Get complete information related to latest Amf Control Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amf Control Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amf Control Panel Tenders.
Tender For augmentation work of transformer, vcb, pmcc panel, cable, etc electrical items and constrctuction vcb room with 02 years comprehensive maintaince at aji dam site pumping station
Tender For corrigendum : supply, installation, testing and commissioning of 400 kva, 3 phase, 415v water cooled silent type diesel generator set including all accessories with amfcontrolpanel at pandu pokhar - rajgir and papharni talab - mandar, banka.
Tender For supply, fixing, installation and commissioning including suitable foundation of three phase 415 volts diesel generating sets with amfcontrolpanel of capacity 125 kva similar to kirloskar. detailed specification enclosed. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of revolving chair with front pivot synchro tilt mechanism , executive table with keyboard tray and pedestal side storage unit executive table 7x4x2.5 mdf , office chair non revolving and non tilting chair with armrest wooden chair , 5 seater sofa with leatherite cover geeken , modular table with glass table top and pedestal engineer wood understructure bloom coffee table , single storage side table h 650 mm x d 500 mm , cooling and heating 2 ton 3 star iseer value from 3.8 to 4.39 inverter ac variable speed wall mount split ac , door curtains of gsm 240 , crown stainless steel 304 curtain rod pipe and mounting bracket length 5 meter curtain rod19mm with bracket meter , wooden almirah wardrobe without mirror with na shelves , wooden book case made up of three layer prelaminated particles board wood product of grade ii type ii of is 12823 latest and 8 shelves , single wooden bed with headboard only , spring mattress dimensions 1905 mm x 889 mm pocket spring 75 x 35 x 8 , revolving chair with tilt working with torsion bar mechanism , metal dial and hands wall clocks , modular extendable conference table with provision for pedestal table top wood engineer wood understructure , revolving chair with synchronic tilt mechanism , wooden almirah wardrobe without mirror with 2 shelves local 6x3 , door curtains of gsm 250 , seat only chair count 3 , executive table with pedestal side storage unit executive table 1500x750x750mm , executive table with keyboard tray and pedestal side storage unit asd 2 , executive table , computer table with additional unit , cantilever chair non revolving and non tilting chair with armrest , non revolving and non tilting chair without armrest , 3 seater sofa with fabric cover , cafeteria chair without armrest , modular table with particle board table top and wooden engineer wood understructure , modular table with particle board table top and metal understructure round revolving table , cooling and heating 1.5 ton 3 star iseer value from 3.8 to 4.3 inverter ac variable speed wall mount split ac , power generator dg set of 25 amfcontrolpanel , led surface light 2x2 36 watt led surface light 2x2 , outdoor twin waste bin of capacity 120 , stainless steel waste container and acceseris domestic 8 ltr.capacity , wooden wall panelling , wooen ceiling , wooden flooring , pvc wall panelling , pvc false ceiling
Tender For bid to ras tender for supply of rate contract for sitc of 8 nos 20 kva dea set with sound proof canopy and amfcontrolpanel with remote controlling and monitoring for various sites under bsnl electrical zone, meerut
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in controlpanel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amfpanel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amfcontrolpanel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply, inst., testing and comm. of 35 kva/26 kw cpcb iv, diesel generator set with amfcontrolpanel to be installed at govt. college of nursing at ngp in the dist. of ngp (building)