Web Analytics Made Easy - StatCounter

Aluminum Counter Tenders

Get complete information related to latest Aluminum Counter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminum Counter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminum Counter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43830952 Due date: 13 Feb, 202613 Feb, 2026 NA
Tender For supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volume control dampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning of fire damp

Central Government/Public Sector

CTN :43775222 Due date: 19 Feb, 202619 Feb, 2026 1.45 Crore
Tender For supply of supply of hot dip galvanized octagonal street light pole of 7 mtrs length , supply of outdoor type 100w led type flood light luminaire , supply of outdoor type 90w led streetlight luminaire , design, fabrication, supply, installation, testing and commissioning of cubicle type, outdoor type feeder pillar panel , sitc of lt feeder pillar panel , supply power cable of 3. 5 x 50 sq. mm sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 4 x 16 sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 3. 5 x 300 sqmm. , supply of 50 mm od hdpe pipe of pe 80 pn 6 isi marked , supply of 63 mm od hdpe pipe of pe 80 pn 6 , supply of 110 mm od hdpe pipe of pe 80 pn 6 , supply of underground warning or caution tape size 6 x 250 mtr , supplying and making end termination 3. 5 x 50 sq. mm , supplying and making end termination 4 x 16 sq. mm , supplying and making end termination 3. 5 x 300 sq. mm , excavation for cable trenches in soft soil , laying of upto 63 mm dia size dwc or hdpe pipe , laying of 110 mm dia size dwc or hdpe pipe , laying of cable up to 35 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 35 sq. mm and upto 95 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 185 sq. mm and upto 400 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying and fixing of cable above 185 sq. mm and upto 400 sq. mm on wall surface , supplying and making of straight through joint with heat shrinkable kit 3. 5 x 300 sq. mm , dismantling bituminous road by manually or mechanical , supply and fixing of single arm bracket having arm length of 1. 2 mtr , supply and fixing of double arm bracket having arm length of 1. 2 mtr , supply of dp mcb, 6 a, c curve , supplying 3 core 1. 5 sqmm of frls pvc round sheathed copper conductor industrial cable , erection of metallic pole upto 7 mtr length including rcc foundation , installation, testing, and commissioning of 90w led type street light fixture , installation, testing, and commissioning of 100w led type flood light fixture , earthing with g. i. earth pipe 4. 5 meter long, 40 mm dia including accessories , providing and fixing 6 swg dia g. i. wire , providing and fixing 25 mm x 5 mm g. i. strip in 40 mm dia g. i. pipe , providing and laying in position cement concrete , dismantling of existing street light poles up to 9 meters , supply and erection of extra supporting ms structure with l channel , laying of caution tape over the cable trench
 Loading, Please wait...

Connect us via What's Up