Tender For supply of ms fabricated office cabin of size 6feet by 6feet by 8.5feet lbh with necessary electrical fittings , rack size 6 feet , wall fan , aluminumslidingwindow with safety grill 4feet by 3feet , door 6 feet by 3feet , led tube light , switch and socket
Tender For corrigendum : aluminium extruded section - aluminium extruded section, al panel mouldingi.d. no 5519 length 5000 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 63400, temper m drawings 1-01-21-167/3 dtd.10.05.2016, al fluted anglei.d. no 2007 length 4000 mmbis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp drawings 1-01-21-167/2 dtd.10.05.2016, grab rail socket sectioni.d. no 9638 length 5000 mmbis 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 63400 temper wp ,drawings 1-01-21-167/1 dtd.10.05.2016, gutter mouldingi.d. no 6250 length 4270 mmbis 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 63400 temper mdrawing 1-01-21-167/4(b) dtd.24.06.2024, step edging angle id no.5701, length 4000 mm, bis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,, alloy 64430, temper wp, drg.no. 1-01-21-167/3dtd.10.05.2016, volvo type aluminium decorative section 2" , size : 5000 mm drawing no.1-03-21-226 dtd.04.08.2014is 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 63400, temper m(1mtr. = 0.270 kg.), volvo type aluminium decorative section 1" , size : 5000 mm is:733 of 1983 (reaffirmed 2022 ) & its amendments from time to time.alloy 63400, temper m drawing no.1-03-21-226 (1 mtr.=0.036 kg), z sectioni.d. no 3402 length 3660 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp , drawings 1-01-21-167/2 dtd.10.05.2016, al angle i.d. no 1756 length 4500 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp , drawings 1-01-21-167/1 dtd.10.05.2016, al anglei.d. no 1904 length 3660 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 64430 temper wp, drawings 1-01-21-167/1 dtd.10.05.2016, al angle sole bari.d. no 1758 length 4500 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp ,drawings 1-01-21-167/1dtd.10.05.2016, al luggage carrier flooring sectioni.d. no 7259 length 2850 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 64430 temper wp , drawings 1-01-21-167/4(b) dtd.24.06.2024, al extruded section for window glassi.d. no 3987,length 2000 mm is 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 63400 temper wp ,drawings 1-01-21-167/3 dtd.10.05.2016, al section for window glass framei.d. no 3987 length 3330 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 63400 temper wp , drawings 1-01-21-167/3 dtd.10.05.2016, al roof mouldingi.d.no 6354 length 2780 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 63400 temper m , drawings 1-01-21-167/3 dtd.10.05.2016, al top hat sectioni.d. no 2654 length 2070 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp , drawings 1-01-21-167/2 dtd.10.05.2016, al top hat sectioni.d. no 2654 length 2150 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp , drawings 1-01-21-167/2 dtd.10.05.2016, al top hat sectioni.d. no 2654 length 2200 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 64430 temper wp ,drawings 1-01-21-167/2 dtd.10.05.2016, al top hat sectioni.d. no 2654 length 2220 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp ,drawings 1-01-21-167/2 dtd.10.05.2016, al top hat sectioni.d. no 2654 length 2275 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp ,drawings 1-01-21-167/2 dtd.10.05.2016, al top hat sectioni.d. no 2654 length 2870 mmis 733/ 1983(reaffirmed 2022)& its amendments from time to time., alloy 64430 temper wp , drawings 1-01-21-167/2 dtd.10.05.2016, al top hat sectioni.d. no 2654, length 4300 mm is 733/ 1983(reaffirmed 2022)& its amendments from time to time.,alloy 64430 temper wp , dra
Tender For corrigendum : supply of repairing work of heating conditioning chamber make: grover (capb) : - control panel for grover, inclu , repairing work of ac conditioning chamber make: voltas window (capb) : - service charges, gas charging , repairing work of heating conditioning chamber of (wapb) electric control panel, installation charg
Tender For supply, installation, testing and commissioning of extra material for installation of unitary acs in different departments /centers/schools, office etc. at iit kharagpur, kharagpur (phase i). - "supply, installation, testing and commissioning including vaccumization and nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for split ac system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with xple class-o tubular insulation/with class-o closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required :note: wall opening and making good to the damages.", "6.4 mm (¼"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "9.5 mm (⅜"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "12.7 mm (½"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "15.86 mm ( ⅝"") dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", "19 mm (¾"")dia (od) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation", interconnection electrical copper cables from indoor , outdoor & electrical control panel complete with 4 core 2.5 sqmm copper frls insulated cable(isi marked) with cable tie & clamp etc as required., supply & installation m.s epoxy painted fabricated stand for different size condensing unit with vibration isolators, grouting, for complete platform type stand for outdoor unit having safety railing etc as per site requirement., supply & installation of upvc drain pipe (isi marked) with 6mm thick nitrile rubber insulation from idu - 25mm dia, 40 mm rigid upvc drain pipe (isi marked) with 6 mm thick nitrile rubber insulation complete with fittings, u traps etc. & as specified to the nearest toilet with required civil works & finishing the same., supply of r-22 gas for top up, supply of r-32 gas for top up, supply & installation of good quality wooden frame (2" x 2") thick required for window ac installation, supply & installation of 16amps plug top (isi marked), supply & installation of 100mm pvc trunking with snap on trunking (isi marked), "supplying and installing following size of perforated hot dipped galvanised iron cable tray with cover (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.", 100 mm width x 50 mm depth x 1.6 mm thickness, 225 mm width x 50 mm depth x 1.6 mm thickness, 300 mm width x 50 mm depth x 1.6 mm thickness, installation, testing & commissioning of the window ,split acs ,cassette ac supplied by department. price shall be inclusive of installtion upto 3mtr of refrigerant pipe, drain pipe and cable., window acs, split acs, cassette acs, tower acs, reinstallation, lifting, shifting of existing ac units (split & window acs & cassette ac)., window acs, split acs, cassette acs, tower acs, dismantling of existing ac (split ac / window ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (cassette ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, dismantling of existing ac (tower ac) units including all copper pipes, drain pipes mounting surfaces, etc. complete and keeping the premises clear of all and shifting to rac work shop, buy-back of existing unserviceable ac (split ac / window ac/cassette ac) units(all type) including all copper pipes, drain pipes mounting surfaces, etc. complete. the item shall be quoted as negat