading & and unloading) and labour charges for laying, cutting welding and painting of ms flat of size 50 x 8 mm and interconnecting . the plate should be burried at a depth of 2 feet depth or laid in duct as per site condition and clamped out one meter interval. m.s flat will be supplied by the board and painted with twin coat redoxide and enamal green paint before laying and as directed by site in charge. (as per drg.), fabricati

CTN :38872067 Due date: 30 Jan, 202530 Jan, 2025 NA
Tender For supply of all aluminium 25 kv feeder/return conductor (single spider) 19/3.99 mm aluminium co nductor spider has been used as cross along track feeder and return conductor. the spider conductor to be used as cross feeder as per is: 398(part-1) 1996. [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :38791963 Due date: 20 Jan, 202520 Jan, 2025 NA
Tender For supply of aii aluminum 25 kv feeder/return conductor (single spider)19/3.99 mm aluminium conducttr ( spider) to be used as cross along track feeder and return conductor. the spid er conductor to be used as cross feeder. as per is 398-1 (b) (1996) [ warranty period: 30 mont hs after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up